1、 AMSC N/A FSC 5945 AN3372 REVISION 6 23 SEPTEMBER 2010 SUPERSEDING REVISION 5 15 January 2002 DETAIL SPECIFICATION SHEET RELAY, 200 AMP, 2PST, CLASS O, UNSEALED Inactive for new design after 25 November 1957. No superseding document. This specification is approved for use by all Departments and Agen
2、cies of the Department of Defense. The requirements for acquiring the relay described herein shall consist of this specification and the latest issue of MIL-PRF-6106. FIGURE 1. Configurations and dimensions. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without lice
3、nse from IHS-,-,-AN3372 REVISION 6 Inches mm Inches mm .010 0.025 .907 2.303 .031 0.079 1.562 3.969 .062 0.158 2.625 6.668 .093 0.238 2.700 6.858 .250 0.635 2.886 7.330 .265 0.673 3.250 8.255 .266 0.675 3.468 8.810 .375 0.952 3.687 9.366 .407 1.034 3.718 9.445 .689 1.750 4.062 10.318 .719 1.826 NOTE
4、S: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerances are .016 (0.040 mm). FIGURE 1. Configurations and dimensions - Continued. REQUIREMENTS Operating cycles: 50,000 minimum. Contact data: Contact voltage drop: Not app
5、licable. Coil temperature rise: Not applicable. Load ratings: See Table I. TABLE I - Rated contact load (per pole). Type of load Amperes Resistive (28 Volts DC) 200 Resistive (400 Hz, 115 Volts AC) 150 Inductive (28 Volts DC) 100 Motor (28 Volts DC) 150 Motor (400 Hz, 115 Volts AC) 100 1/ For resist
6、ive load tests, one set of contacts shall be tested with rated resistive DC load and the other set of contacts shall be tested with rated resistive AC load. Overload current: Not applicable. Rupture current: Not applicable. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted witho
7、ut license from IHS-,-,-AN3372 REVISION 6 Coil data: Nominal coil voltage: 28 volts. Maximum operating voltage: 29 volts. Pickup voltage: 20 volts. Hold voltage: 7 volts Dropout voltage: 1.5 volts. Rated duty: Continuous. Coil current: 0.8 amperes, maximum. Physical data: Weight: 2.5 pounds, maximum
8、. Qualification by similarity: See MIL-PRF-6106. Retention of qualification: To retain qualification, the manufacturer shall submit group A acceptance reports on a yearly basis to the qualifying activity. Quality conformance inspection: Performance of groups B and C tests are not applicable. Part or
9、 Identifying Number (PIN): AN3372-1. Supersession information: Supersedes USAF Specification Number 32538. Referenced documents. this document references the following: MIL-PRF-6106 Custodian: Preparing activity: Air Force - 85 DLA - CC DLA - CC (Project 5945-2010-028)Review activity: Air Force - 99
10、 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-