1、A-A-55433 m 9999974 0155454 829 m I INCH-POUND 1 A-A- 5 54 3 3 August 26, 1993 COMMERCIAL ITEM DESCRIPTION LIGHT, CHEMILUMINESCENT, 15 IN - 8 HR - A, G The General Services Administration has authorized the use of this commercial item description. Abc tract This description covers 8 hour 15 inch che
2、miluminescent lights (commonly known as a light wand) used for a variety of lighting, marking, and identification purposes. Salient characteristics. 1. Color. The colors of the chemiluminescent lights described in this CID are blue and white. The color wand required shall be identified in the Part I
3、dentification Number (PIN) paragraph of this CID. Beneficial comments, recommendations, additions, deletions, clarifications, etc., and any data which may improve this document should be sent to: Commander, Space and Naval Warfare Command, ATTN: SPAWAR 003-114/031, Washington, DC . 20363. AMSC N/A D
4、ISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. FSC 6260 Licensed by Information Handling ServicesA-A-55433 m 9999974 0355455 7b5 A-A-5 5 4 3 3 2. Desisn. The chemiluminescent light shall be an elongated wand having an overall length of 16 inches plus 0.340 inche6 mi
5、nus 0.200 inches. The diameter shall be .O700 inches plus or minus 0.060 inches and have a flat base on one end. Each end shall also have an extended boss .406 inches nominal wide, with a hole .188 inches nominal. Wand shall be compatible with Handle, Light, Safety, NSN 6260-01-255-3345. 3. Interior
6、. The chemiluminescent lights specified in this Commercial Item Description shall produce a level of light intensity as specified in Table I for a specified length of time (8 hours). 4. Material Safety Data Sheet. Manufacturer shall provide evidence in the form of a Material Safety Data sheet (MSDS)
7、 (Fed-Std-313) that the components shall not be highly toxic, toxic, corrosive or irritant in terms of the definitions and tests in Code of Federal Regulations, Title 16, Part 1500 (Federal Hazardous Substances Act). 5. Test Criteria. Illuminance must meet or exceed the data presented in Table I. Af
8、ter Ageing Test, illuminance must meet or exceed data in Table II. Activated by manually flexing the plastic tube, breaking the inner vial and shaking to combine components. Plastic tube shall not leak and vial will not break when subjected to an external pressure equivalent to 30,000 feet at 75 deg
9、rees F in vacuum chamber. Must withstand a free fall, while still in wrapper, from a height of 8.5 feet on a hard surface (concrete) without activating or leakage. 6. Test Conditions. a. Meter: Digital Photometer, TEKTRONIX, Model 516, Sensor Probe J6501. All meters traceable t NIST. 1 b. Wand to Me
10、ter Distance: 1.50 5 0.02 inches. c. Temperature stabilization: Wands, while still in sealed foil wrappers, will be placed in a water bath at test temperature for a minimum of one (1) hour before activation. d. activation. Remove wand from sealed foil wrapper immediately before Light wand shall be h
11、andled by cap end during testing. 2 Licensed by Information Handling ServicesA-A-55433 9999974 015.5456 bT1 W A-A- 5 5 4 3 3 e. Activation method: Bend; agitate for fifteen (15) seconds. f. Wands shall be agitated for ten (10) seconds before each reading. g. Wands kept under cover or in darkness; ma
12、y be exposed to light during movement to and from light meter. h. All meter readings made in darkness. i. Meter kept at 75 degrees F for all tests. j. Temperature tolerances: plus or minus 2F. k. Holder, wand test fixture in accordance with DGSC drawing, DGSCV-91-03, Part Number 2. (Enclosure 1) 1.
13、Chemiluminescent lights shall be held in a vertical position with cap end down when light output measurement is made. m. Ageing Test - test conditions to be added at a future revision date. Contractor Certification. The contractor shall certify, and maintain objective quality evidence that the produ
14、ct offered to the Government meets the salient characteristics of this description and that the product conforms to the producers own drawings, specifications, standards, and quality assurance practices and is the same produced as the manufacturers current product offered by the contractor in the co
15、mmercial marketplace for at least one year preceding the solicitation. The Government reserves the right to require proof of such conformance prior to first delivery and thereafter as may be otherwise provided for under the provisions of the contract. Metric Products. Products manufactured to metric
16、 dimensions will be considered on an equal basis with those manufactured using inch-pound units, provided they fall within specified tolerances using conversion tables contained in the latest revision of Federal Standard No. 376, and all other requirements of this Commercial Item Description are met
17、. If a product is manufactured to metric dimensions and those dimensions exceed the tolerances specified in the inch-pound units, a request should be made to the Contracting Officer to determine if the product is acceptable. of accepting or rejecting the product. The Contracting Officer has the opti
18、on 3 Licensed by Information Handling ServicesA-A-5 5 4 3 3 A-A-55433 9999974 0355457 538 O m . l-l 4 Nr- . ON O r-4 Nm ON O 4N e-3 Oe r- Pr- em oa3 NN Nw 03. 44 4m 44 o4 . e4 4w o4 r-m da3 o4 . o4 . . .m c W 4 . r- . N * 4 4143 om O0 m eP 4m o4 r- mo 4P 04 a3 o34 NA om . m -0 e4 ou) 4m O H W u z W
19、Y vlm om O0 wm or- O0 om 000 O0 . . . . nn ma ww . rl 8 O bl W X H * c IWI I I . m o) Y lu R O -84 v) -84 3 a i! al k I Y 1 hl m Y lu a o) a a A o) a O Y Y lu o) 4 a H m n m 4 Licensed by Information Handling ServicesIn W I- D z $ a WM W W I- i L t- I 7 O O 21 ;3 s U * m W tY 3 t- X G t- 0 W t- Q 7
20、a H 3 2 w FI _J O I Licensed by Information Handling ServicesA-A-5 5 4 3 3 Resulatorv Reauirements. The offeror/contractor is encouraged to use recovered materials in accordance with Public Law 94-580 to the maximum extent practicable. Quality Assurance. Foil Leakase. Samples will be tested for foil
21、 leakage by application of 6 psi air pressure into the inside of the foil wrap while submerged under water. A steady stream of air bubbles coming from any portion of the foil, except where the foil has been penetrated by the air supply shall be classified as an airtight foil failure. Shelf Life. Eac
22、h chemiluminescent light shall have a minimum of 42 months life remaining at the time delivery to the Government and must have been manufactured within 6 months of the date of delivery to the Government. Fluid Level. The vertical fluid level, when measured from the exterior of the flat base shall be
23、 no less than 12.2 inches. Preservation, Packaqins, Packins, Labelins, and Markinq. The preservation, packaging, packing, labeling and marking shall be as specified in the contract or order. Foil wrapping and all other packaging shall be marked with Foil wrapping shall be color coded and contain ope
24、rating manufacturers lot number and expiration date. instructions. CID based Part Identification Number. The following Part Identification Numbering procedure is for Government purposes and does not constitute a requirement for the contractor. A-A-XXXXX-X COLOR A=BLUE G=WHITE L CID NUMBER 6 Licensed
25、 by Information Handling ServicesA-A-55433 7777774 0355460 O22 = Notes. Orderinq data. Acquisition documents must specify the following: a. Title, number, part identification number with applicable color code letter, and date of this document. b. Material Safety Data Sheet (MSDS) shall be provided t
26、o Contracting Officer prior to award (FAR 52.233-3 and MSDS Page 2). c. Contracting Officer may request proof of certification of commercial item prior to first contract delivery (See Contractor Certification, Page 3). MILITARY INTEREST: CIVIL AGENCY COORDINATING ACTIVITY: MILITARY COORDINATING ACTIVITY: GSA-FSS Custodians Navy - EC Air Force-99 Reviewinq Activities DLA-GS PREPARING ACTIVITY: Navy-EC AGENT: DLA-GS PROJECT NO. 6260-1025 User Activities Navy-YD FSC 6260 7 Licensed by Information Handling Services
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1