1、AMSC N/A FSC 5945 INCH-POUND MIL-PRF-6106/12F 1 November 2011 SUPERSEDING MIL-PRF-6106/12E 23 April 2001 PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC (TYPE I), MAGNETIC LATCH, 25 AMPERES, 3PNO MAIN CONTACTS, WITH 2 AMPERE 1PDT AUXILIARY CONTACTS, HERMETICALLY SEALED Inactive for new design
2、 after 15 November 2002. No superseding document. This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the relay described herein shall consist of this specification and the MIL-PRF-6106. FIGURE 1. Relay, outline drawing.
3、 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/12F 2 FIGURE 1. Relay, outline drawing - Continued. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/12F 3 Inches mm Inches mm
4、 Inches mm .001 0.03 .156 3.96 .600 15.24 .002 0.05 .172 4.37 .625 15.88 .003 0.08 .234 5.94 .630 16.00 .005 0.13 .250 6.35 .937 23.80 .020 0.51 .270 6.86 1.010 25.65 .040 1.02 .300 7.62 1.025 26.04 .050 1.27 .312 7.92 1.062 26.97 .062 1.57 .385 9.78 1.396 35.46 .093 2.36 .395 10.03 1.406 35.71 .117
5、 2.97 .432 10.97 1.446 36.73 .150 3.81 .450 11.43 1.718 43.64 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is .010 (0.25 mm). 4. There shall be affixed to the relay a legible circuit diagram that identifies
6、 each terminal location specified. 5. Notes to observe polarity must appear on relays. 6. To close main contact, (operate) energize X1 and X2. To open main contacts, (reset) energize Y1 and Y2. 7. Hook terminals will accept one no. 12 AWG stranded wire. 8. Socket pin terminals shall provide the oper
7、ational, environmental, and interface characteristics to provide a reliable interconnect to gold-plated contacts. Terminals shall be gold plated. Gold plating of the polarizing pin is optional. One system for gold plating that may be used is ASTM B488, type 3, class 1.25 with a nickel underplate of
8、50 to 150 microinches thick. The gold plating system shall enable the product to meet the performance requirements of this specification and shall be approved by the qualifying activity. 9. Gasket shall provide a reliable seal between the relay and mating socket that will meet the environmental, ope
9、rational, and interface requirements of the relay with the mating socket. The gasket shall have shore hardness 20 5, thickness .050 .005. Gasket material according to SAE-AMS 3332 has been considered acceptable. FIGURE 1. Relay, outline drawing - Continued. Provided by IHSNot for ResaleNo reproducti
10、on or networking permitted without license from IHS-,-,-MIL-PRF-6106/12F 4 REQUIREMENTS: Coil data: See table I. Rated contact load: See table II. Dimensions and configuration: See figure 1. Weight: 0.18 pound (81.64 grams) maximum. Temperature range 1/: -70C to +125C. Maximum altitude rating: 300,0
11、00 feet. Shock G-level: 200 g. Duration: 6 ms. Maximum duration contact opening: 10 s. Vibration-sinusoidal: 0.12 inch DA, 10 Hz - 70 Hz. 30 g, 70 Hz - 3,000 Hz. Vibration (random): Applicable specification: MIL-STD-202, method 214, test condition IG. Duration: 15 minutes, each plane. Acceleration:
12、15 gs Strength of terminals and mounting studs: Applicable. Terminal solderability: Applicable to solder pin and solder hook terminals only. Insulation resistance, initial: 100 megohms. After life or environmental tests: 50 megohms. 1/ For full rated load at maximum temperature and altitude, use no.
13、 12 wire or larger. Solder hook relays are to be mounted to limit mounting bracket temperature to +135C. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/12F 5 TABLE I. Operating characteristics. 1/ Caution: Use of any coil voltage less t
14、han the rated coil voltage will compromise the operation of the relay. 2/ Over the temperature range. 3/ With rated coil voltage. TABLE II. Rated contact load (amperes per pole) (case grounded). 1/ 2/ 3/ Type of load Life operating cycles x10328 V dc 115 V ac, 1 phase 115/200 V ac, 3 phase 1/ Main A
15、ux Main Aux Main Aux NO NC NO NC 400 Hz 60 Hz 400 Hz 60 Hz 400 Hz 60 Hz 400 Hz 2/ 60 Hz 4/ Resistive 50 25 2 2 25 2 25 Inductive 10 12 Inductive 10 1 1 15 1 15 Motor 50 10 10 10 Lamp 50 5 .5 .5 5 .5 5 5/ Transfer load Mechanical life reduced current 200 6 6 6 Intermediate current Applicable in accor
16、dance with MIL-PRF-6106 (main contacts only) Mixed loads Applicable in accordance with MIL-PRF-6106 1/ Absence of value indicates relay is not rated for 3 phase application. 2/ Single phase load shall be run during the 3 phase test on auxiliary contacts. 3/ Absence of value indicates parameter is no
17、t applicable to this specification sheet. 4/ For full rated load at maximum temperature and altitude, use no. 12 wire or larger. Solder hook relays shall be mounted to limit mounting bracket temperature to +135C. 5/ Transfer load indicates relay is suitable for transfer between unsynchronized ac pow
18、er supplies at the rating indicated. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/12F 6 Dielectric withstanding voltage (sea level): 2 to 5 seconds. Initial After life tests Coil to case and coil to coil - 1000 V rms 1000 V rms Auxili
19、ary contacts - 1000 V rms 750 V rms All other points - 1250 V rms 1000 V rms Dielectric withstanding voltage (altitude): 2/: 1 minute. 80,000 feet 300,000 feet Coil to case and coil to coil - 350 V rms 500 V rms Auxiliary contacts - 350 V rms 500 V rms All other points - 350 V rms 500 V rms Maximum
20、contact drop, initial 0.150 volt. After life tests: 0.175 volt. Overload current: 50 amperes dc, 80 amperes ac. Rupture current: 60 amperes dc, 100 amperes ac. Duty rating: Continuous. Part or identifying Number (PIN): M6106/12-(plus dash number from table I). Qualification by similarity: See MIL-PR
21、F-6106. 2/ Dielectric rating may be improved by suitable insulation of terminals and wiring after installation. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106/12F 7 Referenced documents: MIL-PRF-6106 MIL-STD-202 ASTM-B488 SAE-AMS3332 Th
22、e margins of this specification are marked with vertical lines to indicate where modifications from this revision were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evalua
23、te the requirements of this document based on the entire content irrespective of the marginal notations. Custodian: Preparing activity: Air Force - 85 DLA - CC DLA - CC (Project 5945-2011-042) Review activities: Air Force - 99 NOTE: The activities listed above were interested in this document as of
24、the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil/ . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有