1、February 2015 Translation by DIN-Sprachendienst.English price group 13No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).I
2、CS 91.140.70!%“2296159www.din.deDDIN EN 16146Sanitary tapware Extractable shower hoses for sanitary tapware for supply systemstype 1 and type 2 General technical specification;English version EN 16146:2012+A1:2014,English translation of DIN EN 16146:2015-02Sanitrarmaturen Ausziehbare Brauseschluche
3、fr Sanitrarmaturen fr Wasserversorgungssysteme vomTyp 1 und Typ 2 Allgemeine technische Spezifikation;Englische Fassung EN 16146:2012+A1:2014,Englische bersetzung von DIN EN 16146:2015-02Robinetterie sanitaire Flexibles de douchettes extractibles pour robinetterie sanitaire pour les systmesdalimenta
4、tion en eau de types 1 et 2 Spcifications techniques gnrales;Version anglaise EN 16146:2012+A1:2014,Traduction anglaise de DIN EN 16146:2015-02SupersedesDIN EN 16146:2013-03www.beuth.deDocument comprises 27 pagesIn case of doubt, the German-language original shall be considered authoritative.01.15DI
5、N EN 16146:2015-02 2 A comma is used as the decimal marker. National foreword This document (EN 16146:2012+A1:2014) has been prepared by Technical Committee CEN/TC 164 “Water supply” (Secretariat: AFNOR, France). The responsible German body involved in its preparation was the DIN-Normenausschuss Arm
6、aturen (DIN Standards Committee Valves), Working Committee NA 003-02-01 AA Sanitrarmaturen. Amendments This standard differs from DIN EN 16146:2013-03 as follows: a) Amendment A1:2014 has been incoporated: Tables 1 and 3 have been modified. Previous editions DIN EN 16146: 2013-03 EUROPEAN STANDARD N
7、ORME EUROPENNE EUROPISCHE NORM EN 16146:2012+A1 November 2014 ICS 91.140.70 Supersedes EN 16146:2012English Version Sanitary tapware - Extractable shower hoses for sanitary tapware for supply systems type 1 and type 2 - General technical specification Robinetterie sanitaire - Flexibles de douchettes
8、 extractibles pour robinetterie sanitaire pour les systmes dalimentation en eau de types 1 et 2 - Spcifications techniques gnrales Sanitrarmaturen - Ausziehbare Brauseschluche fr Sanitrarmaturen fr Wasserversorgungssysteme vom Typ 1 und Typ 2 - Allgemeine technische Spezifikation This European Stand
9、ard was approved by CEN on 10 November 2012 and includes Amendment 1 approved by CEN on 9 September 2014.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration
10、. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by t
11、ranslation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Fi
12、nland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZA
13、TION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2014 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16146:2012+A1:2014 EEN 16146:2012+A1:2014 (E)
14、2 Contents Page Foreword 4 Introduction .5 1 Scope 6 2 Normative references 8 3 Terms and definitions .9 4 Designation 9 5 Marking .9 6 Materials .9 6.1 Chemical and hygienic requirements 9 6.2 Exposed surface condition and quality of coating 9 7 Dimensional characteristics 10 7.1 General . 10 7.2 C
15、onnecting dimensions . 10 7.3 Special cases 11 8 Hydraulic characteristics . 11 8.1 General . 11 8.2 Flow rate 11 8.2.1 Test method . 11 8.2.2 Principle . 11 8.2.3 Apparatus 12 8.2.4 Procedure 12 8.2.5 Requirements 12 9 Mechanical and leaktightness characteristics 13 9.1 General . 13 9.2 Tensile str
16、ength 13 9.2.1 Test method . 13 9.2.2 Principle . 13 9.2.3 Apparatus 13 9.2.4 Procedure 14 9.2.5 Requirements 14 9.3 Flexing durability test . 14 9.3.1 Test Method . 14 9.3.2 Principle . 14 9.3.3 Apparatus 14 9.3.4 Procedure 15 9.3.5 Requirement 16 9.4 Durability test 16 9.4.1 Test Method . 16 9.4.2
17、 Principle . 16 9.4.3 Apparatus 16 9.4.4 Procedure 16 9.4.5 Requirement 16 9.5 Pressure resistance at elevated temperature 17 9.5.1 Test method . 17 9.5.2 Principle . 17 9.5.3 Apparatus 17 DIN EN 16146:2015-02 EN 16146:2012+A1:2014 (E) 3 9.5.4 Procedure . 18 9.5.5 Requirements . 19 9.6 Thermal shock
18、 test 19 9.6.1 Test method . 19 9.6.2 Principle 19 9.6.3 Apparatus . 19 9.6.4 Procedure . 20 9.6.5 Requirements . 20 10 Rotary connection . 20 10.1 General . 20 10.2 Test Method . 20 10.2.1 Principle 20 10.2.2 Apparatus . 20 10.2.3 Procedure . 21 10.2.4 Requirements . 21 Annex A (informative) Pressu
19、re take-off tee 22 Bibliography 25 DIN EN 16146:2015-02 EN 16146:2012+A1:2014 (E) 4 Foreword This document (EN 16146:2012+A1:2014) has been prepared by Technical Committee CEN/TC 164 “Water supply”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a nati
20、onal standard, either by publication of an identical text or by endorsement, at the latest by May 2015, and conflicting national standards shall be withdrawn at the latest by May 2015. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent right
21、s. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document includes Amendment 1 approved by CEN on 9 September 2014. This document supersedes EN 16146:2012. The start and finish of text introduced or altered by amendment is indicated in the text
22、by tags !“. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia,
23、 France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. DIN EN 16146:2015-02 EN 16146:2012+A1:2014 (E) 5 Introduction In respect of
24、 potential adverse effects on the quality of water intended for human consumption caused by the product covered by this standard, this standard provides no information as to whether the product may be used without restriction in any of the Member States of the EU or EFTA. It should be noted that, wh
25、ile awaiting the adoption of verifiable European criteria, existing national regulations concerning the use and/or the characteristics of this product remain in force. DIN EN 16146:2015-02 EN 16146:2012+A1:2014 (E) 6 1 Scope This European Standard applies to hoses for extractable outlets of any mate
26、rial intended for equipping sanitary tapware for sinks and basins. Such hoses will only be connected downstream of the obturator of the tapware. The tapware will comply with EN 200, EN 817, EN 1111, EN 1286 or EN 1287 (see 1, 2, 3, 5 and 6). Hoses intended to connect sanitary tapware to the water su
27、pplies are not covered by this standard. This European Standard specifies: the dimensional, mechanical and hydraulic characteristics with which the hose for extractable outlets shall comply; the procedures for testing these characteristics. Details of pressures and temperatures are given in Table 1.
28、 ! Table 1 Conditions of use/Classifications Water supply system Operating range of hoses for extractable outlets Flow rates (Q)aLimits Recommended Type 1 see Figure 1Dynamic Pressure 0,05 MPa P 0,5 MPa (0,5 bar P 5 bar) Dynamic Pressure 0,1 MPa to 0,3 MPa (1,0 bar to 3,0 bar) Class 1: Q 0,25 l/s (1
29、5 l/min) Class 2: Q 0,15 l/s (9 l/min) Type 2 see Figure 2Dynamic Pressure 0,01 MPa to 0,2 MPa (0,1 bar to 2,0 bar) Dynamic Pressure 0,02 MPa to 0,10 MPa (0,2 bar to 1,0 bar) Class E: 0,06 l/s Q 0,18 l/s (3,6 l/min Q 10,8 l/min.) Class H: 0,18 l/s Q (10,8 l/min Q) Temperature T 70C T 60C aSee detail
30、s in Table 3. “ DIN EN 16146:2015-02 EN 16146:2012+A1:2014 (E) 7 Key 1 cold water 2 hot water 3 mains supply pipe (Supply pressures up to 1,0 MPa (10 bar) 4 water heater Figure 1 Type 1 Supply system - with a pressure range of 0,05 MPa to 1,0 MPa (0,5 bar to 10 bar) DIN EN 16146:2015-02 EN 16146:201
31、2+A1:2014 (E) 8 Key 1 cold water storage cistern (cover omitted for clarity) 2 warning pipe 3 vent pipe 4 hot water cylinder 5 alternative cistern fed cold supply to sanitary appliances 6 to boiler 7 mains supply pipe (Supply pressures up to 1,0 MPa (10 bar) Figure 2 Type 2-Supply system - with a pr
32、essure range of 0,01 MPa to 1,0 MPa, (0,1 bar to 10 bar): A vented domestic hot water and cold water supply system incorporating gravity hot water, mains cold water and alternative gravity cold water supply to sanitary appliances 2 Normative references The following documents, in whole or in part, a
33、re normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 248, Sanitary tapware General specification for ele
34、ctrodeposited coatings of Ni-Cr EN ISO 228-1, Pipe threads where pressure-tight joints are not made on the threads Part 1: Dimensions, tolerances and designation (ISO 228-1) DIN EN 16146:2015-02 EN 16146:2012+A1:2014 (E) 9 3 Terms and definitions For the purposes of this document, the following term
35、s and definitions apply. 3.1 hose for extractable outlets flexible supply pipe which connects sanitary tapware to an extractable outlet 4 Designation Hoses for extractable outlets complying with this standard, are designated by: type; connecting thread dimensions e.g. G 1/2 G 1/2 or G 1/2 G 3/4; len
36、gth; material of the external sheath (plastic, metal); type of nuts and if conical the dimension C; reference to this standard: EN 16146; flow rate Class (see Table 1). EXAMPLE Hose for extractable outlet type, G 1/2, cone 26 G 3/4, length 1,5m, metal sheath, EN 16146, Class H. 5 Marking Extractable
37、 hoses complying with this standard shall be marked permanently and legibly with the manufacturers mark or the suppliers mark. The flow rate class shall appear on the product but it need not be permanent. Hoses for extractable outlets with special dimensions (see 7.3) delivered together with the tap
38、ware need not be marked individually. 6 Materials 6.1 Chemical and hygienic requirements All materials coming into contact with water intended for human consumption shall present no risk to health. They shall not cause any change of the drinking water in terms of quality, appearance, smell or taste.
39、 6.2 Exposed surface condition and quality of coating Visible chromium plated surfaces and Ni-Cr coatings shall comply with the requirements of EN 248. DIN EN 16146:2015-02 EN 16146:2012+A1:2014 (E) 10 7 Dimensional characteristics 7.1 General General comment on design: the design and construction o
40、f components without defined dimensions permits various design solutions to be adopted by the manufacturer; permitted deviations from the defined dimensions are given in 7.3. 7.2 Connecting dimensions The connecting dimensions of hoses for extractable outlets are specified in Table 2 and Figures 3 t
41、o 5. Table 2 Connecting dimensions Dimensions Values Comments A G 1/2, G 3/8 or 15 1 mm or other EN ISO dimensions Connecting thread (tap side) B G 1/2 Connecting thread (extractable outlet side) EN ISO 228-1 C 23 0501,+mm or 26 0501,+mm Major diameter of conical nut (if provided) G 8,5 0/-1 mm Func
42、tional dimension on seal depth I 1,5 005,+mm Thread counter bore K 30 mm Total length of conical nut 3 0/-1 mm Cone angle (if provided) L 500 mm Total length of hose a) Conical nut b) Nut (shape unspecified) Figure 3 Terminal nuts DIN EN 16146:2015-02 EN 16146:2012+A1:2014 (E) 11 Figure 4 Female or
43、male end (shape unspecified) Figure 5 Hose length 7.3 Special cases Hoses for extractable outlets intended for special applications e.g. when interchangeability is not a requirement, can incorporate the following dimensional deviations: connection to the tapware is guaranteed; threaded connections a
44、re in compliance with ISO standards; all other requirements of this standard are satisfied; the manufacturers literature, including the installation instructions supplied with the hoses for extractable outlets, indicates clearly that the hoses for extractable outlets are special cases. 8 Hydraulic c
45、haracteristics 8.1 General The test described is a type test (laboratory test) and not a quality control test carried out during manufacture. 8.2 Flow rate 8.2.1 Test method This clause describes a method for testing the flow rate of hoses. 8.2.2 Principle The principle consists of a method for meas
46、uring the flow rate through the hoses for extractable outlets using cold water (T 30 C) in order to determine the flow rate class of the hose (see Table 1). The flow rate of hoses for extractable outlets with special connection (see 7.3) delivered together with the tapware is measured in combination
47、 with the complete sanitary tapware. DIN EN 16146:2015-02 EN 16146:2012+A1:2014 (E) 12 8.2.3 Apparatus The test apparatus is shown in Figure 6. 8.2.4 Procedure Connect the G 1/2 size nut of the hose for extractable outlets to the pressure take-off tee, supporting the hose in a horizontal position; a
48、pply the required dynamic pressure using the horizontal axis of the hose as a datum; record the flow rate “Q” (Table 1) after stabilisation. 8.2.5 Requirements Hoses for extractable outlets shall be classified according to the flow rate value “Q” at the required pressure as shown in Table 3. ! Table
49、 3 Flow rate classes Supply system Flow rate / Pressure Type 1 Class 1 Q 0,25 l/s (15 l/min) at (0 02003,+) MPa (0203,+) bar) Class 2 Q 0,15 l/s (9 l/min) at (0 02003,+) MPa (0203,+) bar) Type 2 Class E 0,06 l/s Q 0,18 l/s (3,6 l/min Q 10,8 l/min) at (0 00200 01,+) MPa (0 02001,+) bar) Class H 0,18 l/s Q (10,8 l/min Q) at (0 00200 01,+) MPa (0 02001,+) bar) “ DIN EN 16146:2015-02 EN 16146:2012+A1:2014 (E) 13 Key