1、April 2013 Translation by DIN-Sprachendienst.English price group 9No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 5
2、9.080.60; 97.150!$Q“1999346www.din.deDDIN EN ISO 24342Resilient and textile floor-coverings Determination of side length, edge straightness and squareness of tiles(ISO 24342:2007 + Amd.1:2012);English version EN ISO 24342:2012 + A1:2012,English translation of DIN EN ISO 24342:2013-04Elastische und t
3、extile Bodenbelge Bestimmung der Kantenlnge, Rechtwinkligkeit und Geradheit von Platten(ISO 24342:2007 + Amd.1:2012);Englische Fassung EN ISO 24342:2012 + A1:2012,Englische bersetzung von DIN EN ISO 24342:2013-04Revtements de sol rsilients ou textiles Dtermination de la longueur des bords, de la rec
4、titude des artes et de lquerrage desdalles (ISO 24342:2007 + Amd.1:2012);Version anglaise EN ISO 24342:2012 + A1:2012,Traduction anglaise de DIN EN ISO 24342:2013-04SupersedesDIN EN ISO 24342:2012-04www.beuth.deDocument comprises pagesIn case of doubt, the German-language original shall be considere
5、d authoritative.1503.13DIN EN ISO 24342:2013-04 2 A comma is used as the decimal marker. National foreword The text of ISO 24342:2007 including Amendment 1:2012 has been prepared by Technical Committee ISO/TC 219 “Floor coverings” (Secretariat: KATS, Republic of Korea) and has been taken over as EN
6、ISO 24342:2012 + A1:2012 by Technical Committee CEN/TC 134 “Resilient, textile and laminate floor coverings” (Secretariat: NBN, Belgium). The responsible German body involved in its preparation was the Normenausschuss Kunststoffe (Plastics Standards Committee), Joint Working Committee NA 054-04-08 G
7、A Gemeinschaftsausschuss FNK/NHM: Spiegelausschuss zu CEN/TC 134 und ISO/TC 219. This standard includes Amendment A1 approved by CEN on 30 November 2012. The start and finish of text introduced or altered by amendment is indicated in the text by tags . Amendments This standard differs from DIN EN IS
8、O 24342:2012-04 as follows: a) Clause 6 “Atmosphere for conditioning and testing” has been subdivided into Subclauses 6.1 “Resilient floor coverings” and 6.2 “Textile floor coverings”. Previous editions DIN EN 427: 1994-11 DIN EN ISO 24342: 2012-04 !“EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM
9、 EN ISO 24342 January 2012 + A1 December 2012 ICS 97.150 Supersedes EN ISO 24342:2012English Version Resilient and textile floor-coverings - Determination of side length, edge straightness and squareness of tiles (ISO 24342:2007 + Amd 1:2012) Revtements de sol rsilients ou textiles - Dtermination de
10、 la longueur des bords, de la rectitude des artes et de lquerrage des dalles (ISO 24342:2007 + Amd 1:2012) Elastische und textile Bodenbelge - Bestimmung der Kantenlnge, Rechtwinkligkeit und Geradheit von Platten (ISO 24342:2007 + Amd 1:2012) EN ISO 24342:2004 was approved by CEN on 2011-12-17 and A
11、mendment A1:2012 on 2012-11-30. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationa
12、l standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language
13、 and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hu
14、ngary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Manage
15、ment Centre: Avenue Marnix 17, B-1000 Brussels 2012 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN ISO 24342:2012 + A1:2012 EContents Page Foreword to EN ISO 24342:2007 3 !Foreword to EN ISO 24342:2012/A1:2012“ 3 1 Scope 4 2 Terms
16、 and definitions .4 3 Principle 5 4 Apparatus .5 5 Sampling and selection of specimens 9 6 Atmosphere for conditioning and testing .9 6.1 !Resilient floor coverings“ 10 6.2 !Textile floor coverings“ 10 7 Procedure .10 7.1 General 10 7.2 Side length 10 7.2.1 Gauge method 10 7.2.2 Movable dial gauge m
17、ethod 10 7.2.3 Sliding calliper method .10 7.3 Squareness .11 7.3.1 Thickness gauge method 11 7.3.2 Movable dial gauge method 11 7.4 Straightness .11 7.4.1 Thickness gauge method 11 7.4.2 Movable dial gauge method 11 8 Calculation and expression of the results 11 8.1 For thickness gauge apparatus 11
18、 8.1.1 Side length 11 8.1.2 Squareness .11 8.1.3 Straightness .11 8.2 For movable dial gauge apparatus 11 8.3 For the sliding calliper apparatus 11 9 Precision statement .11 10 Test report 12 Bibliography 13 2 DIN EN ISO 24342:2013-04 EN ISO 24342:2012 + A1:2012 (E) Foreword to EN ISO 24342:2007 The
19、 text of ISO 24342:2007 has been prepared by Technical Committee ISO /TC 219 “Floor coverings” of the International Organization for Standardization (ISO) and has been taken over as EN ISO 24342:2012 by Technical Committee CEN/TC 134 “Resilient, textile and laminate floor coverings” the secretariat
20、of which is held by BSI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by July 2012, and conflicting national standards shall be withdrawn at the latest by July 2012. Attention is drawn to the poss
21、ibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 427:1994. According to the CEN/CENELEC Internal Regulations, the national standards orga
22、nizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Po
23、rtugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Endorsement notice The text of ISO 24342:2007 has been approved by CEN as EN ISO 24342:2012 without any modification. !Foreword to EN ISO 24342:2012/A1:2012 coverings” the secretariat of which is held by
24、NBN. This Amendment to the European Standard EN ISO 24342:2012 shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2013, and conflicting national standards shall be withdrawn at the latest by June 2013. Attention is dr
25、awn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the follow
26、ing countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, No
27、rway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. Endorsement notice The text of ISO 24342:2007/Amd 1:2012 has been approved by CEN as EN ISO 24342:2012/A1:2012 without any modification.“ 3 DIN EN ISO 24342:2013-04 EN ISO 24342:2012 + A1:
28、2012 (E) This document (EN ISO 24342:2012/A1:2012) has been prepared by Technical Committee ISO/TC 219 “Floor coverings” in collaboration with Technical Committee CEN/TC 134 “Resilient, textile and laminate floor 1 Scope This International Standard describes methods for determining side lengths, str
29、aightness of edges and squareness of resilient or textile floor tiles. The side lengths, straightness and squareness of resilient or textile floor tiles are important considerations because installed flooring will have an objectionable appearance if these performance criteria are not followed. This
30、may cause the installed tiles to line up unevenly, producing unsightly seams and corners that do not match. 2 Terms and definitions For the purposes of this document, the following terms and definitions apply. 2.1 squareness measurement of the amount each corner of the tile deviates from 90 See Figu
31、re 1. Figure 1 Definition of squareness 2.2 straightness property of an edge to be straight, unbent See Figure 2. 4 DIN EN ISO 24342:2013-04 EN ISO 24342:2012 + A1:2012 (E) Figure 2 Definition of straightness 2.3 tile type of resilient or textile flooring of predetermined shape intended to be used i
32、n a modular mode NOTE Tiles are usually square, but can also be rectangular, e.g. “plank”, “panel”. 3 Principle The surface dimensions of a tile are measured by a contact method at defined positions in each direction. To assess the squareness, each corner of a right-angled tile is fitted into the di
33、hedral angle of a precision square and the maximum gap between the arm of the square and the ends of the tile is measured. The maximum opening between the arm and the edge is measured at defined points along the edge to assess the straightness. 4 Apparatus 4.1 Reference plate (calibration plate), ma
34、de to the target dimensions of the manufactured tile. The length and width dimensions shall be within 0,02 mm of the specified dimensions of the resilient or textile tiles. The reference plate shall contain at least two sides that are perpendicular to 0,000 05 rad (0,003) to one or another and are u
35、sed to set squareness gauge to zero (see Figure 3). 5 DIN EN ISO 24342:2013-04 EN ISO 24342:2012 + A1:2012 (E) Dimensions in millimetres aTile target dimension 0,02 mm. b1,570 80 rad 0,000 05 rad. Figure 3 Reference plate 4.2 Rigid metal or glass plate, squared and finished, with dimensions 5 mm to
36、10 mm less than those of the tile, for the thickness gauge method. The mass per unit area of the plate shall be approximately 20 kg/m2. 4.3 Flat bedplate apparatus, for measuring squareness and straightness of floor tiles. This apparatus shall be an “L” shaped steel device having an angle of 1,570 8
37、0 rad (90) with a tolerance of 0,000 05 rad (0,003), as shown in Figures 4 and 5 with the length of both reference strips larger than the largest dimension of the tile. For measuring side length, a dial gauge is also placed on the flat bedplate according to Figure 6. 6 DIN EN ISO 24342:2013-04 EN IS
38、O 24342:2012 + A1:2012 (E) Key 1 measuring tool 2 tile aMaximum length of gap. Figure 4 Apparatus and position of tile for measuring straightness Key 1 measuring tool 2 tile aOut-of-squareness. Figure 5 Apparatus and position of tile for measuring squareness 7 DIN EN ISO 24342:2013-04 EN ISO 24342:2
39、012 + A1:2012 (E) Figure 6 Apparatus for measuring side length 4.4 Gauge and/or calliper, for the measurement of the length of the tiles up to 610 mm. A dial gauge, a sliding calliper gauge or equivalent device with an accuracy of 0,05 mm or a set of thickness gauges in steps of 0,05 mm that can be
40、easily inserted at any point between the “L” shaped steel device and the edge of the tile. 4.5 Movable dial gauges apparatus, containing two fixed index strips according to Figure 7. A horizontal index strip shall be mounted parallel to and just inside the lower edge of the bedplate. It shall be 38
41、mm 3 mm greater in length and a minimum of twice the thickness of the largest resilient or textile tile to be tested. A second index strip shall be mounted 1,570 80 0,000 05 rad (90 0,003) to the horizontal index strip. The lower end of this index strip shall be 3,1 mm 0,25 mm above the right end of
42、 the horizontal index strip and is used to locate one corner of the sample tile. The length of the second index strip shall be maximum 10 mm. The four dial gauges are mounted allowing for measurement of various tiles side lengths while remaining within 10 % of the corner of the tile edge (for the tw
43、o corner gauges and one squareness gauge) or within the central 10 % of the tile edge (for the centre gauge only). Dial gauges may report measurements using electrical or mechanical means, but they shall be graduated to read 0,02 mm and have a stem travel greater than 6 mm. The contact foot of the d
44、ial gauge stem shall be flat, 12,7 mm to 19,1 mm in diameter and exert a total force of not more than 1,0 N. Dial gauges shall be securely positioned so that when the reference plate is in place, the contact foot is extended approximately 50 % of its full travel. 8 DIN EN ISO 24342:2013-04 EN ISO 24
45、342:2012 + A1:2012 (E) Dimensions in millimetres Key 1 edge 1 2 edge 2 3 edge 3 4 edge 4 5 horizontal index strip 6 second index strip A,B,C,D dial gauges aTemplate 610 mm 610 mm. bTemplate 508 mm 508 mm. cTemplate 305 mm 305 mm. dTemplate 229 mm 229 mm. Figure 7 Apparatus for measuring side length,
46、 straightness and squareness 5 Sampling and selection of specimens Five tiles shall be taken from the product. Where a pack of tiles comprises the sample, ensure that the first and the last tiles are not selected for testing. Mark the machine direction (MD) on every tile. If the machine direction ca
47、nnot be determined by the appearance of the material, mark one direction. Report that the machine direction could not be determined. 6 Atmosphere for conditioning and testing !Deleted text“ 9 DIN EN ISO 24342:2013-04 EN ISO 24342:2012 + A1:2012 (E) 6.1 !Resilient floor coverings“ !Condition the test
48、 specimen at (23 2) C and (50 5) % relative humidity for at least 24 h and test in the same conditions. Specimens shall be conditioned on a flat surface such as a table or floor surface to ensure they will contact the bedplate uniformly during measurement.“ 6.2 !Textile floor coverings“ !Condition t
49、he test specimen at (20 2) C and (65 4) % relative humidity for at least 24 h and test in the same conditions. Specimens shall be conditioned on a flat surface such as a table or floor surface to ensure they will contact the bedplate uniformly during measurement.“ 7 Procedure 7.1 General Dirt and foreign particles may collect along the upper face of the index strip and affect the zero set point. Use a small brush to maintain the cleanliness of the index strip surfaces before and after each use. In th