1、 DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, RECEPTACLE, THREADED, DUMMY STOWAGE, SERIES III, METRIC This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this
2、 specification sheet and MIL-DTL-38999. FIGURE 1. Receptacle, classes F, G, J, K, M, P, R, S, T, W, X and Z. AMSC N/A FSC 5935 mm Inches 0.13 .01 12.40 .49 12.95 .51 14.50 .57 14.73 .58 METRIC MIL-DTL-38999/22H 14 June 2013 SUPERSEDING MIL-DTL-38999/22G 10 July 2008 Provided by IHSNot for ResaleNo r
3、eproduction or networking permitted without license from IHS-,-,-MIL-DTL-38999/22H 2 Dimensions Shell size Shell size code P .20 PP .20 R1 (see note 4) R2 (see note 5) 9 A (see note 6) 3.25 (.128) 5.49 (.216) 18.26 (.719) 15.09 (.594) 9 AA (see note 7) 3.25 (.128) 5.49 (.216) 18.26 (.719) 15.09 (.59
4、4) 11 B 3.25 (.128) 4.93 (.194) 20.62 (.812) 18.26 (.719) 13 C 3.25 (.128) 4.93 (.194) 23.01 (.906) 20.62 (.812) 15 D 3.25 (.128) 4.39 (.173) 24.61 (.969) 23.01 (.906) 17 E 3.25 (.128) 4.93 (.194) 26.97 (1.062) 24.61 (.969) 19 F 3.25 (.128) 4.93 (.194) 29.36 (1.156) 26.97 (1.062) 21 G 3.25 (.128) 4.
5、93 (.194) 31.75 (1.250) 29.36 (1.156) 23 H 3.91 (.154) 6.15 (.242) 34.93 (1.375) 31.75 (1.250) 25 J 3.91 (.154) 6.15 (.242) 38.10 (1.500) 34.93 (1.375) FIGURE 1. Receptacle, classes F, G, J, K, M, P, R, S, T, W, X and Z Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted
6、without license from IHS-,-,-MIL-DTL-38999/22H 3 Dimensions Shell size Shell size code S .3 V + 0.00 - 0.13 V + 1.4 - 0.0 W .3 W 9 A (see note 6) 23.8 (.937) 20.83 (.820) 19.5 (.768) 2.5 (.098) 3.65 / 2.2 (.144 /.087) 9 AA (see note 7) 23.8 (.937) 20.83 (.820) 19.5 (.768) 2.5 (.098) 3.65 / 2.2 (.144
7、 /.087) 11 B 26.2 (1.031) 20.83 (.820) 19.5 (.768) 2.5 (.098) 3.65 / 2.2 (.144 /.087) 13 C 28.6 (1.126) 20.83 (.820) 19.5 (.768) 2.5 (.098) 3.65 / 2.2 (.144 /.087) 15 D 31.0 (1.220) 20.83 (.820) 19.5 (.768) 2.5 (.098) 3.65 / 2.2 (.144 /.087) 17 E 33.3 (1.311) 20.83 (.820) 19.5 (.768) 2.5 (.098) 3.65
8、 / 2.2 (.144 /.087) 19 F 36.5 (1.437) 20.83 (.820) 19.5 (.768) 2.5 (.098) 3.65 / 2.2 (.144 /.087) 21 G 39.7 (1.563) 20.07 (.790) 18.7 (.736) 3.2 (.126) 4.35 / 2.9 (.171 / .114) 23 H 42.9 (1.689) 20.07 (.790) 18.7 (.736) 3.2 (.126) 4.35 / 2.9 (.171 / .114) 25 J 46.0 (1.811) 20.07 (.790) 18.7 (.736) 3
9、.2 (.126) 4.35 / 2.9 (.171 / .114) NOTES: 1. Dimensions are in millimeters. Inch equivalents are given for information only. 2. Flange is solid. 3. Dummy receptacles are used when unmated plugs must be protected. 4. Dimensions required for intermountability with front or rear mounting series I. 5. D
10、imensions required for intermountability with front mounting series II. 6. Shell size code A is for use with size 9 plug mating key polarizations C, E and N, only. 7. Shell size code AA is for use with size 9 plug mating key polarizations A, B and D, only. FIGURE 1. Receptacle, classes F, G, J, K, M
11、, P, R, S, T, W, X and Z Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-38999/22H 4 SHELL SIZE 9, SHELL SIZE CODE A FIGURE 2. Receptacle, keyway arrangements, classes F, G, J, K, M, P, R, T, S, W, X and Z (shell size 9). Provided
12、by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-38999/22H 5 SHELL SIZE 9, SHELL SIZE CODE AA NOTES: 1. Dimensions are in millimeters. 2. Inch equivalents are given for information only. FIGURE 2. Receptacle, keyway arrangements, classes F, G, J, K, M,
13、 P, R, T, S, W, X and Z (shell size 9) - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-38999/22H 6 SHELL SIZES 11, 13 AND 15 Shell size A dia B dia 11 15.88/15.60 (.625/.614) 14.66/14.45 (.577/.569) 13 19.66/19.38 (.774/.763) 17.
14、50/17.30 (.689/.681) 15 22.84/22.56 (.899/.888) 20.65/20.44 (.813/.805) NOTES: 1. Dimensions are in millimeters. 2. Inch equivalents are given for information only. FIGURE 3. Receptacle, keyway arrangement, classes F, G, J, K, M, P, R, S, T, W, X and Z (shell sizes 11, 13 and 15). Provided by IHSNot
15、 for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-38999/22H 7 SHELL SIZES 17, 19, 21, 23 AND 25 Shell size A dia B dia 17 26.01/25.73 (1.024/1.013) 23.85/23.64 (.939/.930) 19 28.63/28.40 (1.127/1.118) 26.55/26.31 (1.045/1.036) 21 31.85/31.57 (1.254/1.243) 29.70/
16、29.49 (1.169/1.161) 23 35.03/34.75 (1.379/1.368) 32.85/32.66 (1.293/1.286) 25 38.20/37.92 (1.504/1.493) 36.00/35.84 (1.417/1.411) FIGURE 4. Receptacle, keyway arrangement, classes F, G, J, K, M, P, R, S, T, W, X and Z (shell sizes 17, 19, 21, 23 and 25). Provided by IHSNot for ResaleNo reproduction
17、or networking permitted without license from IHS-,-,-MIL-DTL-38999/22H 8 REQUIREMENTS: Dimensions and configurations: See figures 1 thru 4. Interface dimensions shall conform to MIL-DTL-38999, except as noted. This connector mates with MIL-DTL-38999/26, MIL-DTL-38999/29, MIL-DTL-38999/30, and MIL-DT
18、L-38999/31. Air leakage: Testing shall be in accordance with EIA-364-02, except the minimum period of measurement shall be 10 seconds. The air leakage rate shall be no greater than 1 atmospheric cubic inch per hour (4.55 X 10-3 cm3/s) Stowage receptacles shall be mated to connectors having either co
19、ntacts or inserts removed so that a pressure of 10 lbft/in2 (.703 Kg/cm2 ) can be applied against the insides of the stowage receptacles. Qualification (all classes). Qualification shall be in accordance with MIL-DTL-38999, conducted on two samples of each shell size, except only the following seque
20、nce of tests shall be required: Examination of product Coupling torque Dynamic salt spray (corrosion) Air leakage (see requirement) Visual and mechanical Qualification (classes J and M only): Qualification shall be in accordance with MIL-DTL-38999, except that in addition to the test sequence specif
21、ied for all classes above, the following tests shall be required: Temperature cycling Hydrolytic stability Group A sampling inspection. Sampling for group A inspection shall be as specified in table I. TABLE I. Group A sampling plan. Lot size Sampling size 1 to 13 100 percent 14 to 150 13 units 151
22、to 280 20 units 281 to 500 29 units 501 to 1,200 34 units 1,201 to 3,200 42 units 3,201 and up 54 units Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-38999/22H 9 Part or Identifying Number (PIN) example: D38999/ 22 B W DoD number prefix Spe
23、cification sheet number Shell size code * Class * NOTE: For shell size 9 only: Shell size code A is for use with plugs with mating key polarizations “C”, “E” or “N”. Shell size code AA is for use with plugs with mating key polarizations “A”, “B” or “D”. NOTE: The term PIN is equivalent to the term (
24、part number, identification number, and type designator) which was previously used in this specification. Change effectivity. Unless otherwise specified by the preparing activity and/or the qualifying activity, all changes from the previous revision of this specification sheet shall become effective
25、 within 90 days of the date of publication of the latest revision. If unable to implement changes within the 90 day time period, the manufacturer or value added distributor shall notify the qualifying activity. The qualifying activity shall determine if an extension may be granted. Disposition of st
26、ock. Unless otherwise specified by the qualifying activity and coordinated with the preparing activity, qualified manufacturers and their selling agents or distributors may continue to ship stowage receptacles which were manufactured in accordance with the previous revision of this specification she
27、et for a period of 18 months from the date of the latest revision, provided that form, fit and function are not affected. Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a conv
28、enience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue.
29、 Referenced documents. In addition to MIL-DTL-38999, this document references the following: MIL-DTL-38999/26 MIL-DTL-38999/29 MIL-DTL-38999/30 MIL-DTL-38999/31 EIA-364-02 Class F is not for Navy use. Class F is inactive for use in Air Force new design. Provided by IHSNot for ResaleNo reproduction o
30、r networking permitted without license from IHS-,-,-MIL-DTL-38999/22H 10 CONCLUDING MATERIAL Custodians: Preparing activity: Army - CR DLA - CC Navy - AS Air Force 85 (Project 5935-2012-217) DLA - CC Review activities: Army - AR, MI Navy - EC, MC, OS Air Force - 19, 99 NOTE: The activities listed ab
31、ove were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1