1、I Needle size number 6 8 10 12 14 16 17 18 January 29,1997 Over-all length B D E F G H2/ A 23/16 - +Y16 C - +1/8 - +0.005 $10.01 1 30.007 10.0312 Inches Inches - Inch Inches - Inch - Inch Inch lncJ 5-1/8 3-1/16 .201 2 .O16 1-1/2 .189 .204 .138 .417 4-91 16 2-5/8 .169 I .O14 1-3/8 .I56 .164 .117 .367
2、 3-314 2 .138 1: .O12 1 .127 .134 .O97 .344 3-3/16 1-13/16 .lo8 re .O10 7/8 .lo2 .lo1 .O77 ,229 2-314 1-1/2 .O85 .O08 314 .O78 .O80 .O60 ,180 2-7/16 1-1/4 .O68 2 .O06 5/8 .O63 .O64 .O47 .166 2-5/16 1-1/8 .060+.O06 9/16 .O54 .O57 .O39 .149 2-3/16 1-118 .O52 .O04 112 .o46 .O54 .O35 .133 COMMERCIAL ITE
3、M DESCRIPTION NEEDLE, SAILMAKERS The General Services Administration has authorized the use of this commercial item description as a replacement for GGG-N-202 for all Federal agencies. i. SCOPE. This document covers needles intended to be used by sailmakers for sewing and repairing canvas. 2. CLASSI
4、FICATION. The sailmakers needles shall be of standard industry size numbers 6, 8, 10, 12, 14, 16, 17, and 18. 3. SALIENT CHARACTERISTICS. The sailmakers needles shall be forged or cast steel. All needle surfaces, the eye, and the section of the eye adjacent to the heel shall be smooth and polished.
5、Each needle shall be ground to a fine point. The edges of the triangle section shall be ground and rounded in such a manner that material fibers shall not be cut when pierced by the needle in the normal sewing operation. The eye shall be rounded and so designed that the thread will not be cut when u
6、sed under ordinary service conditions. The opening of the eye shall be centered between its lateral surfaces. Needles shall be heat treated to meet deflection require- ments without a permanent set. The needles shall conform to the dimensions listed in Table I. AMSC N/A FSC 8315 DISTRIBUTION STATEME
7、NT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- A-A-5530b 9999974 03173304 334 A-A-55306 Needle number 6 8 10 12 14 16 17 18 I b 3.2 Deflection tests. The point end of the needle shall be
8、 placed between two pieces of 3/16 inch diameter drill rod, held rigidly by a vise as shown in Figure 2, or by a vise with V block, or by other means. The distances lisi and “d“ are shown in Figure 2. The distance “SI between the drill rods shall be as shown in Table II. The tip of the needle shall
9、extend 3/32 inch beyond the point of contact with the drill rod. When the needles are held by other than drill rods, they shall be gripped 7/32 inch maximum from the point of the needle. A force shall be applied to the eye end of the needle, as close as possible to the heel, in a direction that will
10、 cause the needle to bend while the point remains stationary. A relatively sharp-edged tool such as a screwdriver or chisel shall be used in applying this force. The heel of each needle shall be deflected a linear distance “d“ as specified in Table II. This test shall be performed for each of the th
11、ree planes represented by the triangular section of each needle. Any permanent set of the needle shall constitute failure of this test. Distance (s) Distance (d) Inch - Inch 7/16 9/16 7/16 911 6 711 6 911 6 318 518 318 9/16 318 9/16 5/16 9/16 5/16 9/16 Table II. Distance and reflection 4. REGULATORY
12、 REQUIREMENTS. The offeror/contractor is encouraged to use recovered materials to the maximum extent practicable, in accordance with paragraph 23.403 of the Federal Acquisition Regulation (FAR). 5. QUALITY ASSURANCE PROVISIONS 5.1 Product conformance. The products provided shall meet the salient cha
13、racteristics of this commercial item description, conform to the producers own standards and quality assurance practices, and be the same product offered for sale in the commercial market. The Government reserves the right to require proof of such conformance. 5.2 Visual examination, Each needle sha
14、ll be examined for the defects listed below. 5.2.1 Defects. Surface (including periphery of the eye) is not smooth; evidence of imbedded foreign matter; does not have fine, sharp point; edges of triangular section not ground and rounded; eye not centered between lateral edges; eye is partially or fu
15、lly closed; sharp edge at eye (inside or outside); burrs or slivers not removed; needle is cracked or broken; evidence of pitholes, nicks, or scratches; measurement of item not as specified; any items not packaged in accordance with the contract or purchase order. 5.3 AcceDtance criteria. Acceptance
16、 criteria shall be as specified in the contract or purchase order. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55306 999997V 0373305 270 A-A-55306 6. PACKAGING 6.1 Preservation, packinn, and marking The preservation, packing, and marking sh
17、all be as specified in the contract or order. 7. NOTES 7.1 Source of Government documents. Copies of military and Federal documents are available from: Standardization Documents Order Desk Bldg. 4D 700 Robbins Avenue Philadelphia, PA 19 1 1 1 -5094 MILITARY INTERESTS: Custodians Army - GL Navy - NU
18、Air Force - 99 Review Activities Air Force - 82,45 CIVIL AGENCY COORDINATING ACTIVITIES: GSA - FSS Jus - FPI DC PREPARING ACTIVITY: DLA - CT Project 8315-0382 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-55306 9999974 017330b 107 A-A-55306 SECTION X-X SECTION Y-Y SECTIbhi 2-2 FIGURE 1. SAILMAKERS NEEDLE FIGURE 2. DEFLECTION TEST 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1