1、 MIL-DTL-13777/3B 11 May 2011 SUPERSEDING MIL-C-13777/3A 1 September 1966 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL 16, 17, 18, 19, AND 20 CONDUCTORS This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquirin
2、g the product described herein shall consist of this specification sheet and MIL-DTL-13777. REQUIREMENTS: Dimensions and configurations: See applicable figure and design data for the following cable types. The cable types are specified in table I. Design data information is specified in table II. TA
3、BLE I. Cable types. 160636 S160878S 161065S S161375S 170752 170874 180675 180848 S190875 S190965S 191110S 191140 200935 AMSC N/A FSC 6145 Inactive for new design after 1 July 2002. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13
4、777/3B 2 TABLE II. Design data.1/Design data Type designation 160636 S160878S 161065S Figure number 1 2 3 Total wires 16 16 16 Number of conductors & AWG # 16/#20 8/#18 8/#18S 12/#18 4/#18 Insulation Min average thickness 0.012” 0.015” 0.015” Spark test voltage 3000 3000 3000 Inspection test voltage
5、 1500 1500 1500 Coaxial jacket insulation (a) Minimum average thickness Cabling Layer 1 Filler Filler Filler Layer 2 (a) Number of wires 5 6 4 (b) AWG # #20 #18 #18S (c) Maximum lay 2.0” 2.50” 3.75” Layer 3 (a) Number of wires 11 2 8 12 (b) AWG # #20 #18 #18S #18 (c) Maximum lay 4.5” 5.00” 6.00” She
6、ath Number of layers 2 1 2 Total thickness min. 0.109” 0.080” 0.100” Minimum OD cable 0.616” 0.863” 1.050” Maximum OD cable 0.656” 0.893” 1.080” Maximum weight (lbs./1000ft.) 538 See notes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-
7、,-,-MIL-DTL-13777/3B 3 TABLE II. Design data Continued.1/ Design data Type designation S161375S 1707522/1708743/ Figure number 4 5 5 Total wires 16 17 17 Number of conductors & AWG # 2/#18S 10/#18S 4/#6 17/#18 17/#16 Insulation Minimum average thickness 0.015” 0.060” 0.015” 0.015” Spark test voltage
8、 3000 7500 3000 3000 Inspection test voltage 1500 2500 1500 1500 Cabling Layer 1 Filler Filler (a) Number of wires 2 (b) AWG # #184/(c) Maximum lay 3.00” Layer 2 (a) Number of wires 5 5 4 6 6 (b) AWG # #185/#18S #6 #18 #16 (c) Maximum lay 8.00” Layer 3 (a) Number of wires (b) AWG # #18 #16 (c) Maxim
9、um lay 5.00” 6.00” Sheath Number of layers 2 2 2 Total thickness minimum 0.100” 0.110” 0.109” Minimum OD cable 1.360” 0.737” 0.849” Maximum OD cable 1.390” 0.767” 0.899” See notes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-D
10、TL-13777/3B 4 TABLE II. Design data Continued.1/ Design data Type designation 180675 180848 S190875 6/ Figure number 6 7 8 Total wires 18 18 19 Number of conductors & AWG # 18/#20 14/#18 4/#16 19/#18 Insulation Minimum average thickness 0.015” 0.015” 0.015” Spark test voltage 3000 3000 3000 Inspecti
11、on test voltage 1500 1500 1500 Cabling Layer 1 Filler Filler Filler Layer 2 (a) Number of wires 6 2 4 7 (b) AWG # #20 #18 #16 #18 (c) Maximum lay Layer 3 (a) Number of wires 12 12 (b) AWG # #20 #18 #18 (c) Maximum lay 5.00” Sheath Number of layers 1 2 1 Total thickness minimum 0.080” 0.098” 0.094” M
12、inimum OD cable 0.650” 0.823” 0.850” Maximum OD cable 0.700” 0.873” 0.900” See notes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/3B 5 TABLE II. Design data Continued.1/ Design data Type designation S190965S 191110S
13、Figure number 9 8 Total wires 19 19 Number of conductors & AWG # 8/#18S 11/#18 7/#20 12/#20S Insulation Minimum average thickness 0.015” 0.012” Spark test voltage 3000 3000 Inspection test voltage 1500 1500 Cabling Layer 1 Filler Filler Layer 2 (a) Number of wires 8 7 (b) AWG # #18 #20 (c) Maximum l
14、ay 2.50” 4.0” Layer 3 (a) Number of wires 8 3 12 (b) AWG # #18S #18 #20S (c) Maximum lay 5.00” 8.0” Sheath Number of layers 1 2 Total thickness min 0.080” 0.140” Minimum OD cable 0.950” 1.080” Maximum OD cable 0.980” 1.140” See notes at end of table. Provided by IHSNot for ResaleNo reproduction or n
15、etworking permitted without license from IHS-,-,-MIL-DTL-13777/3B 6 TABLE II. Design data Continued.1/ Design data Type designation 191140 200935 Figure number. 8 10 Total wires 19 20 Number of conductors & AWG # 19/#12 13/#18 7/#15 Insulation Minimum average thickness 0.020” 0.015” Spark test volta
16、ge 4000 3000 Inspection test voltage 2000 1500 Cabling Layer 1 Filler Filler Layer 2 (a) Number of wires 7 7 (b) AWG # #12 #15 (c) Maximum lay 3.25” Layer 3 (a) Number of wires 12 13 (b) AWG # #12 #18 (c) Maximum lay 4.25” Sheath Number of layers 2 2 Total thickness minimum 0.098” 0.125” Minimum OD
17、cable 1.115” 0.920” Maximum OD cable 1.165” 0.950” Maximum weight (lbs/1000ft.) 540 1/ Jacketed coaxial wires 2/ 11 & 1 filler 3/ 11 W/fillers 4/ Shield applied over twisted pair of AWG #18 Maximum twist lay 3.00” 5/ Assembly with max lay of 3.00” 6/ 12 W/filler Changes from previous issue. Marginal
18、 notations are not used in this revision to identify changes with respect to the previous issues due to the extensiveness of the changes. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/3B 7 FIGURE 1. Cable type (160636). Provided by IH
19、SNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/3B 8 FIGURE 2. Cable type (S160878S). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/3B 9 FIGURE 3. Cable type (161065S). Provided by IHS
20、Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/3B 10 FIGURE 4. Cable type (S161375S). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/3B 11 FIGURE 5. Cable types (170752, 170874). Provid
21、ed by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/3B 12 FIGURE 6. Cable type (180675). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/3B 13 FIGURE 7. Cable type (180848). Provided
22、 by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/3B 14 NOTE: *Double circle indicates shielded conductors. FIGURE 8. Cable types (S190875, 19110S*, 191140). Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro
23、m IHS-,-,-MIL-DTL-13777/3B 15 NOTE: Double circle indicates shielded conductors. FIGURE 9. Cable type (S190965S). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/3B 16 FIGURE 10. Cable type (200935). Provided by IHSNot for ResaleNo repr
24、oduction or networking permitted without license from IHS-,-,-MIL-DTL-13777/3B 17 CONCLUDING MATERIAL Custodians: Preparing activity: Army AR DLA CC Navy SH Air Force 85 (Project 6145-2011-005) DLA CC Review activities: Army CE, CR, MI Navy MC Air Force 19 Note: The activities listed above were inte
25、rested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information using the Assist Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-