1、AMSC N/A FSC 5910 MIL-PRF-20/35K 21 April 2011 SUPERSEDING MIL-PRF-20/35J 21 June 2001 PERFORMANCE SPECIFICATION SHEET CAPACITORS, FIXED, CERAMIC DIELECTRIC (TEMPERATURE COMPENSATING), ESTABLISHED AND NON-ESTABLISHED RELIABILITY, STYLES CCR05, CC05, CCR09, AND CC09 This specification is approved for
2、 use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the capacitors described herein shall consist of this specification sheet and MIL-PRF-20. FIGURE 1. Styles CCR05, CC05, CCR09, and CC09 capacitors. INCH-POUND Styles CC05 and CC09 are inactive for new d
3、esign after 19 September 1983. Use CCR05 and CCR09. Inches mm .010 0.25 .015 0.38 .030 0.75 .045 1.15 .090 2.29 .100 2.54 .190 4.83 .200 5.08 1.250 31.75 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-20/35K 2 NOTES: 1. Dimensions are in inc
4、hes. 2. Metric equivalents are given for information only. 3. Lead diameter shall be .023 (0.58 mm) to .029 (0.74 mm). 4. Optional standoffs for style CCR05 shall be of triangular shape so that the standoffs will provide line contact with surface upon which the capacitor is mounted. The shape of the
5、 triangle is optional. 5. Thickness of standoffs shall be .075 (1.90 mm) to the body thickness. 6. Lead length may be a minimum of .625 (15.88 mm) for use in tape and reel automatic insertion equipment, when specified. 7. At the option of the user, the standoff configuration may be furnished as a re
6、placement for the nonstandoff configuration of the same style. FIGURE 1. Styles CCR05, CC05, CCR09, and CC09 capacitors - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-20/35K 3 REQUIREMENTS: Dimensions and configuration: See figu
7、re 1. Lead type: Radial. Case type: Molded. DC rated voltage: See table I. Operating temperature range: -55C to +125C. Characteristic: See table I. Failure rate level (CCR05 and CCR09 only): M (1.0 percent), P (0.1 percent), R (.01 percent) or S (.001 percent). Thermal shock and voltage conditioning
8、 (CCR05 and CCR09 only): In accordance with MIL-PRF-20. Capacitance: Within tolerance specified (see table I). Dissipation factor: In accordance with MIL-PRF-20. Dielectric withstanding voltage: In accordance with MIL-PRF-20. Body insulation: Test II. Solderability: The leads shall be solderable up
9、to .020 inch (0.51 mm) from the body egress. Resistance to soldering heat: In accordance with MIL-PRF-20. TABLE I. Capacitor characteristics. PIN 1/ 2/ 3/ Rated voltage (volts, dc) Nominal capacitance (pF) Capacitance tolerance PIN 1/ 2/ Rated voltage (volts, dc) Nominal capacitance (pF) Capacitance
10、 tolerance CC-0-CX1R0- CC-0-CX1R1- CC-0-CX1R2- CC-0-CX1R3- CC-0-CX1R5- CC-0-CX1R6- CC-0-CX1R8- CC-0-CX2R0- CC-0-CK2R2- CC-0-CK2R4- CC-0-CK2R7- CC-0-CK3R0- CC-0-CK3R3- CC-0-CK3R6- CC-0-CK3R9- 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 1.0 1.1 1.2 1.3 1.5 1.6 1.8 2.0 2.2 2.4 2.7 3.0 3
11、.3 3.6 3.9 BC BC BC BC BC BC BC BC BC BC BCD BCD BCD BCD BCD CC-0-CJ4R3- CC-0-CJ4R7- CC-0-CJ5R1- CC-0-CJ5R6- CC-0-CJ6R2- CC-0-CJ6R8- CC-0-CJ7R5- CC-0-CH8R2- CC-0-CH9R1- CC-0-CH100- CC-0-CH110- CC-0-CH120- CC-0-CH130- CC-0-CH150- CC-0-CH160- 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200
12、 4.3 4.7 5.1 5.6 6.2 6.8 7.5 8.2 9.1 10 11 12 13 15 16 BCD BCD BCD BCD BCD BCD BCD BCD BCD FG FGJ FGJ FGJ FGJ FGJ See footnotes at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-20/35K 4 TABLE I. Capacitor characteristics - Con
13、tinued. PIN 1/ 2/ Rated voltage (volts, dc) Nominal capacitance (pF) Capacitance tolerance PIN 1/ 2/ Rated voltage (volts, dc) Nominal capacitance (pF) Capacitance tolerance CC-0-CH180- CC-0-CG200- CC-0-CG220- CC-0-CG240- CC-0-CG270- CC-0-CG300- CC-0-CG330- CC-0-CG360- CC-0-CG390- CC-0-CG430- CC-0-C
14、G470- CC-0-CG510- CC-0-CG560- CC-0-CG620- CC-0-CG680- CC-0-CG750- CC-0-CG820- CC-0-CG910- CC-0-CG101- CC-0-CG111- CC-0-CG121- CC-0-CG131- CC-0-CG151- CC-0-CG161- CC-0-CG181- CC-0-CG201- CC-0-CG221- CC-0-CG241- 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 20
15、0 200 200 200 200 200 18 20 22 24 27 30 33 36 39 43 47 51 56 62 68 75 82 91 100 110 120 130 150 160 180 200 220 240 FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ CC-0-CG271- CC-0-CG301- CC-0-CG331- CC-0-CG361- CC-0-CG391- CC-0-CG431-
16、CC-0-CG471- CC-0-CG511- CC-0-CG561- CC-0-CG621- CC-0-CG681- CC-0-CG751- CC-0-CG821- CC-0-CG911- CC-0-CG102- CC-0-CG112- CC-0-CG122- CC-0-CG132- CC-0-CG152- CC-0-CG162- CC-0-CG182- CC-0-CG202- CC-0-CG222- CC-0-CG242- CC-0-CG272- CC-0-CG302- CC-0-CG332- 200 200 200 100 100 100 100 100 100 100 100 100
17、100 100 100 100 100 100 100 100 100 50 50 50 50 50 50 270 300 330 360 390 430 470 510 560 620 680 750 820 910 1000 1100 1200 1300 1500 1600 1800 2000 2200 2400 2700 3000 3300 FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ FGJ 1/ Complete PIN w
18、ill include the following: 1st dash - Symbol “R” (for styles CCR05 and CCR09) or dash will be deleted (for styles CC05 and CC09). 2nd dash - Applicable style number (5 for .200 .015 lead spacing and 9 for .100 0.015 lead spacing). 3rd dash - Applicable capacitance tolerance symbol. 4th dash - Applic
19、able failure rate level symbol (CCR05 and CCR09 only) or dash will be deleted (for styles CC05 and CC09). 5th dash - Symbol “V” (for standoff mounting configuration) or dash will be deleted for no standoff. 2/ With respect to characteristics in previous revisions of this specification sheet: For cap
20、acitance values of 2 pF or less, characteristic CX is interchangeable with characteristic CH; for capacitance values of 2.2 pF through 3.9 pF, characteristic CK is interchangeable with characteristic CH; for capacitance values of 4.3 pF through 7.5 pF, characteristic CJ is interchangeable with chara
21、cteristic CH; and for capacitance values of 11 pF through 18 pF, characteristic CH is interchangeable with characteristic CG. These parts shall be stocked under the same applicable NSNs. 3/ Temperature coefficient is not practically measurable for characteristic CX capacitors. Provided by IHSNot for
22、 ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-20/35K 5 Workmanship: For style CCR05 with standoff, exposed copper or bare leads shall be permitted to a maximum of .020 inch (0.51 mm) from the body egress. For style CCR05 without standoff, workmanship shall be in
23、 accordance with MIL-PRF-20. Temperature coefficient and capacitance drift: In accordance with MIL-PRF-20. For capacitors with values of 18 pF or less, the temperature coefficient tolerance shall be determined in accordance with table II. TABLE II. Temperature coefficient tolerances. Permissible cap
24、acitance change from capacitance at +25C in ppm/C Temperature Characteristic CX CK CJ CH CG +125C 1/ 250 ppm/C 120 ppm/C 60 ppm/C 30 ppm/C -55C 2/ 1/ +246.25 -326.25 +116.25 -166.25 +55.00 -91.25 +27.50 -53.75 1/ Not practically measurable. 2/ The ppm/C values for -55C were calculated by dividing pp
25、m by negative 80C. Life: In accordance with MIL-PRF-20, operating condition 2. Part or Identifying Number (PIN): In accordance with MIL-PRF-20 and table I. Marking: Method I of MIL-STD-1285. At the option of the manufacturer, the marking may be placed on one side of the capacitor, or the marking may
26、 be placed on two lines as long as it is in the same order as shown in the following examples: ER NON-ER FRONT WITHOUT STANDOFFS BACK FRONT BACK DATE CODE DATE CODE CAGE CAGE PIN LOT CODE PIN LOT CODE & “J” BRAND FRONT WITH STANDOFFS PIN CCR0 5CH1 00FM 1120 AJ1 2345 CC05 CH 100F 1120 A 1 2345 CCR0 5
27、CH1 00FMV Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-20/35K 6 Referenced documents. In addition to MIL-PRF-20, this specification sheet references the following document: MIL-STD-1285 Changes from previous issue: The margins of this spec
28、ification sheet are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requiremen
29、ts of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. Custodians: Preparing activity: Army - CR DLA - CC Navy - EC Air Force -85 (Project 5910-2011-016) DLA - CC Review activities: Navy - AS, MC, OS, SH Air Force 99 NOTE:
30、The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-