1、REVISIONS LTR DESCRIPTION DATE APPROVED A Change CAGE code from 037Z3 to 16236 and e-mail address for comments. Removed approved sources requirements. 4 June 2008 A. Abdouni Prepared in accordance with ASME Y14.100 Detail Drawing REV PAGE REV A A A A REV STATUS OF PAGES PAGE 1 2 3 4 PREPARED BY PMIC
2、 N/A William Carpenter DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OHIO 43218-3990 CHECKED BY TITLE Ernest Brown APPROVED BY Abdo Abdouni HOSE ASSEMBLY, INTERNAL SUPPORT COIL, FOR VACUUM AND SUCTION HOSES SIZE CAGE CODE 16236 DWG. NO.08001 Original date of drawing 29 January 2008 A REV A PAGE 1 OF 4 A
3、MSC N/A 4720-H002-001 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. Internal support coil dash number SAE hose size Coil OD inches (mm) V06 -6 .34 (8.6) V08 -8 .42 (10.7) V10 -10 .51 (13.0) V12 -12 .73 (18.5) V16 -16 .94 (23.
4、9) V20 -20 1.19 (30.2) V24 -24 1.44 (36.6) V32 -32 1.88 (47.8) NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. 3. This coil is recommended for vacuum and suction service hose assemblies. 4. Smaller hose sizes coil should slide easily into hose. Larger hose s
5、izes may require the spring be compressed. FIGURE 1. Internal support coil. 16236 08001 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 A REVA PAGE2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. SCOPE Scope. This draw
6、ing outlines the requirements for an internal coil for use in hose assemblies. Qualification inspection. Qualification inspection for hose accessories specified herein shall not be required. REQUIREMENTS Design configuration. The design, construction, and physical dimensions shall be as specified on
7、 figure 1. Material: Metal coil. Metal coils shall meet the requirements of American Iron and Steel Institute (AISI) 301, AISI 302, or AISI 304 with the following requirements: Tensile: 1700 psi min. Yield: 1400 psi min 2% offset. Elongation: 2% min (in 2 inches ). All the coils supplied to this dra
8、wing shall be free from seams, pits, die scratches, slivers, burrs, sharp edges, or other defects that may affect service life. Internal coil length. The coil shall be cut to overall assembly length minus the nipple intrusion. Marking: The Part or Identifying Number (PIN) shall be marked on the pack
9、age in accordance with MIL-STD-1285. The marking shall include the complete DSCC PIN, manufacturers name or CAGE code, and date code. The PIN shall be constructed using the following format: 08001 -V03 02 DSCC Internal Length Requirement support in feet Drawing coil dash number PACKAGING Packaging.
10、For acquisition purposes, the packaging requirements shall be as specified in the contract or order. When packaging of material is to be performed by DoD or in-house contractor personnel, these personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packagin
11、g requirements are maintained by the Inventory Control Points packaging activities within the Military Service or Defense Agency, or within the Military Departments System Command. Packaging data retrieval is available from the managing Military Departments or Defense Agencys automated packaging fil
12、es, CD-ROM products, or by contacting the responsible packaging activity. 16236 08001 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 A REVA PAGE3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SIZE CAGE CODE DWG NO. DSCC drawing use. Intern
13、al support coils in accordance to this drawing are intended for use when military specifications do not exist and qualified military connectors that will perform the required function are not available for OEM application. This drawing is intended exclusively to prevent the proliferation of unnecess
14、ary duplicate specifications, drawings, and stock catalog listings. Acquisition requirements. Acquisition documents should specify the following: a. Complete PIN. b. Requirements for certificate of compliance, if applicable. c. Requirements for notification of change of product or process to contrac
15、ting activity, if applicable. d. Packaging requirements. Comments. Comments on this drawing should be directed to Defense Supply Center, Columbus, ATTN: DSCC-VAI, P.O. Box 3990 Columbus, Ohio 43218-3990 or telephone (614) 692-0565, facsimile (614) 692-6940 or emailed to FluidFlowdla.mil. 16236 08001 DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 A REVA PAGE4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-