1、 MIL-DTL-49285/4A INCH-POUND15 May 2009 SUPERSEDING MIL-C-49285/4 19 October 1989 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, SIX INDIVIDUALLY SHIELDED PAIRS OF 22 (7 X 30) AWG Inactive for new design after 16 June 1997.This specification is approved for use by all Departments and
2、 Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL-49285. FIGURE 1. Cable illustration. AMSC N/A FSC 6145 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from I
3、HS-,-,-MIL-DTL-49285/4A Engineering information: See table I. Note: Not for aerospace use. TABLE I. Description, electrical. Electrical characteristics Requirements Nominal capacitance between conductors Nominal capacitance between the conductor and the shield with one conductor tied to the shield C
4、ontinuous working voltage Nominal capacitance between adjacent shields Continuous working voltage between adjacent shields Shield dc resistance 30 pF/ft (picofarads/foot) 55 pF/ft 300 V rms maximum between conductors 150 pF/ft 50 volts maximum 14 ohms/1,000 feet maximum TABLE II. Description, physic
5、al. Components Construction details Number of pairs Conductor type and wire size Conductor stranding Conductor insulation Conductor insulation thickness Drain wire type and size Drain wire stranding Jacket material Jacket thickness Finished cable diameter Cable style (UL) Tensile strength (jacket) E
6、longation (jacket) Overall cabling lay length Six individually shielded Stranded tinned copper 22 AWG 7 X 30 AWG Polypropylene 0.010 inch nominal thickness Stranded tinned copper 22 AWG 16 X 34 AWG Polyvinyl chloride 0.033 inch 0.420 inch maximum outside diameter 2919 2,000 pounds per square inch mi
7、nimum 150 percent minimum 1.3 twists per foot 10 percent Cabled pair orientation: The position of the red and green pair shield shall determine the rotation direction for pair location (see figure 1). 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
8、MIL-DTL-49285/4A TABLE III. Shield color code. Pair numbers Shield color 1stpair 2ndpair 3rdpair 4thpair 5thpair 6thpair Red Green Blue 1 Blue 2 Blue 3 Blue 4 REQUIREMENTS: Design and construction: See tables II and III. Shield location and orientation. The polyester aluminum shield is to be located
9、 on the outer circumference of the pair, with the aluminum foil side outward. Insulation on the interior of the shield is to be complete with no aluminum available for contact. Drain wire location. The drain wire is to be spirally located between the noise reducing tape and the aluminum foil shield,
10、 and is to be in continuous contact with the aluminum surface of the foil shield and the noise reducing tape throughout the cable. Cable temperature rating. The cable temperature rating shall be -20C to +80C. Flammability. The cable shall pass UL 2556 flame test requirements. Shield integrity test.*
11、 Frequency Response * 100 kHz 115 dB below reference 500 kHz 107 dB below reference 1 MHz 101 dB below reference 5 MHz 87 dB below reference 10 MHz 81 dB below reference 15 MHz 77 dB below reference 20 MHz 73 dB below reference 25 MHz 69 dB below reference 30 MHz 65 dB below reference 100 MHz 45 dB
12、below reference * Any two readings may deviate to a value of 0.9 times the stated limits. * All values are a minimum numerical value. Fixture resonance will occur between 40 and 70 MHz. 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-DTL-49285/4
13、A 4Crosstalk test limits. All values are minimums. Frequency (kHz) Near end crosstalk (dB) Far end crosstalk (dB) 40 57 57 70 54 53 100 52 51 1,000 53 51 Insulation resistance between shields. 100 megohms/1,000 feet minimum. Durometer hardness. The cable jacket shall have a “Shore A” hardness of 82
14、5. Part or Identifying Number (PIN). The PIN shall be M49285/04. Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability what
15、soever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Referenced documents. In addition to MIL-DTL-49285, this
16、 document references the following: UL 2556. CONCLUDING MATERIAL Custodians: Preparing activity: Army CR DLA - CC Navy SH Air Force 85 DLA - CC Review activity: Army MI (Project 6145-2008-153) Air Force - 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change. You should verify the currency of the information above using the ASSIST Online database at http:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1