1、 DEUTSCHE NORMMay 2006DIN EN 14959 ICS 61.040 Supersedes: see below Touch and close fasteners Determination of resistance to fraying after washing English version of DIN EN 14959:2006-05 Haftverschlsse Bestimmung der Kantenschnittfestigkeit nach dem Waschen Englische Fassung DIN EN 14959:2006-05 Ers
2、atzvermerk Together with DIN EN 1414:2000-10, DIN EN 12241:1999-12, DIN EN 12242:1999-12 and DIN EN 12243:1999-12 supersedes DIN 3415-2:1990-06, withdrawn 1997-01 Document comprises 11 pages No part of this standard may be reproduced without prior permission of DIN Deutsches Institut fr Normung e. V
3、., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany, has the exclusive right of sale for German Standards (DIN-Normen). English price group 7 www.din.de www.beuth.de !,nh2“10.06 9756915DIN EN 14959:2006-05 2 National foreword This standard has been prepared by CEN/TC 248 Textiles and textile product
4、s (Secretariat: United Kingdom). The responsible German body involved in its preparation was the Normenausschuss Textil und Textilmaschi-nen (Textilnorm) (Textiles and Textile Machinery Standards Committee), Technical Committee 106-01-06 AA Haftverschlsse (formerly TEX/CEN-HV). Amendments This stand
5、ard differs from DIN 3415-2:1990-06 (withdrawn January 1997) as follows: a) The standard has been completely revised and brought in line with the state of the art and, was split up into several standards. b) The normative references have been supplemented. c) The preparation of test specimens and th
6、e procedure of the test method have been amended. Previous editions DIN 3415-2: 1990-06 EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14959February 2006ICS 61.040English VersionTouch and close fasteners - Determination of resistance tofraying after washingFermetures auto-agrippantes - Dterminati
7、on de larsistance leffilochage aprs lavageHaftverschlsse - Bestimmung der Kantenschnittfestigkeitnach dem WaschenThis European Standard was approved by CEN on 30 December 2005.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this Eur
8、opeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English,
9、French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Repu
10、blic, Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NOR
11、MALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2006 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14959:2006: EEN 14959:2006 (E) 2 Contents Page Foreword3 1 Scope 4 2 Normative refere
12、nces 4 3 Principle4 4 Apparatus .4 5 Test specimen4 6 Conditioning.5 7 Procedure .5 8 Test report 5 Bibliography 9 EN 14959:2006 (E) 3 Foreword This European Standard (EN 14959:2006) has been prepared by Technical Committee CEN/TC 248 “Textiles and textile products”, the secretariat of which is held
13、 by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by August 2006, and conflicting national standards shall be withdrawn at the latest by August 2006. According to the CEN/CENELEC Internal Regu
14、lations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, N
15、orway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 14959:2006 (E) 4 1 Scope This European Standard specifies a method for determining the resistance to fraying of touch and close fasteners. 2 Normative references The following referenced documents
16、 are indispensable for the application of this European Standard. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12241, Touch and close fasteners Method for closure prior to washing an
17、d drying or dry cleaning EN ISO 139, Textiles Standard atmospheres for conditioning and testing (ISO 139:2005) EN ISO 6330, Textiles Domestic washing and drying procedures for textile testing (ISO 6330:2000) 3 Principle In order to measure its resistance to fraying, the male or female component is c
18、ut along its longitudinal axis, sewn on a fabric, on three of its edges (as shown in Figure 1), then assembled with its male or female counterpart (as shown in Figure 2), using the roller specified in EN 12241, then washed according to the specified procedure described in EN ISO 6330. 4 Apparatus 4.
19、1 Long pair of scissors to cut the samples at a length of 50 mm in one stroke. 4.2 Loading fabric, polyester/cotton (50 %/50 %) 130 g/m2. 4.3 Washing machine as specified in EN ISO 6330. 4.4 A metal roller as specified in EN 12241. 5 Test specimen Cut a specimen of male or female tape, to be tested
20、for resistance to fraying, of 50 mm length. Cut a specimen of the male or female counterpart of same width, of 70 mm length. Cut a specimen of loading fabric, of 75 mm length and of width equal to the width of the sample of tape to be tested plus 25 mm. EN 14959:2006 (E) 5 6 Conditioning Condition t
21、he test specimens for a minimum of 24 h in accordance with the standard temperate atmosphere for testing as specified in EN ISO 139. The closing, the drying, the evaluation of the test specimens for resistance to fraying, shall also take place under these conditions. 7 Procedure Cut the specimen of
22、male or female tape to be tested, on a length of 50 mm, taking care to cut at an angle of 90 to its longitudinal axis. Cut the specimen along its longitudinal axis, in one stroke, with a long pair of scissors (4.1). Once the cutting is completed, check the absence of loose filaments, along the longi
23、tudinal cut edge. In case of the presence of loose fibres, the sample has to be eliminated and the sampling repeated. The three cut edges have to be free of loose elements. Sew this specimen on the fabric on the two longitudinal edges and one transversal edge, as shown in Figure 1, following the dis
24、continuous lines. Complete the sewing with 3 stitches per cm at 1,5 mm from the edge of the tape, using a needle number 0,80, with a polyester yarn 30 tex. In order to simulate the closure in usage, position the counterpart of the male or female tape, on top of the tape to be tested (see Figure 1).
25、Use the metal roller (4.4) to close the samples. The roller will be chosen according to the effective width of the tape to be tested after it had been cut along its longitudinal axis. Traverse the metal roller along the closure in one direction then immediately reverse in the other direction. Put th
26、e combined specimen in the loading bag, in order to protect it during washing. Put the loading bag in the washing machine (4.3), then complete the washing, according to the specified cycle in EN ISO 6330. After washing, allow the specimen to dry 24 h in the standard temperate atmosphere defined in E
27、N ISO 139. Separate and close the touch and close fastener, by hand, five times. The fraying will be evaluated by counting the number of loose filaments still attached to the four edges of the tape. 8 Test report The test report shall contain the following information: a) number and date of this Eur
28、opean Standard, i.e. EN 14959:2006; b) date of the test; c) identification of the touch and close fastener; d) any deviation from this European Standard and any incident likely to have affected the results. e) result of the evaluation for fraying. EN 14959:2006 (E) 6 Dimensions in millimetres 501 23
29、4567075W/2 W/2 + 25WKey 1 sample of loading fabric 2 tape to test for fraying 3 tape counterpart on top of sample to test for fraying 4 two transversal edges cut with scissors 5 one longitudinal edge cut with scissors 6 sewing lines W is the original width of the tape to be tested for fraying, befor
30、e being cut along its longitudinal axis (edge 5 on the figure). (on the figure, W is showing the width of the counter part to be positioned on top of the tape to be tested. W is also the width of the closure) W/2 is the width of the tape to test for fraying, after it has been cut along its longitudi
31、nal axis, (edge 5 on the figure). W/2 + 25 mm is the width of the loading fabric Figure 1 Top view of test specimen EN 14959:2006 (E) 7 Dimensions in millimetres 312507570Key 1 counterpart 2 tape to test for fraying attached by sewing to the loading fabric 3 loading fabric Figure 2 Side view of test
32、 specimen before the counterpart is assembled with the tape to be tested for fraying EN 14959:2006 (E) 8 1Key 1 example of loose fibres Figure 3 Example of loose filaments separated from the edges EN 14959:2006 (E) 9 Bibliography 1 EN 12240, Touch and close fasteners Determination of the overall and effective widths of tapes and the effective width of a closure 2 EN ISO 15797, “Textiles - Industrial washing and finishing procedures for testing of workwear (ISO 15797:2002)“