1、September 2013 Translation by DIN-Sprachendienst.English price group 13No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).
2、ICS 45.060.20!%)English version EN 16286-2:2013,English translation of DIN EN 16286-2:2013-09Bahnanwendungen bergangssysteme zwischen Fahrzeugen Teil 2: Messung der Akustik;Englische Fassung EN 16286-2:2013,Englische bersetzung von DIN EN 16286-2:2013-09Applications ferroviaires Systmes dintercircul
3、ation entre vhicules Partie 2: Mesures acoustiques;Version anglaise EN 16286-2:2013,Traduction anglaise de DIN EN 16286-2:2013-09SupersedesDIN EN 16286-2:2013-06www.beuth.deDocument comprises 27 pagesIn case of doubt, the German-language original shall be considered authoritative.08.13DIN EN 16286-2
4、:2013-09 2 A comma is used as the decimal marker. National foreword This document (EN 16286-2:2013) has been prepared by Technical Committee CEN/TC 256 “Railway applications” (Secretariat: DIN, Germany). The responsible German body involved in its preparation was the Normenausschuss Fahrweg und Schi
5、enenfahrzeuge (Railway Standards Committee), Working Committee NA 087-00-11-01 UA bergnge. This standard is based on the English reference version. Amendments Compared with DIN EN 16286-2:2013-06, the following corrections have been made to the German version only and therefore do not affect the Eng
6、lish text: a) Subclause 3.13, Note 3 to entry: “Siehe Bild 3 bis 5.” has been replaced by “Siehe Bild 3 bis Bild 5.” (See Figure 3 to Figure 5.); b) Subclause 3.18, Equation (14): “=c101mcInInc101log10LSSL” has been replaced by “=c101mcInInc101log10LmSSL”; c) Key to Figure 7: “3 Massivwand” has been
7、 replaced by “3 doppelte Abschlussplatte” (3 double panel) and “4 doppelte Abschlussplatte” has been replaced by: “4 Massivwand” (4 solid wall); d) Subclause 6.2, 7th paragraph: “Fr den Fall eines freistehenden bergangs sollten die abgedeckten ffnungen einen Mindestabstand von 1 m zu jeder Wand aufw
8、eisen.” has been replaced by “Fr den Fall eines freistehenden bergangs sollten die abgedeckten ffnungen einen Mindestabstand von 1,0 m zu jeder Wand aufweisen.” (In the case of a free standing gangway the covered openings should have a minimum distance of 1,0 m to any wall.); e) Subclause 6.4.7, def
9、inition of Sm: “Smder gemessene Gesamtbereich und durch Siangegeben.” has been replaced by “Smder gemessene Gesamtbereich und durch Smiangegeben.” (is the total area measured and is given by Smi); f) Clause 7, 1st sentence: “Fr die Angabe der Luftschalldmmung des Prfkrpers muss das Schalldmmma bei a
10、llen Messfrequenzen auf eine Dezimalstelle in Tabellenformat und in Form einer Kurve, zusammen mit dem Schallfeld-Druckindikator, angegeben werden.” has been replaced by “Fr die Angabe der Luftschalldmmung des Prfkrpers muss das Schalldmmma RI bei allen Messfrequenzen auf eine Dezimalstelle in Tabel
11、lenformat und in Form einer Kurve, zusammen mit dem Schallfeld-Druckindikator, angegeben werden.” (For the statement of the airborne sound insulation of the test specimen, the intensity sound reduction index RI shall be given at all frequencies of measurement to one decimal place in a tabular form a
12、nd in the form of a curve, together with the sound field pressure-intensity indicator). Previous editions DIN EN 16286-2: 2013-06 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16286-2 March 2013 ICS 45.060.20 English Version Railway applications - Gangway systems between vehicles - Part 2: Ac
13、oustic measurements Applications ferroviaires - Systmes dintercirculation entre vhicules - Partie 2: Mesures acoustiques Bahnanwendungen - bergangssysteme zwischen Fahrzeugen - Teil 2: Messung der Akustik This European Standard was approved by CEN on 16 February 2013. CEN members are bound to comply
14、 with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC M
15、anagement Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same
16、 status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg,
17、Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2013 CEN All rig
18、hts of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16286-2:2013: EEN 16286-2:2013 (E) 2 Contents Page Foreword 3 Introduction .4 1 Scope 5 2 Normative references 5 3 Terms and definitions .6 4 Instrumentation and calibration 13 4.1 Instrumentati
19、on . 13 4.2 Calibration . 13 5 Measurement setup 13 6 Test procedure 16 6.1 General . 16 6.2 Generation of sound field 16 6.3 Sound pressure level in the source room 17 6.4 Measurement of average sound intensity level on the measurement surface 17 6.4.1 General . 17 6.4.2 Measurement surface . 18 6.
20、4.3 Qualification of the measurement surface . 18 6.4.4 Scanning procedure . 19 6.4.5 Procedure using discrete positions 19 6.4.6 Scanning procedure for one measurement area . 19 6.4.7 Scanning procedure for several measurement subareas 20 6.5 Background noise. 20 6.6 Frequency range of measurements
21、 20 7 Presentation of results . 20 8 Quality of the measurements 21 8.1 Deviations from the requirements 21 8.2 Measurement tolerances 21 8.3 Measurement uncertainties . 21 9 Test report . 21 Annex A (normative) Method to qualify the sound field on the surface of the test specimen in the source room
22、 23 Bibliography . 25 DIN EN 16286-2:2013-09 EN 16286-2:2013 (E) 3 Foreword This document (EN 16286-2:2013) has been prepared by Technical Committee CEN/TC 256 “Railway Applications”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, ei
23、ther by publication of an identical text or by endorsement, at the latest by September 2013, and conflicting national standards shall be withdrawn at the latest by September 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CE
24、N and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. This series of European Standards EN 16286, Railway applications Gangway syst
25、ems between vehicles, consists of the following parts: Part 1: Main applications Part 2: Acoustic measurements According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria,
26、 Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey
27、and the United Kingdom. DIN EN 16286-2:2013-09 EN 16286-2:2013 (E) 4 Introduction This European Standard presents a measurement method to collect information about the noise insulation of rail bound vehicle gangway systems. These components need their own measurement procedure as the geometrical sou
28、nd distribution situation is not in line with the basic assumptions of general standards about noise insulation measurements as provided for building elements, etc. In this standard, a number of different setups are described, which represent possible approaches to the ideal test situation. As the a
29、pproaches may contradict the ideal sound fields, the standard includes methods to assess the influence of reflections and other difficulties in order to reduce the uncertainties of these test methods to an acceptable amount in Annex A. DIN EN 16286-2:2013-09 EN 16286-2:2013 (E) 5 1 Scope This Europe
30、an Standard specifies a measurement method and conditions to obtain reproducible and comparable sound reduction indices of all kinds of rail bound vehicles gangway systems defined in EN 16286-1. The setup should include all components of the system mounted like this is done between two adjacent car
31、bodies within the train, so that a person will be able to use the gangway system, consisting of e.g: the bridge system (footplate); side panels; flexible components (bellows); mounting systems; elements to couple parts in case of separable gangway systems. If separable gangway systems shall be measu
32、red, the whole system between two adjacent car bodies should be used. The method is applicable to type testing of gangways. This method is not applicable to: interior noise measurements in vehicles; structure borne noise measurements. The type testing procedures specified in this European Standard a
33、re of engineering grade (grade 2) in the frequency range from 100 Hz up to 5 kHz; that is the preferred range for noise declaration purposes, as defined in EN ISO 12001. If test conditions are relaxed, the results are no longer of engineering grade. 2 Normative references The following documents, in
34、 whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ENV 13005, Guide to the expression
35、 of uncertainty in measurement EN 60942, Electroacoustics Sound calibrators (IEC 60942) EN 61672-1, Electroacoustics Sound level meters Part 1: Specifications (IEC 61672-1) EN 61672-2, Electroacoustics Sound level meters Part 2: Pattern evaluation tests (IEC 61672-2) EN ISO 266, Acoustics Preferred
36、frequencies (ISO 266) EN ISO 3741, Acoustics Determination of sound power levels and sound energy levels of noise sources using sound pressure Precision methods for reverberation test rooms (ISO 3741) EN ISO 9614-1:2009, Acoustics Determination of sound power levels of noise sources using sound inte
37、nsity Part 1: Measurement at discrete points (ISO 9614-1:1993) EN ISO 10140-2, Acoustics Laboratory measurement of sound insulation of building elements Part 2: Measurement of airborne sound insulation (ISO 10140-2) DIN EN 16286-2:2013-09 EN 16286-2:2013 (E) 6 EN ISO 10140-4:2010, Acoustics Laborato
38、ry measurement of sound insulation of building elements Part 4: Measurement procedures and requirements (ISO 10140-4:2010) EN ISO 10140-5, Acoustics Laboratory measurement of sound insulation of building elements Part 5: Requirements for test facilities and equipment (ISO 10140-5) EN ISO 15186-1, Ac
39、oustics Measurement of sound insulation in buildings and of building elements using sound intensity Part 1: Laboratory measurements (ISO 15186-1) 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 sound pressure p root mean square (RMS) value of
40、 a fluctuating pressure superimposed on the static atmospheric pressure measured over a certain time period, expressed in Pa 3.2 sound pressure level Lplevel given by the formula: 2log )( 10 0pp/pL = dB (1) where Lpis the sound pressure level in dB; p is the RMS sound pressure in Pa; p0the reference
41、 sound pressure; p0= 20 Pa Note 1 to entry Adapted from ISO 1996-1. 3.3 average sound pressure level in a source room Lp1ten times the logarithm to the base 10 of the ratio of the space and time average of the sound pressure squared to the square of the reference sound pressure, the space average be
42、ing taken over the entire room with the exception of those parts where the direct radiation of a sound source or the near field of the boundaries (wall, window, etc.) is of significant influence Note 1 to entry This quantity is given in decibels. Note 2 to entry For a complete definition, see EN ISO
43、 10140-2. 3.4 sound reduction index R ten times the logarithm to the base 10 of the ratio of the sound power W1incident on the test specimen to the sound power W2transmitted through the specimen: dBlog1021=WWR(2) DIN EN 16286-2:2013-09 EN 16286-2:2013 (E) 7 Note 1 to entry The expression “sound tran
44、smission loss“ is also in use. 3.5 sound intensity I time-averaged rate of flow of sound energy per unit area oriented normal to the local particle velocity; this is a vectorial quantity which is equal to: ( ) ( )01dTI pt ut tT=(3) where p(t) is the instantaneous sound pressure at a point, in Pascal
45、s; ( )tuis the instantaneous particle velocity at the same point, in meters per second; T is the averaging time, in seconds Note 1 to entry Sound intensity is measured in watts per square meter. 3.6 normal sound intensity Incomponent of the sound intensity in the direction normal to a measurement su
46、rface defined by the unit normal vector n: nI In=(4) where nis the unit normal vector directed out of the volume enclosed by the measurement surface 3.7 normal sound intensity level LInten times the logarithm to the base 10 of the ratio of the unsigned value of the normal sound intensity to the refe
47、rence intensity I0, as given by: 0nInlog10IIL = dB (5) where 12010=I W/m2(6) 3.8 surface pressure-intensity indicator FpIdifference between the sound pressure level, Lp, and the normal sound intensity level, LIn, on the measurement surface, both being time and surface averaged: InppILLF = (7) DIN EN
48、 16286-2:2013-09 EN 16286-2:2013 (E) 8 Note 1 to entry This notation is in accordance with EN ISO 9614-2. In EN ISO 9614-1, the notation F2 is used. 3.9 pressure-residual intensity index pI0 difference between the indicated sound pressure level, Lp, and the indicated sound intensity level, LI, when
49、the intensity probe is placed and oriented in a sound field such that the sound intensity is zero Note 1 to entry pI0 is expressed in decibels. Note 2 to entry Details for determining pI0 are given in EN 61043: ( )IppI0LL = 3.10 intensity sound reduction index of a gangway RIGindex evaluated from Formula (2), assuming that the sound field in the source room is diffuse: +=SSLLLRmIncp1IGlog106 (in dB) (8) where Lp1is