1、AMSC N/A FSC 5945 MIL-PRF-6106M 14 September 2009 SUPERSEDING MIL-PRF-6106L 10 November 2000 PERFORMANCE SPECIFICATION RELAYS, ELECTROMAGNETIC GENERAL SPECIFICATION FOR This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This speci
2、fication establishes general requirements for electromechanical relays with contact ratings from 25 amperes resistive (unless otherwise specified) and upward for use in electrical applications. Auxiliary contacts may be rated at lower currents. Relays covered by this specification are capable of mee
3、ting the electrical and environmental requirements when mounted directly to the structure of aircraft, missile, spacecraft, ship, and other primary vehicles or in ground support and shipboard equipment. Other ratings may be as specified (see 3.1). CAUTION: The use of any coil voltage less than the r
4、ated coil voltage will compromise the operation of the relay. For additional application and caution information, see 6.1. 1.2 Classification. Relays covered by this specification will be classified by the type specified in 1.2.1 (see 3.1 and 6.1). 1.2.1 Type designators. The type is identified by o
5、ne of the following designators: Type I: Continuous duty, hermetically sealed. Type II: Continuous duty, unsealed. Type III: Intermittent duty (hermetically sealed, environmentally sealed, unsealed). Type IV: Continuous duty, environmentally sealed, (nonhermetic). 1.2.2 Class “O“ relays. Information
6、 concerning Class “O“ relays is covered in 6.11. 1.2.3 Part or Identifying Number (PIN). The PIN will consist of the letter “M“; the basic specification number; the specification sheet number; and an assigned dash number (see 3.1) as shown in the following example. (NOTE: The PIN format for relays c
7、overed by Military Standards (MS) sheets and Air Force-Navy (AN) Aeronautical standards are to be as specified therein; see 3.1.) M6106 /20 -001 I I I I I I I I I Specification Specification Dash number designator sheet number INCH-POUND Comments, suggestions or questions on this document should be
8、addressed to Defense Supply Center Columbus, ATTN: VAT, Post Office Box 3990, Columbus, OH 43218-3990, or emailed to relaydla.mil. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. Prov
9、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106M 2 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sect
10、ions of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3 and 4 of this specification, whe
11、ther or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the
12、solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-6106/12 - Relay, Electromagnetic, (Type I), Magnetic Latch, 25 Amperes, 3PNO Main Contacts, with 2 Ampere, 1PDT Auxillary Contacts, Hermetically Sealed. MIL-PRF-6106/13 - Relay, Electromagnetic, 25 Amperes, 3PST, NO, with 2 Amper
13、e, 1 PDT Auxiliary Contacts, Hermetically Sealed, Permanent Magnet Drive, Type I. MIL-PRF-6106/19 - Relay, Electromagnetic, Magnetic Latch, 25 Amperes, SPDT, Hermetically Sealed. MIL-PRF-6106/20 - Relay, Electromagnetic, Magnetic Latch, 25 Amperes, SPDT, Hermetically Sealed. MIL-PRF-6106/38 - Relay,
14、 Electromagnetic, Type I, Magnetic Latch, Permanent Magnet Drive, Low Level to 5 Amperes, 2 PDT, Hermetically Sealed. MIL-PRF-6106/39 - Relay, Electromagnetic, Type I Magnetic Latch, Permanent Magnet Drive, Low Level to 5 Amperes, 4 PDT, Hermetically Sealed. MIL-PRF-6106/40 - Relay, Electromagnetic,
15、 Type I, Magnetic Latch, Permanent Magnet Drive, Low Level to 10 Amperes, 3 PDT, Hermetically Sealed. (See supplement 1 for list of other specification sheets.) FEDERAL STANDARDS FED-STD-H28 - Screw Thread Standards for Federal Services. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-202 - Electronic and E
16、lectrical Component Parts. MIL-STD-750 - Semiconductor Devices, Test Methods for. MIL-STD-790 - Established Reliability and High Reliability Qualified Products List (QPL) Systems for Electrical, Electronic, and Fiber Optic Parts Specifications. MIL-STD-883 - Microelectronics. MIL-STD-1276 - Leads fo
17、r Electronic Component Parts. MIL-STD-1285 - Marking of Electrical and Electronic Parts. MS27742(USAF) - Relays, Electromagnetic, Type I, Magnetic Latch, 25 Amperes, 3 PDT, All Welded, Hermetically Sealed. (Copies of these documents are available online at http:/assist.daps.dla.mil/ or from the Stan
18、dardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solic
19、itation or contract. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) ANSI Y32.2 - Electrical and Electronics Diagrams. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106M 3 (Applications for copies are available online at http:/www.ansi.org or
20、 should be addressed to American National Standards Institute (ANSI), 11 West 42ndStreet, New York, NY 10036-8002.) AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTM D470 - Crosslinked Insulations and Jackets for Wire and Cable. (Application for copies are available online at http:/www.astm.org
21、 or should be addressed to ASTM International PO Box C700, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.) ELECTRONIC INDUSTRIES ASSOCIATION (EIA) EIA-557 - Statistical Process Control Systems. (Applications for copies are available online at http:/www.eia.org/ or should be addressed to th
22、e ECA/EIA Standards and Technology, 2500 Wilson Boulevard, Arlington, VA 22201-3834). SOCIETY OF AUTOMOTIVE ENGINEERS (SAE International) SAE-AS20659 - Terminal Lug, Crimp Style, Copper, Uninsulated, Ring-Tongue, Type I, Class 1, for 175C Total Conductor Temperature. SAE-AS25036 - Terminal Lug, Crim
23、p Style, Copper, Insulated, Ring-Tongue, Bell-mouthed, Type II, Class 1 (for 105C Total Conductor Temperature). (Applications for copies are available online at http:/www.sae.org/ or should be addressed to SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001.) 2.4 Order of precedence
24、. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein (except for related specification sheets), the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and re
25、gulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Specification sheets. The individual item requirements shall be as specified herein and in accordance with the applicable specification sheet. In the event of any conflict between the requirements of this specification and
26、the specification sheet, the latter shall govern. 3.2 Qualification. The relays furnished under this specification shall be a product which has been tested, and has passed the qualification inspection specified herein, and has been listed on or approved for listing on the applicable Qualified Produc
27、ts List (QPL). 3.2.1 Qualification and maintenance by similarity. Relays furnished under this specification may be qualified and maintained by similarity with other relays in the generic family. Manufacturers which desire to qualify and maintain products in this same manner shall request this method
28、 from the qualifying activity. The manufacturer shall submit their test plans for the qualifying activity to evaluate. The following are example of items to be included in the request, but are not inclusive. a. Difference between relays. b. Tests for each relay. c. Characteristics of each relay such
29、 as: Contact assembly Coil assembly External material Contact material Coil wire size Case material Contact size Coil bobbin Plating Contact configuration Ampere turns Welding process Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106M 4 d.
30、 Any other items that may be affected by the differences in design. 3.3 QPL system. The manufacturer shall establish and maintain a QPL system for parts covered by this specification. Requirements for this system are specified in MIL-STD-790. In addition, the manufacturer shall also establish a Stat
31、istical Process Control (SPC) system that meets the requirements in 3.3.1. “Inactive for New Design“ specification sheets, MS sheets, or AN standards are not required to be compliant with MIL-STD-790. 3.3.1 SPC. The contractor shall implement and use SPC techniques in the manufacturing process for p
32、arts covered in this specification. The SPC program shall be developed and maintained in accordance with EIA-557 or an equivalent system as approved by the qualifying activity. The SPC program shall be documented and maintained as part of the overall product assurance program as specified in MIL-STD
33、-790. Inactive for New Design” specification sheets, MS sheets, or AN standards do not require the implementation and use of a SPC program. 3.4 Materials. Materials used externally shall be fungus inert (see 6.12), self-extinguishing, and shall not support combustion, nor give off noxious gases in h
34、armful quantities. Materials used internally shall not give off gases in quantities sufficient to cause explosion of sealed enclosures, cause contamination of the contacts or other parts of the relay that will adversely affect life or reliability, or form current-carrying tracks when subjected to an
35、y of the tests specified herein. The use of silicone or silicone compounds internally for any purpose is prohibited. The use of silicone elastomers internally for relays fully rated 25 amperes and above is acceptable. The selection of materials shall be such as to provide maximum shelf life. Accepta
36、nce or approval of any constituent material shall not be construed as a guaranty of the acceptance of the finished product. 3.4.1 Metals. Metals shall be of a corrosion-resistant type or shall be plated or treated to resist corrosion. The use of mercury or mercury compounds is prohibited. The use of
37、 magnesium or magnesium alloys is prohibited (not applicable to contact systems). 3.4.1.1 Plated finishes. a. Pure tin plating is prohibited internally and externally. Tin-lead finish is acceptable, provided that the minimum lead content is 3 percent. Other tin alloys are acceptable as approved by t
38、he qualifying activity. b. Pure zinc plating is prohibited internally and externally. c. Pure cadmium plating is prohibited internally and externally. 3.4.1.2 Dissimilar metals. When dissimilar metals are used in intimate contact with each other, protection against electrolysis and corrosion shall b
39、e provided. The use of dissimilar metals in contact, which tends toward active electrolytic corrosion (particularly brass, copper, or steel used in contact with aluminum or aluminum alloy), is not acceptable. However, metal spraying or metal plating of dissimilar base metals to provide similar or su
40、itable abutting surfaces is permitted. Dissimilar metals should be as defined in 6.6. In hermetic seals, the 0.25 volt difference between the header material and the housing material is not applicable. 3.4.2 Magnet wire. Magnet wire shall be of such quality as to ensure that the relay meets all the
41、performance requirements of this specification. 3.4.3 Plastic. Plastic shall be of such quality as to ensure that the relay meets all the performance requirements of this specification 3.4.4 Ceramic. Ceramic shall be of such quality as to ensure that the relay meets all the performance requirements
42、of this specification. 3.5 Interface and construction. Relays shall meet the interface and construction requirements specified in 3.1 (such as weight or physical dimensions). 3.5.1 Attitude. Relays shall be constructed so as to ensure their proper operation when mounted in any position. 3.5.2 Mounti
43、ng brackets. When mounting brackets are used, they shall be an integral part of the relay housing or Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6106M 5 shall be securely attached thereto in a manner to prevent any movement between the re
44、lay and the mounting bracket in service use. 3.5.3 Enclosures. Enclosures shall be of sufficient mechanical strength to withstand the normal abuse incurred in handling, transit, storage, and installation without causing malfunction or distortion of parts. The case shall not form part of the contact
45、or coil electrical circuits, but it may be part of the magnetic circuit. 3.5.3.1 Unsealed enclosures. Unsealed relays shall be totally enclosed for mechanical and dust protection and shall be explosion-proof (see 3.23). The enclosure design shall be such that pressure differentials cannot exist betw
46、een the inside and outside to aggravate the moisture accumulation problem. The cover shall be rugged in design, constructed of high impact materials, and securely mounted to the relay. Metal covers shall be provided with a means for grounding as specified (see 3.1). 3.5.3.2 Hermetic sealing process.
47、 Relays shall be dried, degassed, and backfilled with an atmosphere and sealed such that the requirements of this specification are met. Adjunct sealant (see 6.11), if used, must comply with the following characteristics: a. Shall not extend above 20 percent of the length of the exposed terminals ab
48、ove the glass meniscus. b. Trace color is permitted if it is a natural result of the sealant process. Trace color shall not obscure identification of contrasting glass color. c. Shall form, after curing, a permanent nonconductive, noncracking seal under all relay environments. 3.5.3.2.1 Hermetic sea
49、l rework. After the cover has been welded to the header, no rework shall be performed that requires removal of the cover from the header. Relays whose lowest specified load (resistive, inductive, and motor) for the power contacts is 25 amperes or greater are exempt from this requirement. Relays that have been reworked shall be resubmitted for group A inspection after rework. 3.5.3.3 Environmentally
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1