1、AMSC N/A FSC 5920 MIL-PRF-15160/65F 2 November 2011 SUPERSEDING MIL-PRF-15160/65E 17 August 2006 PERFORMANCE SPECIFICATION SHEET FUSES, INSTRUMENT, POWER, AND TELEPHONE (NONINDICATING), STYLE F65 This specification is approved for use by all Departments and Agencies of the Department of Defense. The
2、 requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-15160. FIGURE 1. Style F65, characteristic C. INCH-POUND Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/65F 2 Ltr Inches mm
3、Min Max Min Max A 8.531 8.719 216.69 221.36 B 4.625 - 117.48 - C 1.875 - 47.63 - D 1.188 - 30.18 - E 1.590 1.660 40.39 42.16 F - 2.406 - 61.11 G .247 .253 6.27 6.43 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. The length of the cylindrical body
4、 may be less than the indicated value if other acceptable interference means (pins through blades, collars, and so forth) are provided to prevent mounting the fuse in a fuseholder that will accommodate a fuse rated in the next lower bracket of current ratings. FIGURE 1. Style F65, characteristic C -
5、 Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/65F 3 REQUIREMENTS: Interface and physical dimensions: See figure 1. Case: Glass melamine. Knifeblade: Brass, copper, bronze, or copper alloy. Finish: Nickel or bright alloy pl
6、ate, silver plated when specified. Terminal strength: Method 211 of MIL-STD-202, test condition E, 5 pound-inch torque. Electrical: Current rating: See table I. Current carrying capacity: 110 percent of rated current. Voltage rating: See table I. Characteristic: Characteristic C only. Overload inter
7、rupt: Within 2 hour at 135 percent of rated current; and within 10 minutes at 200 percent. Short circuit interrupt: 200,000 A at 500 V ac (symmetrical), 150,000 A at 500 V dc. Shock: Method 207 of MIL-STD-202, HI shock. Vibration: Method 204 of MIL-STD-202, test condition A (except 5g, 500 Hz). Part
8、 or Identifying Number (PIN): The PIN shall be constructed from table I (e.g., F65C500V225A). TABLE I. Part or Identifying Number. 1/ 1/ For silver plated terminals, the designator “S“ is added after the current rating. Temperature rise: Temperature rise shall be not greater than the values shown in
9、 table II. TABLE II. Allowable temperature rise. Style Characteristic Voltage Current F65 F65 F65 F65 F65 C C C C C 500V 500V 500V 500V 500V 225A 250A 300A 350A 400A Casing or body Terminal Thermometer Thermocouple Thermometer Thermocouple 50C 90C 60C 90C Provided by IHSNot for ResaleNo reproduction
10、 or networking permitted without license from IHS-,-,-MIL-PRF-15160/65F 4 VERIFICATION: Qualification inspections: The number of qualification samples required shall be: a. 24 samples maximum current rating of each voltage and design. b. 24 samples minimum current rating of each voltage and design.
11、NOTE: If labels are used, five additional samples of any rating are required. Sample size: The number of group III samples shall be twelve samples each of the maximum and minimum current ratings. The samples shall be divided as shown in table III. TABLE III. Short circuit test. 1/ A 600 volt ac test
12、 voltage may be used. Group C inspection: Group C inspection shall be performed on short circuit current ratings of 5,000 A at 500 V ac; 200,000 A at 500 V ac; and 5,000 A at 500 V dc. The 150,000 A at 500V dc short circuit current test is not required to be performed for group C testing. INSPECTION
13、 ROUTINE: AC short circuit test: AC short circuit tests shall be performed at the currents shown in table II at not less than 500 volts, single phase, and not greater than 20 percent power factor, lagging. The current shall be applied within plus or minus 10 degrees of the zero point of the voltage
14、wave. DC short circuit test: DC short circuit tests shall be performed at the currents shown in table II at not Less than 500 volts. The rate of rise shall be between 25,000,000 and 30,000,000 amperes per second. Cross-reference: For applicable cross-reference see table IV. The existing stocks of su
15、perseded items may be used. When exhausted, the superseding parts shall be used. TABLE IV. Cross-reference. Number of samples Short circuit current Test voltage 3 3 3 3 5,000 A 200,000 A 5,000 A 150,000 A 500 V ac 1/ 500 V ac 1/ 500 V dc 500 V dc Superseding Superseded numbers for CAGE number 81349
16、96906 F65C500V225A F65C500V250A F65C500V300A F65C500V350A F65C500V400A F65H225R0C F65H250R0C F65H300R0C F65H350R0C F65H400R0C MS15254-1 MS15254-2 MS15254-3 MS15254-4 MS15254-5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-15160/65F 5 Refere
17、nced documents. In addition to MIL-PRF-15160, this document references the following: MIL-STD-202 The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability
18、whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Custodians: Preparing activity: Army - CR DLA - CC N
19、avy - SH Air Force - 85 (Project 5920-2011-063) DLA - CC Review activities: Army - AT, CR4, MI Navy - AS, CG, MC, OS Air Force - 19, 99 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-