1、April 2017 English price group 11No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 91.100.60!%c2“2649915www.din.deDIN
2、 EN 16809-2Thermal insulation products of buildings Insitu formed products from loosefill expanded polystyrene (EPS) beads and bonded expanded polystyrene beads Part 2: Specification for the bonded and loosefill products after installation;English version EN 168092:2017,English translation of DIN EN
3、 16809-2:2017-04Wrmedmmstoffe fr Gebude An der Verwendungsstelle hergestellte Produkte aus losen expandierten Polystyrolkugeln (EPS) und gebundenen expandierten Polystyrolkugeln Teil 2: Spezifikation fr gebundene und lose Schtt und Einblasdmmstoffe nach dem Einbau;Englische Fassung EN 168092:2017,En
4、glische bersetzung von DIN EN 16809-2:2017-04Produits isolants thermiques destins aux btiments Produits forms sur place partir de billes en polystyrne expans (EPS) en vrac et de billes en polystyrne expans lies Partie 2: Spcification pour les produits lis et en vrac aprs mise en oeuvre;Version angla
5、ise EN 168092:2017,Traduction anglaise de DIN EN 16809-2:2017-04www.beuth.deDTranslation by DIN-Sprachendienst.In case of doubt, the German-language original shall be considered authoritative.Document comprises 17 pages 03.17 2 A comma is used as the decimal marker. National foreword This document (
6、EN 16809-2:2017) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products” (Secretariat: DIN, Germany). The responsible German body involved in its preparation was DIN-Normenausschuss Bauwesen (DIN Standards Committee Building and Civil Engineering), Working Comm
7、ittee NA 005-56-60 AA “Thermal insulation materials (national mirror committee for CEN/TC 88 and WG 1 to 9, WG 12 to 21, ISO/TC 61/SC 10, ISO/TC 163 (partly), ISO/TC 163/SC 1 and SC 3)”. DIN EN 16809-2:2017-04EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16809-2 January 2017 ICS 91.100.60 Eng
8、lish Version Thermal insulation products of buildings - In-situ formed products from loose-fill expanded polystyrene (EPS) beads and bonded expanded polystyrene beads - Part 2: Specification for the bonded and loose-fill products after installation Produits isolants thermiques destins aux btiments -
9、 Produits forms sur place partir de billes en polystyrne expans (PSE) en vrac et de billes en polystyrne expans lies - Partie 2: Spcification pour les produits lis et en vrac aprs mise en uvre Wrmedmmstoffe fr Gebude - An der Verwendungsstelle hergestellte Produkte aus losen expandierten Polystyrolk
10、ugeln (EPS) und gebundenen expandierten Polystyrolkugeln - Teil 2: Spezifikation fr gebundene und lose Schtt- und Einblasdmmstoffe nach dem Einbau This European Standard was approved by CEN on 23 October 2016. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate
11、the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standa
12、rd exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the natio
13、nal standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serb
14、ia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by
15、any means reserved worldwide for CEN national Members. Ref. No. EN 16809-2:2017 EEN 16809-2:2017 (E) 2 Contents Page European foreword . 4 1 Scope 5 2 Normative references 5 3 Terms, definitions, symbols and abbreviations . 5 3.1 Terms and definitions . 5 3.2 Symbols and abbreviations . 6 4 Requirem
16、ents . 6 4.1 General 6 4.2 Suitability of the building for the installation of the product . 6 4.3 In situ measurements and calculations . 6 4.3.1 General 6 4.3.2 The installed thermal resistance of masonry cavity wall and frame construction insulation . 7 5 Installation checks 7 5.1 Average cavity
17、width 7 5.2 Machine output 7 5.3 Installed volume 7 5.4 Thermal resistance of installed masonry cavity wall and frame construction installation . 7 6 Guidelines for installation . 8 7 Installer s declaration . 8 Annex A (normative) Masonry cavity walls Determination of average cavity width . 9 A.1 P
18、rocedure. 9 A.2 Calculation . 9 Annex B (normative) Masonry cavity walls and frame constructions Flow check procedures 10 B.1 Apparatus 10 B.2 Procedure 10 Annex C (normative) Masonry cavity walls Use of endoscope to check adequacy of fill 11 C.1 Selection of inspection positions by the inspector. 1
19、1 C.2 Action to be taken by the inspector . 11 Annex D (normative) Guidance for the installer Suitability of the building, training, pre-checks and installation declaration 12 D.1 Masonry cavity walls . 12 D.1.1 Suitability of the building to receive the insulation 12 D.1.2 Suitability of the buildi
20、ng to receive the insulation 12 D.1.3 Installation procedure . 13 DIN EN 16809-2:2017-04 EN 16809-2:2017 (E) 3 D.2 Frame constructions (new build walls) 13 D.2.1 Suitability of the building to receive the insulation . 13 D.2.2 Control tests made by the installer when preparing the product on site 14
21、 D.2.3 Installation procedure 14 D.2.4 An example of a declaration form for use by the installer . 14 Bibliography . 15 DIN EN 16809-2:2017-04 EN 16809-2:2017 (E) 4 European foreword This document (EN 16809-2:2017) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating products and m
22、aterials”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2017, and conflicting national standards shall be withdrawn at the latest by July 2017. Att
23、ention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights. Thermal insulation products of buildings In situ formed products from loose-fill expanded polystyrene (E
24、PS) beads and bonded expanded polystyrene beads, consists of the following parts: Part 1: Specification for the bonded and loose filled products before installation Part 2: Specification for the bonded and loose-fill products after installation (the present document). This document has been prepared
25、 under a mandate given to CEN by the European Commission and the European Free Trade Association. According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyp
26、rus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and t
27、he United Kingdom. DIN EN 16809-2:2017-04 EN 16809-2:2017 (E) 5 1 Scope This European Standard specifies the requirements for products of loose-fill expanded polystyrene (EPS) beads and bonded expanded polystyrene beads installed in masonry cavity walls and frame constructions. This European Standar
28、d is a specification for the installed insulation products. This European Standard describes, when taken together with EN 16809-1, the product characteristics that are linked to the essential requirements of the Regulation (EU) 305/2011. It also specifies the checks and tests to be used for the decl
29、arations made by the installer of the product and the rules for the evaluation of conformity. This European Standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given app
30、lication are to be found in regulations or non-conflicting standards. For example, see the note in the scope of EN 16809-1 regarding the possibility of special water penetration tests in different Member States. Products with a declared thermal conductivity at 10 C greater than 0,060 W/(mK) are not
31、covered by this standard. This European Standard does not cover factory made expanded polystyrene products in the form of mats, batts, rolls or boards. This European Standard does not cover products intended for airborne sound insulation and for acoustic absorption applications. 2 Normative referenc
32、es The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 1
33、6809-1, Thermal insulation products for buildings In-situ formed loose-fill expanded polystyrene (EPS) products Part 1: Specification for the loose-fill products before installation 3 Terms, definitions, symbols and abbreviations 3.1 Terms and definitions For the purposes of this document, the follo
34、wing terms and definitions apply. 3.1.1 expanded polystyrene beads insulation material consisting of beads manufactured from expandable polystyrene or one of its copolymers with an air filled closed cellular structure 3.1.2 installed declared insulation thickness insulation thickness as installed by
35、 the installer 3.1.3 frame construction walls with wood or metal studs, sloping roof with insulation between rafters DIN EN 16809-2:2017-04 EN 16809-2:2017 (E) 6 3.1.4 performance chart table giving thickness and coverage requirements for different values of declared thermal resistance 3.1.5 system
36、particular type of loose fill expanded polystyrene insulation used in conjunction with a defined blowing machine with a blowing hose and defined nozzle and bonding adhesive when used 3.1.6 blowing hole hole, cut or formed, in a masonry cavity wall or frame construction, through which the expanded po
37、lystyrene is blown 3.2 Symbols and abbreviations For the purposes of this document, the following terms and definitions apply. d is the installed declared insulation thickness mm iis one test result of thermal conductivity W/(mK) Dis the declared thermal conductivity W/(mK) R is the thermal resistan
38、ce m2K/W RDis the installed declared thermal resistance m2K/W Wp is the short-term water absorption kg/m2For the purposes of this document, the following abbreviation applies. EPS Expanded PolyStyrene 4 Requirements 4.1 General The installer shall use an insulation product that complies with EN 1680
39、9-1 in a system appropriate to the application. 4.2 Suitability of the building for the installation of the product The installer shall inspect the building in accordance with manufacturers guidelines and national regulations, in order to determine whether it is suitable for application of the produ
40、ct. Typical checklist is given in Annex D. 4.3 In situ measurements and calculations 4.3.1 General Properties of the installed product shall be assessed in accordance with Clause 5. To comply with this standard, products shall meet the requirements of 4.3.2. One test result on a product property is
41、the average of the measured values. The calculated thermal resistance level is for the insulation only, disregarding the effects of studs, beams, rafters, etc. DIN EN 16809-2:2017-04 EN 16809-2:2017 (E) 7 NOTE 1 EN ISO 10456 describes how the design thermal conductivity is calculated from the declar
42、ed thermal conductivity. NOTE 2 For calculating the thermal resistance of complete building elements involving the use of these products the procedures given in EN ISO 6946 can be used. 4.3.2 The installed thermal resistance of masonry cavity wall and frame construction insulation Thermal resistance
43、 shall be assessed by means of the procedure given in 5.4. The installed thermal resistance can also be calculated using the formula: ( )1/DRd = (1) where R is the installed thermal resistance (m2K/W); d is the cavity/frame width (m); Dis the declared thermal conductivity (W/(mK). The value of the t
44、hermal resistance level shall be rounded downward to the nearest 0,05 m2K/W and declared in steps of 0,05 m2K/W. 5 Installation checks 5.1 Average cavity width The minimum width and the average width of the cavity shall be established through a minimum of holes in accordance with Annex A. The minimu
45、m cavity width shall not be less than specified by the system designer. The area to be filled with insulation shall be calculated from the square meters of the property less the windows, doors and any obstructions. 5.2 Machine output The blowing machine shall be set in accordance with the insulation
46、 product manufacturers instructions. The machine output shall be adjusted to control the flow rates of beads and (where applicable) adhesive as specified by the manufacturer in accordance with Annex B. 5.3 Installed volume The installed volume shall be monitored from the supply vehicle and volume in
47、stalled shall match the volume calculated i.e. the average cavity width multiplied by the area to be filled. In case of dispute the adequacy of fill can be determined using an endoscope in accordance with Annex C. 5.4 Thermal resistance of installed masonry cavity wall and frame construction install
48、ation The thermal resistance shall be assessed by measurement of: a) average cavity width according to 5.1; b) machine output according to 5.2; c) installed volume according to 5.3. DIN EN 16809-2:2017-04 EN 16809-2:2017 (E) 8 6 Guidelines for installation National Practice or Local Rules and Manufa
49、cturers instructions shall be followed. 7 Installer s declaration The installer shall declare to the customer that the work has been carried out in accordance with the requirements of this standard using an insulation product that complies with EN 16809-1. The installer shall also state at least the following information: a) trade name and designation code for the installed product; b) number of EC certificat