1、February 2015Translation by DIN-Sprachendienst.English price group 17No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).IC
2、S 13.040.20!%?r“2285679www.din.deDDIN ISO 16000-29Indoor air Part 29: Test methods for VOC detectors (ISO 16000-29:2014),English translation of DIN ISO 16000-29:2015-02Innenraumluftverunreinigungen Teil 29: Prfverfahren fr VOC-Detektoren (ISO 16000-29:2014),Englische bersetzung von DIN ISO 16000-29:
3、2015-02Air intrieur Partie 29: Mthodes dessai pour dtecteurs de composs organiques volatils (COV)(ISO 16000-29:2014),Traduction anglaise de DIN ISO 16000-29:2015-02www.beuth.deIn case of doubt, the German-language original shall be considered authoritative.Document comprises 44 pages01.15Thisstandar
4、d has been includedin the VDI/DIN Handbookonair quality, Volume 5.A comma is used as the decimal marker. Contents Page National foreword .3 National Annex NA (informative) Bibliography .6 Introduction .9 1 Scope 10 2 Normative references 10 3 Terms and definitions . 10 4 Principle 12 5 Test 12 5.1 R
5、equirements for tests 12 5.2 Test equipment 13 5.3 Conditions for standard response test . 13 5.4 Test methods 14 6 Test report 18 Annex A (informative) Overview of performance requirements . 20 Annex B (informative) Test equipment 21 Annex C (normative) Selection of test gas . 23 Annex D (informati
6、ve) Diffusion tube method 36 Bibliography . 44 DIN ISO 16000-29:2015-022National foreword International technical regulation pertaining to indoor air This standard has been prepared by Technical Committee ISO/TC 146 “Air quality”, Subcommittee SC 6 “Indoor air”, Working Group WG 16 “Test methods for
7、 VOC detectors” (Convenership and Secretariat: DIN, Germany). The responsible German body involved in its preparation was the Kommission Reinhaltung der Luft (KRdL) im VDI und DIN Normenausschuss (Commission on Air Pollution Prevention of VDI and DIN Standards Committee), Section IV Umweltmesstechni
8、k. In addition to the legal units of measurement, this standard also uses the units “ppm” and “ppb”. It should, however, be noted that the Gesetz ber Einheiten im Messwesen (German Law on units in metrology) prohibits the use of these units for official and commercial purposes in Germany. The indica
9、tion of this unit solely serves to facilitate the communication with those countries where this unit is used (import-export business). Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. DIN shall not be held responsible for identifyi
10、ng any or all such patent rights. General and substance-specific aspects which should be taken into account before or during measurements, as well as methods for determining individual substances or substance groups, and microorganisms in indoor air are described in the various parts of ISO 16000. T
11、he DIN Standards corresponding to the International Standards referred to in Clause 2 of this standard are as follows: IEC 61000-4-1 DIN EN 61000-4-1, VDE 0847-4-1 IEC 61000-4-3 DIN EN 61000-4-3, VDE 0847-4-3 IEC 61000-4-4 DIN EN 61000-4-4, VDE 0847-4-4 National technical regulation pertaining to in
12、door air General conditions and other aspects to be taken into consideration when planning indoor air measurements are described for individual substances and substance groups in the VDI 4300 series (see also “National Annex NA”). Many of these served as the sole basis for parts of the ISO 16000 ser
13、ies (e.g. ISO 16000-1, ISO 16000-2, ISO 16000-5, ISO 16000-7, ISO 16000-12, ISO 16000-15, ISO 16000-16, ISO 16000-17, ISO 16000-18 and ISO 16000-26). The specific procedures (sampling, analysis) are described in the VDI 4301 series for individual substances and substance groups. Methods which can be
14、 used for both indoor and ambient air measurements are described in further VDI Guidelines. The DIN ISO 16000 series and DIN EN ISO 16000 series consist of the following parts, under the general title Indoor air: DIN EN ISO 16000-1, General aspects of sampling strategy DIN EN ISO 16000-2, Sampling s
15、trategy for formaldehyde DIN ISO 16000-3, Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air Active sampling method DIN ISO 16000-4, Determination of formaldehyde Diffusive sampling method DIN EN ISO 16000-5, Sampling strategy for volatile organic compounds
16、 (VOCs) DIN ISO 16000-29:2015-023 DIN ISO 16000-6, Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TAsorbent, thermal desorption and gas chromatography using MS/FID DIN EN ISO 16000-7, Sampling strategy for determination of airborne asbestos fib
17、re concentrations DIN ISO 16000-8, Determination of local mean ages of air in buildings for characterizing ventilation conditions DIN EN ISO 16000-9, Determination of the emission of volatile organic compounds from building products and furnishing Emission test chamber method DIN EN ISO 16000-10, De
18、termination of the emission of volatile organic compounds from building products and furnishing Emission test cell method DIN EN ISO 16000-11, Determination of the emission of volatile organic compounds from building products and furnishing Sampling, storage of samples and preparation of test specim
19、ens DIN EN ISO 16000-12, Sampling strategy for polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polycyclic aromatic hydrocarbons (PAHs) DIN ISO 16000-13, Determination of total (gas and particle-phase) polychlorinated dioxin-like
20、biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) Collection on sorbent-backed filters DIN ISO 16000-14, Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) Ext
21、raction, clean-up and analysis by high-resolution gas chromatography/mass spectrometry DIN EN ISO 16000-15, Sampling strategy for nitrogen dioxide (NO2) DIN ISO 16000-16, Detection and enumeration of moulds Sampling by filtration DIN ISO 16000-17, Detection and enumeration of moulds Culture-based me
22、thod DIN ISO 16000-18, Detection and enumeration of moulds Sampling by impaction DIN ISO 16000-19, Sampling strategy for moulds DIN ISO 16000-21, Detection and enumeration of moulds Sampling from materials DIN ISO 16000-23, Performance test for evaluating the reduction of formaldehyde concentrations
23、 by sorptive building materials DIN ISO 16000-24, Performance test for evaluating the reduction of volatile organic compounds and carbonyl compounds without formaldehyde concentrations by sorptive building materials DIN ISO 16000-25, Determination of the emission of semi-volatile organic compounds b
24、y building products Micro-chamber method DIN EN ISO 16000-26, Sampling strategy for carbon dioxide (CO2) DIN ISO 16000-28, Determination of odour emissions from building products using test chambers DIN ISO 16000-29, Test methods for VOC detectors DIN ISO 16000-30, Sensory testing of indoor air DIN
25、ISO 16000-31, Measurement of flame retardants and plasticizers based on organophosphorus compounds Phosphoric acid ester DIN EN ISO 16000-32, Investigation of buildings for the occurrence of pollutants DIN ISO 16000-29:2015-024 The following parts are under preparation: DIN ISO 16000-20, Detection a
26、nd enumeration of moulds Determination of total spore count DIN ISO 16000-27, Determination of settled fibrous dust on surfaces by SEM (scanning electron micro-scopy) (direct method) DIN ISO 16000-33, Determination of phthalates with gas chromatography/mass spectrometry (GC-MS) DIN ISO 16000-34, Str
27、ategies for the measurement of airborne particles (PM 2,5 fraction) DIN ISO 16000-35, Measurement of polybrominated diphenylether, hexabromocyclododecane and hexa-bromobenzene DIN ISO 16000-36, Test method for the reduction rate of airborne bacteria by air purifiers using a test chamber DIN ISO 1600
28、0-37, Strategies for the measurement of airborne particles PM2,5The following part is planned: DIN ISO 16000-22, Detection and enumeration of moulds Molecular methods DIN ISO 16000-29:2015-025National Annex NA (informative) Bibliography DIN EN ISO 5492, Sensory analysis Vocabulary DIN EN ISO 8589, S
29、ensory analysis General guidance for the design of test rooms DIN 50014, Climates and their technical application Standard atmospheres DIN EN ISO 8199, Water quality General guidance on the enumeration of microorganisms by culture DIN EN ISO 9169, Air quality Definition and determination of performa
30、nce characteristics of an automatic measuring system DIN EN 61000-4-1, VDE 0847-4-1, Electromagnetic compatibility (EMC) Part 4-1: Testing and measure-ment techniques Overview of IEC 61000-4 series DIN EN 61000-4-3, VDE 0847-4-3, Electromagnetic compatibility (EMC) Part 4-3: Testing and measure-ment
31、 techniques Radiated, radio-frequency, electromagnetic field immunity test DIN EN 61000-4-4, VDE 0847-4-4, Electromagnetic compatibility (EMC) Part 4-4: Testing and measure-ment techniques Electrical fast transient/burst immunity test DIN ISO 12219-1, Indoor air of road vehicles Part 1: Whole vehicl
32、e test chamber Specification and method for the determination of volatile organic compounds in cabin interiors DIN ISO 12219-2, Indoor air of road vehicles Part 2: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials Bag meth
33、od DIN ISO 12219-3, Indoor air of road vehicles Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials Micro-scale chamber method DIN ISO 12219-4, Indoor air of road vehicles Part 4: Screening method for the determinati
34、on of the emissions of volatile organic compounds from vehicle interior parts and materials Small chamber method DIN ISO 12219-5, Indoor air of road vehicles Part 5: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials Static
35、 chamber method DIN ISO 12884, Ambient air Determination of total (gas and particle phase) polycyclic aromatic hydro-carbons Collection on sorbent-backed filters with gas chromatographic/mass spectrometric analysis DIN V EN V 13005, Guide to the expression of uncertainty in measurement DIN EN 14412,
36、 Indoor air quality Diffusive samplers for the determination of concentrations of gases and vapours Guide for selection, use and maintenance DIN EN ISO 16017-1, Indoor, ambient and workplace air Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chro
37、matography Part 1: Pumped sampling DIN EN ISO 16017-2, Indoor, ambient and workplace air Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography Part 2: Diffusive sampling DIN ISO 16362, Ambient air Determination of particle-phase polycycli
38、c aromatic hydrocarbons by high performance liquid chromatography DIN EN ISO/IEC 17025, General requirements for the competence of testing and calibration laboratories DIN ISO 16000-29:2015-026VDI 2464 Part 1, Ambient air measurement Indoor air measurement Measurement of polychlorinated biphynyls (P
39、CBs) GC/MS method for PCB 28, 52, 101, 138, 153, 180 VDI 2464 Part 2, Ambient air measurement Indoor air measurement Measurement of polychlorinated biphenyls (PCBs) HR-GC/HR-MS method for coplanar PCBs VDI 2464 Part 3, Ambient air measurement Indoor air measurement Measurement of polybrominated diph
40、enylether, hexabromocyclododecane and hexabromobenzene by GC/MS VDI 3484 Part 1, Gaseous ambient air measurements Indoor-air pollution measurements Test gases measurements Measurement of the formaldehyde concentration with the sulfite pararosaniline method VDI 3484 Part 2, Gaseous ambient air measur
41、ements Indoor-air pollution measurements Measurement of the formaldehyde concentration with the acetylacetone method VDI 3498 Part 1, Ambient air measurement Indoor air measurement Measurement of polychlorinated dibenzo-p-dioxins and dibenzofurans Method using large filters VDI 3498 Part 2, Ambient
42、air measurement Indoor air measurement Measurement of polychlorinated dibenzo-p-dioxins and dibenzofurans Method using small filters VDI 4252 Part 2, Measurement of airborne microorganisms and viruses in ambient air Active sampling of bioaerosols Separation of airborne mould on gelatine/polycarbonat
43、e filters VDI 4253 Part 2, Measurement of airborne microorganisms and viruses in ambient air Culture based method for the determination of the concentration of mould in air Indirect method after sampling with gelatine/polycarbonate filters VDI 4300 Part 1, Indoor-air pollution measurement General as
44、pects of measurement strategy VDI 4300 Part 2, Indoor-air pollution measurement Measurement strategy for polycyclic aromatic hydro-carbons (PAHs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) VDI 4300 Part 4, Indoor air polluti
45、on measurement Measurement strategy for pentachlorophenol (PCP) and -hexachlorocyclohexane (lindane) in indoor air VDI 4300 Part 5, Indoor air pollution measurement Measurement strategy for nitrogen dioxide (NO2) VDI 4300 Part 6, Measurement of indoor air pollution Measurement strategy for volatile
46、organic compounds (VOCs) VDI 4300 Part 7, Indoor-air pollution measurement Measurement of indoor air change rate VDI 4300 Part 8, Measurement of indoor air pollution Sampling of house dust VDI 4300 Part 9, Measurement of indoor air pollution Measurement strategy for carbon dioxide (CO2) VDI 4300 Par
47、t 10, Measurement of indoor air pollution Measurement strategies for determination of mould fungi in indoor environment VDI 4300 Part 11, Measurement of indoor air pollution Measurement strategies for determination of airborne particles in indoor environment Particles with equivalent diameter 2,5 m
48、VDI 4301 Part 1, Indoor air pollution measurement Determination of the concentration of nitrogen dioxide Manual photometric method (Saltzman) VDI 4301 Part 2, Indoor air pollution measurement Measurement of pentachlorophenol (PCP) and -hexachlorocyclohexane (lindane) GC/MS-method VDI 4301 Part 3, Me
49、asurement of indoor air pollution Measurement of pentachlorophenol (PCP) and -hexachlorocyclohexane (lindane) GC/ECD method DIN ISO 16000-29:2015-027VDI 4301 Part 4, Measurement of indoor air pollution Measurement of pyrethroids and piperonyl butoxide in air, house dust and solvent wipe samples VDI 4301 Part 5, Measurement o