1、 MIL-DTL-38999/40B 14 August 2009 SUPERSEDING MIL-DTL-38999/40A 11 June 2001 DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, CIRCULAR, RECEPTACLE, WALL MOUNTING FLANGE, BREECH COUPLING, REMOVABLE CRIMP CONTACTS, SERIES IV, METRIC This specification is approved for use by all Departments and Agenc
2、ies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-38999. FIGURE 1. Receptacle, classes C, F, K, P, R, S, T, W, X and Z. AMSC N/A FSC 5935 mm Inches .2 .008 .4 .016 .9 .035 METRIC Provided by IHSNot for
3、ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-38999/40B 2 Shell size Shell size code P DIA R BSC S T DIA V W Z max 11 B 3.5 (.138) 3.1 (.122) 10.31 (.406) 26.7 (1.051) 25.6 (1.008) 20.15 (.793) 19.76 (.778) 20.8 (.819) 19.2 (.756) 2.6 (.102) 2.1 (.083) 32.0 (1.26
4、0) 13 C 11.51 (.453) 29.1 (1.146) 28.0 (1.102) 23.35 (.919) 22.96 (.904) 15 D 12.31 (.485) 31.5 (1.240) 30.4 (1.197) 26.52 (1.044) 26.13 (1.029) 17 E 13.49 (.531) 33.9 (1.335) 32.8 (1.291) 29.72 (1.170) 29.33 (1.155) 19 F 14.68 (.578) 37.1 (1.461) 36.0 (1.417) 32.87 (1.294) 32.48 (1.279) 21 G 15.88
5、(.625) 40.2 (1.583) 39.1 (1.539) 36.05 (1.419) 35.66 (1.404) 3.4 (.134) 2.9 (.114) 23 H 4.0 (.157) 3.6 (.142) 17.46 (.687) 43.4 (1.709) 42.3 (1.665) 39.22 (1.544) 38.83 (1.529) 25 J 19.05 (.750) 46.6 (1.835) 45.5 (1.791) 42.40 (1.669) 42.01 (1.654) NOTES: 1. Dimensions are in millimeters. 2. Inch-po
6、und equivalent are given for information only. FIGURE 1. Receptacle, classes C, F, K, P, R, S, T, W , X and Z Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-38999/40B 3 REQUIREMENTS: Dimensions and configurations: See figure 1. In
7、terface dimensions shall conform to MIL-DTL-38999. This connector mates with MIL-DTL-38999/46 and /47. Main key color: Blue. For insert arrangements: See MIL-STD-1560. Class K is not for Air Force use. Part or Identifying Number (PIN) example: D38999/ 40 F A 35 P N DoD prefix Specification sheet no.
8、 Class Shell size code Insert arrangement Contact style Polarizing position: N is required for normal position Changes from previous issue. Marginal notations are not used in this revision to identify changes with respect to the previous issue due to the extent of the changes. Referenced documents.
9、In addition to MIL-DTL-38999, this document references the following: MIL-DTL-38999/46 MIL-DTL-38999/47 MIL-STD-1560 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-38999/40B 4 CONCLUDING MATERIAL Custodians: Preparing activity: Army CR DLA -
10、 CC Navy - AS Air Force - 85 DLA CC (Project 5935-2009-149) Review activities: Army - AR, MI Navy - EC, MC Air Force - 19, 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-