1、October 2012 Translation by DIN-Sprachendienst.English price group 26No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).IC
2、S 13.220.50; 91.060.50!$x“1919885www.din.deDDIN EN 15269-3Extended application of test results for fire resistance and/or smokecontrol for door, shutter and openable window assemblies, includingtheir elements of building hardware Part 3: Fire resistance of hinged and pivoted timber doorsets andopena
3、ble timber framed windows;English version EN 15269-3:2012,English translation of DIN EN 15269-3:2012-10Erweiterter Anwendungsbereich von Prfergebnissen zur Feuerwiderstandsfhigkeitund/oder Rauchdichtigkeit von Tren, Toren und Fenstern einschlielich ihrerBaubeschlge Teil 3: Feuerwiderstandsfhigkeit v
4、on Drehflgeltren und Fenstern aus Holz;Englische Fassung EN 15269-3:2012,Englische bersetzung von DIN EN 15269-3:2012-10Application tendue des rsultats dessais de rsistance au feu et/ou dtanchit lafume des blocs-portes, blocs-fermetures et fentres, y compris leurs lments dequincaillerie Partie 3: Rs
5、istance au feu des blocs-portes battants et pivotants en bois et des fentres ossature bois;Version anglaise EN 15269-3:2012,Traduction anglaise de DIN EN 15269-3:2012-10www.beuth.deIn case of doubt, the German-language original shall be considered authoritative.Document comprises 76 pages 09.12 DIN
6、EN 15269-3:2012-10 2 A comma is used as the decimal marker. National foreword This standard has been prepared by Technical Committee CEN/TC 127 “Fire safety in buildings” (Secretariat: BSI, United Kingdom). The responsible German body involved in its preparation was the Normenausschuss Bauwesen (Bui
7、lding and Civil Engineering Standards Committee), Working Committee NA 005-52-05 AA Brandverhalten von Bau-stoffen und Bauteilen Feuerschutz- und Rauchschutzabschlsse (Spiegelausschuss zu CEN/TC 127/WG 3 sowie Teilbereichen von CEN/TC 127/WG 7, CEN/TC 33 und ISO/TC 92/SC 2). EUROPEAN STANDARD NORME
8、EUROPENNE EUROPISCHE NORM EN 15269-3 August 2012 ICS 13.220.50; 91.060.50 English Version Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part3: Fire resistance of hinged a
9、nd pivoted timber doorsets and openable timber framed windows Application tendue des rsultats dessais de rsistance au feu et/ou dtanchit la fume des blocs-portes, blocs-fermetures et fentres, y compris leurs lments de quincaillerie - Partie 3 : Rsistance au feu des blocs-portes battants et pivotants
10、 en bois et des fentres ossature bois Erweiterter Anwendungsbereich von Prfergebnissen zur Feuerwiderstandsfhigkeit und/oder Rauchdichtigkeit von Tren, Toren und Fenstern einschlielich ihrer Baubeschlge - Teil 3: Feuerwiderstandsfhigkeit von Drehflgeltren und Fenstern aus Holz This European Standard
11、 was approved by CEN on 16 June 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such n
12、ational standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own la
13、nguage and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Gree
14、ce, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG
15、Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15269-3:2012: EEN 15269-3:2012 (E) 2 Contents Page Foreword 31 Scope 42 Normative references 43 Terms and definitions .54 Det
16、ermination of the field of extended application 64.1 General 64.2 How to use the extended application rules in Annex A .64.3 Procedure for maximum field of extended application .64.4 Analysis of test results .75 Extended application report .76 Classification report 7Annex A (normative) Construction
17、parameter variations 9Annex B (normative) Arrangements for doorsets incorporating side and/or overpanels . 70DIN EN 15269-3:2012-10 EN 15269-3:2012 (E) 3 Foreword This document (EN 15269-3:2012) has been prepared by Technical Committee CEN/TC 127 “Fire safety in buildings”, the secretariat of which
18、is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2013, and conflicting national standards shall be withdrawn at the latest by February 2013. Attention is drawn to the possi
19、bility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade A
20、ssociation. This document is one of a series entitled “EN 15269, Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware” which consists of the following parts: Part 1: General requi
21、rements; Part 2: Fire resistance of hinged and pivoted steel doorsets; Part 3: Fire resistance of hinged and pivoted timber doorsets and openable timber framed windows; Part 4: Fire resistance of hinged and pivoted glass doorsets; Part 5: Fire resistance of hinged and pivoted, metal framed, glazed d
22、oorsets and openable windows; Part 6: Fire resistance of sliding timber doorsets; Part 7: Fire resistance of sliding steel doorsets; Part 8: Fire resistance of horizontally folding timber doorsets; Part 9: Fire resistance of horizontally folding steel doorsets; Part 10: Fire resistance of steel roll
23、ing shutter assemblies; Part 11: Fire resistance of operable fabric curtains; Part 20: Smoke control for hinged and pivoted steel, timber and metal framed glazed doorsets. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to
24、implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Rom
25、ania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 15269-3:2012-10 EN 15269-3:2012 (E) 4 1 Scope This European Standard covers hinged or pivoted doorsets with timber based leaves, timber framed glazed doors and openable timber framed windows. It prescribes th
26、e methodology for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1. This standard covers doorsets with internal structural elements which are comprised of timber. Subject to the completion of the appropriate test or tests, the ext
27、ended application may cover all or some of the following examples: integrity (E), integrity/radiation (EW) or integrity/insulation (EI1or EI2) classification; glazed elements including vision panels and framed glazed doorsets, louvres and/or vents; side, transom or overpanels; items of building hard
28、ware; decorative finishes; intumescent, smoke, draught or acoustic seals; alternative supporting construction(s). The effect on the Classification C for the doorsets following an extended application process is not addressed in this European Standard. 2 Normative references The following documents,
29、in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 179, Building hardware Emerge
30、ncy exit devices operated by a lever handle or push pad, for use on escape routes Requirements and test methods EN 844 (all parts), Round and sawn timber Terminology EN 1125, Building hardware Panic exit devices operated by a horizontal bar, for use on escape routes Requirements and test methods EN
31、1363-1, Fire resistance tests Part 1: General requirements EN 1634-1, Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware Part 1: Fire resistance test for doors, shutters and openable windows EN 1634-2, Fire resistance and smoke
32、control tests for door, shutter and openable window assemblies and elements of building hardware Part 2: Fire resistance characterisation test for elements of building hardware EN 12519, Windows and pedestrian doors Terminology DIN EN 15269-3:2012-10 EN 15269-3:2012 (E) 5 EN 13501-2, Fire classifica
33、tion of construction products and building elements Part 2: Classification using test data from fire resistance tests excluding ventilation services EN 15254-4 Extended application of results from fire resistance tests Non-loadbearing walls Part 4: Glazed constructions EN 15269-1:2010, Extended appl
34、ication of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware Part 1: General Requirements EN ISO 13943, Fire safety Vocabulary (ISO 13943) 3 Terms and definitions For the purposes of this document, th
35、e terms and definitions given in EN 1363-1, EN 12519, EN ISO 13943, EN 1634-1, EN 1634-2 and EN 15269-1 and the following apply. 3.1 core material fitted centrally within the thickness of a door leaf which may consist of a single sheet of material or a combination either of sheets of the same materi
36、al or layers of different materials 3.2 effective rebate depth dimension of the door leaf thickness of overlapping adjacent edges of door leaf relative to the door frame, transom or side panel or flush overpanel Note 1 to entry: At the meeting edges and for rebated leaves this dimension will be the
37、rebate where the intumescent seal is fitted or, if no seal is fitted, the depth of the largest rebate (see Figure 1). 3.3 leaf symmetry construction of a door leaf, without consideration of any leaf edge rebates, viewed either side of an imaginary plane drawn centrally in the thickness of the leaf N
38、ote 1 to entry: A symmetrical door leaf will be identical either side of this imaginary plane, whilst an asymmetrical door leaf will differ. 3.4 exposed intumescent seal intumescent seal which is fitted in the perimeter of the leaf or in the door frame rebate and is visible when the leaf is in the o
39、pen position 3.5 concealed intumescent seal intumescent seal which is fitted in the perimeter of the leaf or in the door frame rebate and is not visible when the leaf is in the open position, including seals behind veneers and laminates 3.6 facing (and decorative facing) outer layer of material on t
40、he leaf or panel normally only used for decorative, not for structural, purposes 3.7 subfacing layer (or layers) of material between the core and the facing in the leaf or panel normally used for structural purposes DIN EN 15269-3:2012-10 EN 15269-3:2012 (E) 6 4 Determination of the field of extende
41、d application 4.1 General 4.1.1 Before there can be any consideration for extended application, a representative doorset shall have been tested in accordance with EN 1634-1 to achieve a test result which could generate a classification in accordance with EN 13501-2 at least equal to the classificati
42、on subsequently required from extended application considerations. 4.1.2 A review of the doorset construction parameters can indicate that one or more characteristics may be improved by a particular parameter variation. All evaluations shall be made on the basis of retaining the classifications obta
43、inable from testing to EN 1634-1, including those lower than the test duration. However, this shall never lead to an increased classification for any specific parameter beyond that achieved during any one test, unless specifically identified in the relevant Construction Parameter Variation tables. 4
44、.1.3 If, when following the extended application procedure, any part of the classified product cannot be covered by the extended application rules then that part shall be omitted from the subsequent extended application report and classification report. 4.2 How to use the extended application rules
45、in Annex A 4.2.1 Identify the variations from the original test specimen(s) which are required to be covered by an extended application report. 4.2.2 Locate the variations in the appropriate parameter variation by reference to columns (1) and (2) of Annex A. 4.2.3 Review the type of classification t
46、o be retained from column (3) of Annex A and establish from the contents of column (4) of Annex A whether any extended application is available beyond the direct application rules in EN 1634-1 without the need for further testing. 4.2.4 Where this is deemed to be possible, it can be recorded in the
47、extended application report together with any appropriate restrictions and the stated rules from column (4) of Annex A. 4.2.5 Where the variations required can only be achieved from additional testing, the additional test can be made on a similar specimen type i.e. a doorset of the same or more oner
48、ous configuration where the leaf construction is fundamentally the same as that tested. Alternatively, column (5) of Annex A identifies an option for alternative testing and relevant test parameters. 4.3 Procedure for maximum field of extended application 4.3.1 It is possible to provide an extended field of application from a single test. However, where a manufacturer envisages to manufacture a range of door
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1