1、 AMSC N/A 5935-E838-002 REVISIONS LTR DESCRIPTION DATE APPROVED REV PAGE REV STATUS OF PAGES REV PAGE 1 2 3 4 5 PMIC G PREPARED BY DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OHIO 43218-3990 Jeremy Funk Original date of drawing 04 September 2013 CHECKED BY TITLE Jeremy Funk CONNECTOR, ELECTRICAL, COAX
2、IAL, RADIO FREQUENCY, SOCKET CONTACT SERIES SMPM APPROVED BY Abdonasser Abdouni SIZE CAGE CODE DWG. NO. 10020 A 037Z3 REV PAGE 1 OF 5 CURRENT DESIGN ACTIVITY CAGE CODE 037Z3 HAS CHANGED NAMES TO: DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 Provided by IHSNot for ResaleNo reproduction or networki
3、ng permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 10020 REV PAGE 2 Inches mm .047 1.19 .086 2.18 .095 2.41 .124 3.15 .290 7.37 PIN Cable accommodation Cable overall diameter 10020-1 M17/133-RG405 1/ .086 inch 10020-2 M17/
4、151-00001 1/ .047 inch 1/ These connectors accept all cables listed on the reference specification sheet. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. 3. All undimensioned pictorial configurations are for reference purposes only. 4. Special tools shall be
5、 required for assembly. Contact manufacturer. FIGURE 1. General configuration 1 and 2. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 10020 REV PAGE 3 ENGINEERING
6、 DATA Nominal impedance: 50 ohms Frequency range: DC to 40 GHz. -1 DC to 65 GHz -2 RF leakage: -80 dB mated pair typical. Voltage rating: 217 V rms maximum at sea level: 42 V rms at 70,000 feet. Operating temperature: -65C to +165C. REQUIREMENTS (after assembly): (Requirements of drawing 84148 are a
7、pplicable). Dimensions and configuration: See figure 1. Mating connector in accordance with figure 1 of drawing 10019. Mating interface: In accordance with MIL-STD-348. Force to engage: 8 pounds, maximum (full detent shroud in accordance with drawing 10019). Force to disengage: 4.5 pounds, minimum (
8、full detent shroud in accordance with drawing 10019). Center contact inspection conditions (after heat treat) Oversize test pin: Test pin diameter: .0135 inch +.0001/-.0000 inch. Insertion depth: .030 inch minimum, .070 inch maximum. Number of insertions: 3. Insertion force test: Test pin diameter:
9、.0130 inch +.0001/-.0000 inch. Insertion force: 12 ounces, maximum. Insertion depth: .030 inch minimum, .045 inch maximum. Withdrawal force test: Test pin diameter: .0110 +0000/-.0001 inch. Withdrawal force: 0.25 ounce, minimum. Insertion depth: .030 inch minimum, .045 inch maximum. Radial misalignm
10、ent: Not applicable. Axial misalignment: Not applicable. Coupling proof torque: Not applicable. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 10020 REV PAGE 4 He
11、rmetic seal: Not applicable. Leakage (pressurized connectors): Not applicable. Radial torque: Not applicable. VSWR: Straight Connector DC to 26.5 gigahertz: 1.15:1 maximum. 26.5 to 40 gigahertz: 1.30:1 maximum. VSWR procedure. The VSWR shall be measured in accordance with the following procedure or
12、a method acceptable to the Government. Part should be tested using a Network Analyzer with the Time Domain (TDR) option installed. The recommended network analyzer systems include Hewlett Packard HP 8510. Wiltron 360 or equivalent. The printer/plotter and the computer should be any unit compatible t
13、o the system. Calibration of the system should be performed using the manufacturers calibration kits and the recommended calibration procedures. The frequency range shall be DC to 40 GHz. The VSWR calibration test setup shall be verified using the manufacturers verification kits. The device under te
14、st (DUT) shall be attached to the appropriate cable. An adapter capable of performing to 40 GHz such shall be attached to the calibrated test port of the analyzer. The DUT shall be mated to the test adapter. The VSWR of the DUT shall be measured using the procedures described in the manufacturers op
15、erating instructions. The time domain shall be used to remove the effects of the test adapter. The output shall be generated using the appropriate printer/plotter. Moisture resistance: MIL-STD-202, method 106, except step 7b shall be omitted. Resistance shall be 1,000 megohms within 5 minutes after
16、removal from humidity. Contact resistance (in milliohms, maximum): Initial Center contact 6.0 Outer contact 2.0 Outer conductor to connector body 0.5 Dielectric withstanding voltage at sea level: 325 V rms minimum. 80 V rms at 70,000 feet. Vibration, high frequency: MIL-STD-202, method 204, test con
17、dition D (When mated with full detent shroud in accordance with 10019). Vibration, random: MIL-STD-202, method 214, test condition F (When mated with full detent shroud in accordance with 10019) duration 15 minutes, minimum. Provided by IHSNot for ResaleNo reproduction or networking permitted withou
18、t license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 10020 REV PAGE 5 Corona level: Altitude: 70,000 feet. 125 V rms, minimum. Insulation resistance: 5,000 megohms minimum when tested in accordance with MIL-PRF-39012. Altitude: Sea level to 70
19、,000 feet. Solderability (when applicable): Applicable. Shock (specified pulse): MIL-STD-202, method 213, test condition I (When mated with full detent shroud in accordance with 10019). Thermal shock: MIL-STD-202, method 107, test condition B (except high temperature to be +165C or maximum high temp
20、erature of cable). RF high potential withstanding voltage: 200V rms minimum at sea level. Frequency: 5 MHz. Leakage current: Not applicable. Cable retention: 30 pounds minimum: torque, not applicable (10020-1). 20 pounds minimum: torque, not applicable (10020 -2). Coupling mechanism retention force:
21、 Not applicable. Durability: 100 cycles. RF insertion loss: 0.12 Frequency (GHz) dB Part or Identifying Number (PIN): 10020-X (See figure 1). DSCC drawing PIN 1/ Cable accommodation 10020 1 M17/133-RG405 : .086 inch 10020 2 M17/151-00001 : .047 inch 1/ Parts must be purchased to this DSCC PIN to ass
22、ure that all performance requirements and tests are met. Materials: Contacts and adapter housing: Beryllium copper in accordance with ASTM B196/B196M, gold plated to a minimum thickness of 50 microinches (1.27 m) in accordance with MIL-DTL-45204, type II, grade C, class 1, over 50 microinches (1.27
23、m) minimum of nickel in accordance with MIL-DTL-38999, class 1. Shroud in accordance with drawing 10019. Approved sources. Approved sources of supply will be listed herein. Approved sources are required to be a QPL source on MIL-PRF-39012 or MIL-PRF-31031. Additional sources will be added as they be
24、come available. The vendors listed on the requirements drawing agree to this drawing and a certificate of compliance has been submitted to DLA Land and Maritime - VAI. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH 43218-3990 SIZE CAGE CODE DWG NO. A 037Z3 10020 REV PAGE 6 Vendor CAGE Vendor Name and Number address 95077 SV Microwave, Inc. 2400 Centrepark West Drive West Palm Beach, Florida 33409-6469 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-