1、AMSC N/A FSC 5930 INCH POUND MIL-PRF-22885/113A 6 May 2010 MIL-PRF-22885/113 6 May 2008 PERFORMANCE SPECIFICATION SHEET SWITCHES, PUSHBUTTON, ILLUMINATED, 1.17 BY .96, LIGHT EMITTING DIODE (LED), SUNLIGHT READABLE, VOLTAGE DIMMABLE, NIGHT VISION GOGGLE COMPATIBLE, EMC COMPLIANT, COMMON TERMINATION S
2、YSTEM (CTS), SPDT, DPDT, 4PDT, LOGIC LEVEL TO 7.5 AMPERES, DRIPPROOF, WATERTIGHT, SPLASHPROOF, HIGH IMPACT SHOCK RESISTANT This specification sheet is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall cons
3、ist of this specification sheet and MIL-PRF-22885. NOTES: 1. Dimensions are in inches. Metric equivalents are given for general information only. 2. Unless otherwise specified, tolerances are .010 for three place decimals and .03 for two place decimals. 3. The switch shall accommodate mounting to pa
4、nels from .032 to .187 thick. 4. A mounting spacer is supplied with each switch unit for SAE-AS7788 panel requirements and places the mounting flange flush with the top of a .235 thick edge lighted panel when used in front of the panel. Otherwise, the spacer is used behind the panel. 5. Pushbutton c
5、ap shall be designed to prevent incorrect insertion into switch housing. 6. Pushbutton cap shall be held captive to switch body by retaining element to prevent accidental interchange. 7. Exact shape of switch is optional provided dimensions specified are not exceeded. 8. Terminals and basic switch i
6、dentification shall be permanently marked as shown on figure 12. FIGURE 1. Switch - type I, 2 pole (enclosure design 1, unsealed with solder terminals). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-22885/113A 2 NOTES: 1. Dimensions are in
7、inches. Metric equivalents are given for general information only. 2. Unless otherwise specified, tolerances are .010 for three place decimals and .03 for two place decimals. 3. The switch shall accommodate mounting to panels from .032 to .187 thick. 4. A mounting spacer is supplied with each switch
8、 unit for SAE-AS7788 panel requirements and places the mounting flange flush with the top of a .235 thick edge lighted panel when used in front of the panel. Otherwise, the spacer is used behind the panel. 5. Pushbutton cap shall be designed to prevent incorrect insertion into switch housing. 6. Pus
9、hbutton cap shall be held captive to switch body by retaining element to prevent accidental interchange. 7. Exact shape of switch is optional provided dimensions specified are not exceeded. 8. Terminals and basic switch identification shall be permanently marked as shown on figure 12. FIGURE 2. Swit
10、ch - type II, 2 pole (enclosure design 2, 3, and 4; dripproof, watertight, and splashproof with solder terminals). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-22885/113A 3 NOTES: 1. Dimensions are in inches. Metric equivalents are given f
11、or general information only. 2. Unless otherwise specified, tolerances are .010 for three place decimals and .03 for two place decimals. 3. The switch shall accommodate mounting to panels from .032 to .187 thick. 4. A mounting spacer is supplied with each switch unit for SAE-AS7788 panel requirement
12、s and places the mounting flange flush with the top of a .235 thick edge lighted panel when used in front of the panel. Otherwise, the spacer is used behind the panel. 5. Pushbutton cap shall be designed to prevent incorrect insertion into switch housing. 6. Pushbutton cap shall be held captive to s
13、witch body by retaining element to prevent accidental interchange. 7. The Common Termination System (CTS) connector shall be designed and constructed to meet the performance requirements of this document. This item, M22885/108-18200 for 2 pole switches, shall be acquired from a source listed on QPL-
14、22885. 8. The CTS connector shall be removable from the switch housing to allow the housing to be mounted separately. The connector may be wired during harnessing operations, allowing bench testing without the need of the switch housing 9. The CTS connector shall be considered as a connector plug th
15、at may be separated from the switch housing for the convenience of installation. 10. The CTS connector shall be removable from the switch body by use of a M22885/108-T8234 CTS module extraction tool. Refer to MIL-PRF-22885/108 for details. This item shall be acquired from a source listed on QPL-2288
16、5. 11. The CTS connector shall be capable of receiving SAE-AS39029/22-192 socket contacts crimped to a 20, 22, or 24 gauge wire. 12. The CTS connector shall be capable of having the socket contacts inserted or removed using an M81969/14-10 contact insertion/removal tool. 13. Exact shape of switch is
17、 optional provided dimensions specified are not exceeded. 14. Terminals and basic switch identification shall be permanently marked as shown on figure 12. FIGURE 3. Switch - type III (enclosure design 1; unsealed with 2 pole common termination system). 1.93 MAX FROM FRONT OF PANEL Provided by IHSNot
18、 for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-22885/113A 4 Notes 1. Dimensions are in inches. Metric equivalents are given for general information only. 2. Unless otherwise specified, tolerances are .010 for three place decimals and .03 for two place decimal
19、s. 3. The switch shall accommodate mounting to panels from .032 to .187 thick. 4. A mounting spacer is supplied with each switch unit for SAE-AS7788 panel requirements and places the mounting flange flush with the top of a .235 thick edge lighted panel when used in front of the panel. Otherwise, the
20、 spacer is used behind the panel. 5. Pushbutton cap shall be designed to prevent incorrect insertion into switch housing. 6. Pushbutton cap shall be held captive to switch body by retaining element to prevent accidental interchange. 7. The Common Termination System (CTS) connector shall be designed
21、and constructed to meet the performance requirements of this document. This item, M22885/108-18200 for 2 pole switches, shall be acquired from a source listed on QPL-22885. 8. The CTS connector shall be removable from the switch housing to allow the housing to be mounted separately. The connector ma
22、y be wired during harnessing operations, allowing bench testing without the need of the switch housing 9. The CTS connector shall be considered as a connector plug that may be separated from the switch housing for the convenience of installation. 10. The CTS connector shall be removable from the swi
23、tch body by use of a M22885/108-T8234 CTS module extraction tool. Refer to MIL-PRF-22885/108 for details. This item shall be acquired from a source listed on QPL-22885. 11. The CTS connector shall be capable of receiving SAE-AS39029/22-192 socket contacts crimped to a 20, 22, or 24 gauge wire. 12. T
24、he CTS connector shall be capable of having the socket contacts inserted or removed using an M81969/14-10 contact insertion/removal tool. 13. Exact shape of switch is optional provided dimensions specified are not exceeded. 14. Terminals and basic switch identification shall be permanently marked as
25、 shown on figure 12. FIGURE 4. Switch - type IV (enclosure design 2, 3, and 4; dripproof, watertight and splashproof with 2 pole common termination system) 1.85 MAX FROM FRONT OF PANEL Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-22885/113
26、A 5 NOTES: 1. Dimensions are in inches. Metric equivalents are given for general information only. 2. Unless otherwise specified, tolerances are .010 for three place decimals and .03 for two place decimals. 3. The switch shall accommodate mounting to panels from .032 to .187 thick. 4. A mounting spa
27、cer is supplied with each switch unit for SAE-AS7788 panel requirements and places the mounting flange flush with the top of a .235 thick edgelighted panel when used in front of the panel. Otherwise, the spacer is used behind the panel. 5. Pushbutton cap shall be designed to prevent incorrect insert
28、ion into switch housing. 6. Pushbutton cap shall be held captive to switch body by retaining element to prevent accidental interchange. 7. The Common Termination System (CTS) connector shall be designed and constructed to meet the performance requirements of this document. This item, M22885/108-C824
29、0 for 4 pole switches, shall be acquired from a source listed on QPL-22885. 8. The CTS connector shall be removable from the switch housing to allow the housing to be mounted separately. The connector may be wired during harnessing operations, allowing bench testing without the need of the switch ho
30、using 9. The CTS connector shall be considered as a connector plug that may be separated from the switch housing for the convenience of installation. 10. The CTS connector shall be removable from the switch body by use of a M22885/108-T8234 CTS module extraction tool. Refer to MIL-PRF-22885/108 for
31、details. This item shall be acquired from a source listed on QPL-22885. 11. The CTS connector shall be capable of receiving SAE-AS39029/22-192 socket contacts crimped to a 20, 22, or 24 gauge wire. 12. The CTS connector shall be capable of having the socket contacts inserted or removed using an M819
32、69/14-10 contact insertion/removal tool. 13. Exact shape of switch is optional provided dimensions specified are not exceeded. 14. Terminals and basic switch identification shall be permanently marked as shown on figure 12. FIGURE 5. Switch - type V (enclosure design 1: unsealed with 4 pole common t
33、ermination system) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-22885/113A 6 NOTES: 1. Dimensions are in inches. Metric equivalents are given for general information only. 2. Unless otherwise specified, tolerances are .010 for three place
34、decimals and .03 for two place decimals. 3. The switch shall accommodate mounting to panels from .032 to .187 thick. 4. A mounting spacer is supplied with each switch unit for SAE-AS7788 panel requirements and places the mounting flange flush with the top of a .235 thick edgelighted panel when used
35、in front of the panel. Otherwise, the spacer is used behind the panel. 5. Pushbutton cap shall be designed to prevent incorrect insertion into switch housing. 6. Pushbutton cap shall be held captive to switch body by retaining element to prevent accidental interchange. 7. The Common Termination Syst
36、em (CTS) connector shall be designed and constructed to meet the performance requirements of this document. This item, M22885/108-C8240 for 4 pole switches, shall be acquired from a source listed on QPL-22885. 8. The CTS connector shall be removable from the switch housing to allow the housing to be
37、 mounted separately. The connector may be wired during harnessing operations, allowing bench testing without the need of the switch housing 9. The CTS connector shall be considered as a connector plug that may be separated from the switch housing for the convenience of installation. 10. The CTS conn
38、ector shall be removable from the switch body by use of a M22885/108-T8234 CTS module extraction tool. Refer to MIL-PRF-22885/108 for details. This item shall be acquired from a source listed on QPL-22885. 11. The CTS connector shall be capable of receiving SAE-AS39029/22-192 socket contacts crimped
39、 to a 20, 22, or 24 gauge wire. 12. The CTS connector shall be capable of having the socket contacts inserted or removed using an M81969/14-10 contact insertion/removal tool. 13. Exact shape of switch is optional provided dimensions specified are not exceeded. 14. Terminals and basic switch identifi
40、cation shall be permanently marked as shown on figure 12. FIGURE 6. Switch- type VI (enclosure design 2, 3, and 4: dripproof, watertight, and splashproof with 4 pole common termination system). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-
41、22885/113A 7 NOTES: 1. Dimensions are in inches. Metric equivalents are given for general information only. 2. Unless otherwise specified, tolerances are .010 for three place decimals and .03 for two place decimals. FIGURE 7. Switch and lighting circuit terminations, Type I and II, dimensions and ce
42、nter location. Inches mm .003 0.08 .010 0.25 .020 0.51 .030 0.76 .04 1.0 .06 1.5 .069 1.75 .106 2.69 .125 3.18 .150 3.81 .213 5.41 .237 6.02 .500 12.70 .698 17.73 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-22885/113A 8 NOTES: 1. Dimensio
43、ns are in inches. Metric equivalents are given for general information only. 2. Unless otherwise specified, tolerances are .010 for three place decimals and .03 for two place decimals. FIGURE 8. Switch and lighting circuit terminations, Common Termination System (CTS), interface. Provided by IHSNot
44、for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-22885/113A 9 FIGURE 9. Switch circuit configurations, schematics. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-22885/113A 10 FIGURE 10. LED circuit conf
45、igurations, schematics. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-22885/113A 11 NOTES: 1. Dimensions are in inches. Metric equivalents are given for general information only. 2. Unless otherwise specified, tolerances are .010 for three
46、place decimals and .03 for two place decimals. FIGURE 11. Recommended panel cutouts. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-22885/113A 12 FIGURE 12. Switch poles and lighting circuit terminal arrangements and identification. Provided
47、 by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-22885/113A 13 NOTES: 1. All 2 pole common termination system (CTS) switches have identical switch and lighting circuit terminal arrangement identification. All 4 pole CTS switches have identical switch
48、and lighting circuit terminal arrangement identification. 2. To make the various CTS combinations, an MS27488-20 sealing plug is placed in the locations not to be used. In the above identifications, blackened circles indicate where the sealing plugs shall be located to form the described variation. 3. “SKT“ identifies the socket side. 4. A and B or H, J, K and L identify each switch pole. 5. C, B, G, F, D, and A identify the lighting circuit terminations. 6. 1, 2, 3, and 4 identify the switch contact termination. FIGURE 12. S
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1