1、 DEPARTMENT OF DEFENSE HANDBOOK LIST OF STANDARD MICROCIRCUIT DRAWINGS This handbook is for guidance only. Do not cite this document as a requirement. AMSC N/A FSC 5962 NOT MEASUREMENT SENSITIVE MIL-HDBK-103AN 12 SEPTEMBER 2013 SUPERSEDING MIL-HDBK-103AM 7 MARCH 2013 Provided by IHSNot for ResaleNo
2、reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-103AN ii FOREWORD 1. This handbook is approved for use by all Departments and Agencies of the Department of Defense. 2. This handbook is for guidance only. This handbook cannot be cited as a requirement. If it is, the contrac
3、tor does not have to comply. 3. The proliferation of industry prepared drawings for the same part used in a variety of military applications has become an ever increasing item of expense to the DoD. Numerous situations have arisen where one military acquisition document would be more appropriate and
4、 cost effective than the multiplicity of contractor prepared drawings. Standard Microcircuit Drawings (SMDs) are being prepared to eliminate the need for the multitude of contractor prepared drawings for the same device when the minimum requirements of SMDs are sufficient to meet the requirements of
5、 the application on an interim or permanent basis. 4. Comments, suggestions, or questions on this document should be addressed to: Commander, DLA Land and Maritime, ATTN: VAS, 3990 East Broad St., Columbus, OH 43218-3990, or emailed to lineardla.mil. Since contact information can change, you may wan
6、t to verify the currency of this address information using the ASSIST online database at https:/assist.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-103AN iii CONTENTS PARAGRAPH PAGE 1. SCOPE 1 1.1 Purpose 1 1.2 Part or identifyin
7、g number (PIN) . 1 1.2.1 Drawing number . 1 1.2.2 Device class designator 1 1.2.3 Case outline / lead finish . 1 1.2.4 Substitutability . 1 2. APPLICABLE DOCUMENTS . 2 3. DEFINITIONS 2 4. REQUIREMENTS . 2 4.1 Drawing requirements . 2 4.2 Preparation procedures . 2 4.3 Drawing effectivity and duratio
8、n . 2 4.4 Approved sources of supply . 2 4.5 Radiation hardness assurance (RHA) levels 2 4.6 Electrostatic discharge sensitivity (ESD) listing 2 5. CONFIGURATION MANAGEMENT . 3 5.1 Configuration management of SMDs . 3 5.2 Record of users 3 6. DISTRIBUTION and REQUESTS 4 6.1 Distribution . 4 6.1.1 Au
9、tomatic distribution . 4 6.1.2 Electronic distribution 4 6.2 Requests . 4 7. NOTES 4 7.1 Intended use . 4 7.2 Subject item (key word) listing 4 TABLE 1 Noun code descriptions . 5 SECTION 1 Microcircuits 12 Part I Listed by SMD PIN 12 Part II Listed by generic PIN 716 Part III Listed approved sources
10、 934 Concluding material 938 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-103AN 1 1. SCOPE 1.1 Purpose. The Standard Microcircuit Drawing Program (SMDP) is directly under the auspices of the DoD Parts Management Program (PMP). The PMP is
11、implemented by MIL-HDBK-512, “Parts Management.“ The PMP will be the avenue for screening candidate parts for the SMDP by the DLA Land and Maritime Military Parts Control Advisory Group (MPCAG). 1.2 Part or Identifying number (PIN). The PINs listed in section 1, part I, are composed of the elements
12、shown in the following example (see 1.2.2 for one part - one part number differentiation): One part - one part number PIN 5962-90123 01 M X A Drawing number Device Device Case Lead (1.2.1) Type Class Outline Finish Designator (1.2.3) (1.2.3) (1.2.2) Non - one part - one part number PIN 86030 01 X A
13、or 5962-88668 Drawing number Device type Case outline Lead finish (1.2.3) (1.2.3) 1.2.1 Drawing number. One part - one part number SMDs for device classes Q, V, H, and K may cover custom device products which are generally used to specify application specific integrated circuits (both monolithic and
14、 hybrid). To differentiate between one part - one part number SMDs that cover standard product from custom product a single alpha character will be placed in the unique 3 digit portion of the SMD drawing number as in the following example: 5962-90A23. This will be the only change to the SMD PIN for
15、custom products. 1.2.2 Device class designator. One part - one part number SMDs (fully implemented after SMD 5962-90659) contain device requirements for all three of the major military microcircuit requirements documents. By establishing a one part number system covering all three documents, the OEM
16、 can acquire to the highest level available for a given generic device to meet system needs without modifying the original contract parts selection criteria. Manufacturing Document Military documentation format Example PIN source listing listing New MIL-PRF-38535 Standard 5962-XXXXXZZ(Q,V,T or N)YY
17、QML-38535 MIL-HDBK-103 Microcircuit Drawings New MIL-PRF-38534 Standard 5962-XXXXXZZ(H,K,D,G or E)YY QML-38534 MIL-HDBK-103 Microcircuit Drawings New 1.2.1 of MIL-STD-883 Standard 5962-XXXXXZZ(M)YY MIL-HDBK-103 MIL-HDBK-103 Microcircuit Drawings, based on Appendix A of MIL-PRF-38535 1.2.3 Case outli
18、ne/lead finish. Case outline and lead finish are as described in each SMD. The lead finish indicated in the section 1 Part I listing is the most readily available from the manufacturer listed for the part. The manufacturer is authorized to supply other lead finishes than what is listed provided that
19、 further testing/qualification is performed by the manufacturer on the other lead finish(es). The user needs to contact the manufacturer to determine the availability of other lead finishes not listed herein. 1.2.4 Substitutability. Device-class-Q devices will replace device-class-M devices. This ha
20、ndbook is for guidance only and cannot be cited as a requirement. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-103AN 2 2. APPLICABLE DOCUMENTS This section is not applicable to the handbook. 3. DEFINITIONS This section is not applicable t
21、o the handbook. 4. REQUIREMENTS 4.1 Drawing requirements. SMDs will be prepared in accordance with ASME Y14.100 and DOD directives. 4.2 Preparation procedures. The procedures for the generation of an SMD are provided in MIL-HDBK-780. 4.3 Drawing effectivity and duration. SMDs and device class M one
22、part - one part number SMDs which have become inactive for new design are reflected in section 1, part 1 of the appendix of this document with an “I“ in the status column. 4.4 Approved sources of supply. The approved sources of supply list in this handbook supersedes the approved sources formerly li
23、sted in each individual SMD/DLA Land and Maritime Drawing. This handbook is the official list of approved sources of supply for non-one part - one part number SMD PINs and for device class M one part - one part number SMD PINs. Device classes B, S, Q, V, T, N (monolithic) and H, K, D, G, E (hybrid)
24、one part - one part number SMD PINs are listed for the convenience of the users. Official listing for B, S, Q, V, T, N, H, K, D, G, and E levels are available in the applicable QML. Manufacturers should notify DLA Land and Maritime-VA in writing if they no longer wish to be listed as an approved sou
25、rce of supply for any device listed herein. This letter will be used by DSCC to remove the manufacturer from MIL-HDBK-103 for those devices that the manufacturer specifies that he will no longer supply. 4.5 Radiation hardness assurance (RHA) levels. SMD devices which meet the RHA requirements of MIL
26、-PRF-38535 or MIL-PRF-38534 will be marked with the appropriate RHA designator M, D, P, L, R, F, G, or H replacing the dash (-) in the PIN as indicated in the following example: 5962(M, D, P, L, R, F, G, or H)8999901EA Only the highest RHA level for which the device is qualified will be listed in Se
27、ction 1, Part I of the appendix of this document; however, at the request of the customer, the manufacturer is authorized to supply any lower RHA level device. At the request of the customer, the non-RHA PIN designated with a dash (-) may be supplied at the option of the manufacturer. The manufactur
28、er may also opt to submit a certificate of compliance to have the non-RHA PIN listed in addition to the RHA PIN in Section 1, Part I of the appendix of this document. 4.6 Electrostatic discharge sensitivity (ESD) listing. ESD classification levels, as required by MIL-PRF-38534 or MIL-PRF-38535, will
29、 be listed in the status column of section 1, part 1, of the appendix. Manufacturers are required to send these classification levels to DLA Land and Maritime-VA for all Standard Microcircuit Drawings for which they are an approved source. The ESD listing in section 1, part 1 of the appendix will be
30、 in accordance with the following: STATUS INTERPRETATION Blank Data not submitted 0 Class 0; 250 V 1 Class 1; 0 1999 V 1A Class 1A; 250 V 499 V 1B Class 1B; 500 V 999 V 1C Class 1C; 1,000 V 1999 V 2 Class 2; 2000 V 3999 V 3 Class 3; 4000 V 3A Class 3A; 4000 V 7999 V 3B Class 3B; 8000 V Provided by I
31、HSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-103AN 3 5. CONFIGURATION MANAGEMENT 5.1 Configuration management of SMDs. All proposed changes to existing SMDs will be coordinated with the military activities and industry users of record for the individu
32、al documents. This coordination will be accomplished using DD Form 1693, Engineering Change Proposal (Short Form). 5.2 Record of users. Industrial users should inform DLA Land and Maritime when a system application requires use of the SMD. When notified, DLA Land and Maritime will maintain a record
33、of users and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices (FSC 5962) should contact DLA Land and Maritime-VAC, telephone (614) 692-8108. Provided by IHSNot for ResaleNo reproduction or networking permitted wit
34、hout license from IHS-,-,-MIL-HDBK-103AN 4 6. DISTRIBUTION AND REQUESTS 6.1 Distribution. Requests for individual drawings and revisions to existing drawings may be addressed to: DLA Land and Maritime ATTN: VAC 3990 E. Broad Street Columbus, OH 43218-3990 Autovon 850-0547 Commercial (614) 692-0547 6
35、.1.1 Automatic distribution. To be added to a mailing list for automatic distribution of new drawings and revisions to existing drawings requests may be addressed to: DLA Land and Maritime ATTN: VAS 3990 E. Broad Street Columbus, OH 43218-3990 Autovon 850-8478 Commercial (614) 692-8478 6.1.2 Electro
36、nic distribution. Electronic copies of Standard Microcircuit Drawings are available on the World Wide Web at http:/www.landandmaritime.dla.mil/Programs/MilSpec. 6.2 Requests. Requests for copies may be available online at http:/quicksearch.dla.mil or https:/assist.dla.mil or from the Standardization
37、 Document Order Desk, 700 Robbins Avenue, Building 4D,Philadelphia, PA 19111-5094 7. NOTES 7.1 Intended use. This list has been prepared for use by or for the Government in the acquisition of products covered by SMDs. Listing of a product is not intended to and does not connote endorsement of the pr
38、oduct by the Department of Defense. This list is subject to change without notice; revision or amendment of this list will be issued as necessary. This listing supersedes the approved source of supply listing in the individual Standard Microcircuit Drawings, however the listing of a product does not
39、 release the supplier from compliance with the SMD requirements. 7.2 Subject item (key word) listing. Part or identifying number (PIN) Drawing number Device class designator Drawing requirements Preparation procedures Drawing effectivity and duration Approved sources of supply Radiation hardness ass
40、urance (RHA) levels Electrostatic discharge sensitivity (ESD) listing Configuration management of SMDs Noun code descriptions 7.3 Changes from previous issue. Marginal notations are not used in this revision to identify Changes with respect to the previous issue due to the extent of the changes. Pro
41、vided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-HDBK-103AN TABLE I. Noun Code Descriptions. Noun Description 5 100 MICROCIRCUIT, POSITIVE-NAND GATES, QUAD 2-INPUT 101 MICROCIRCUIT, POSITIVE-NAND GATES, QUAD 2-INPUT, OPEN COLLECTOR OUTPUTS 102 MICROC
42、IRCUIT, POSITIVE-NAND GATES, TRIPLE 3-INPUT 103 MICROCIRCUIT, POSITIVE-NAND GATES, TRIPLE 3-INPUT, OPEN COLLECTOR OUTPUTS 104 MICROCIRCUIT, POSITIVE-NAND GATES, DUAL 4-INPUT 105 MICROCIRCUIT, POSITIVE-NAND GATES, DUAL 4-INPUT, OPEN COLLECTOR OUTPUTS 106 MICROCIRCUIT, POSITIVE-NAND GATES, SINGLE 8-IN
43、PUT 107 MICROCIRCUIT, POSITIVE-NAND GATES, SINGLE 8-INPUT, EXPANDABLE 108 MICROCIRCUIT, POSITIVE-NAND GATES (GREATER THAN 8-INPUT) 109 MICROCIRCUIT, POSITIVE-NAND GATES, NOT OTHERWISE CLASSIFIED 110 MICROCIRCUIT, POSITIVE-AND GATES, QUAD 2-INPUT 111 MICROCIRCUIT, POSITIVE-AND GATES, QUAD 2-INPUT, OP
44、EN COLLECTOR OUTPUTS 112 MICROCIRCUIT, POSITIVE-AND GATES, TRIPLE 3-INPUT 113 MICROCIRCUIT, POSITIVE-AND GATES, TRIPLE 3-INPUT, OPEN COLLECTOR OUTPUTS 114 MICROCIRCUIT, POSITIVE-AND GATES, DUAL 4-INPUT 115 MICROCIRCUIT, POSITIVE-AND GATES, DUAL 4-INPUT, OPEN COLLECTOR OUTPUTS 119 MICROCIRCUIT, POSIT
45、IVE-AND GATES, N.O.C. 120 MICROCIRCUIT, POSITIVE-NOR GATES, QUAD 2-INPUT 121 MICROCIRCUIT, POSITIVE-NOR GATES, QUAD 2-INPUT, OPEN COLLECTOR OUTPUTS 122 MICROCIRCUIT, POSITIVE-NOR GATES, TRIPLE 3-INPUT 123 MICROCIRCUIT, POSITIVE-NOR GATES, DUAL 4-INPUT 124 MICROCIRCUIT, POSITIVE-NOR GATES, N.O.C. 125
46、 MICROCIRCUIT, POSITIVE-OR GATES 130 MICROCIRCUIT, AND-OR-INVERT GATES, DUAL 2-WIDE 131 MICROCIRCUIT, AND-OR-INVERT GATES, 4-WIDE 132 MICROCIRCUIT, AND-OR-INVERT GATES, 2-WIDE 133 MICROCIRCUIT, AND-OR-INVERT GATES, DUAL 2-WIDE, EXPANDABLE 134 MICROCIRCUIT, AND-OR-INVERT GATES, 4-WIDE, EXPANDABLE 135
47、 MICROCIRCUIT, AND-OR-INVERT GATES, 2-WIDE, EXPANDABLE 139 MICROCIRCUIT, AND-OR-INVERT GATES, N.O.C. 140 MICROCIRCUIT, EXCLUSIVE-OR GATES 141 MICROCIRCUIT, EXCLUSIVE-NOR GATES 142 MICROCIRCUIT, OR-AND GATES 143 MICROCIRCUIT, HEX INVERTERS 144 MICROCIRCUIT, HEX INVERTERS, OPEN COLLECTOR 145 MICROCIRCUIT, EXPANDERS 149 MICROCIRCUIT, LOGIC GATES, N.O.C. 150 MICROCIRCUIT, FLIP FLOPS, AND-GATED, SINGLE J-K FLIP FLOP 151 MICROCIRCUIT, FLIP FLOPS, AND-OR-GATED, SINGLE J-K FLIP FLOP 152 MICROCIRCUIT, FLIP FLOPS, DUAL J-K (2-COMPLETELY INDEPENDENT CIRCUITS) 153 MICROCIRCUIT,
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1