1、 MS53063B 18 January 2011 SUPERSEDING MS53063A 20 February 1969 DETAIL SPECIFICATION SHEET INDICATOR, AIR CLEANER, INTAKE, RESTRICTION MECHANICAL TYPE This specification is approved for use by all Departments and Agencies of the Department of Defense. The requirements for acquiring the product descr
2、ibed herein shall consist of this specification sheet. NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for information only. 3. All tolerances are 0.030 (0.762 mm), unless otherwise specified. 4. This drawing is intended for identification purposes only and is not intended to res
3、trict design and shapes not dimensioned. FIGURE 1. Air cleaner, indicator. 2.18 MAX. .688 .688 4.63 MAX. 2.25 MAX. PROVIDE 1/32 GASKET VACUUM CONNECTION 1/8 -27 NPT (ADDITIONAL TOP CONNECTION IS OPTIONAL) FIGURE 2. Fitting. FILTER DISC 10-25 MICRON STAKED OVER (PIPE END) .281 DIA 2 HOLES Inches mm 4
4、.63 118 2.25 57 2.18 55 .688 17 .281 7 INCH-POUND Inactive for new design after 22 January 1999. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MS53063B 2 REQUIREMENTS Indicator shall be as specified on figure 1 and in table I. A manually actuated r
5、eset button shall be provided to reactivate the warning signal after maximum signaling point has been reached. The location of the reset button is optional. The signal window shall be .250 .0625 inch (6.35mm 1.59mm) high and shall extend a minimum of 180 around the frontal circumference of the case.
6、 The indicator shall operate in the upright or inclined position. The operating mechanism shall be shielded against oil, dust and moisture. TABLE I. Maximum signal point. Part or Indentifying Number (PIN) Former PIN Maximum signaling point (inch water) MS53063-1 15 MS53063-2 ORD 8712057-1 20 MS53063
7、-3 25 MS53063-4 ORD 8712057 27 MS53063-5 30 One each of the following fittings shall be furnished with each air cleaner restriction indicator. a. Connector, Flared Tube, Male Pipe End: .250 Tube, .125 - 27 NPT Pipe, SAE J5124-2010102B. b. Connector, with built in safety filter, (See figure 2, .250 t
8、ube, .125-27 NPT pipe, SAE J5124-2010102B modified). Marking shall be in accordance with MIL-STD-130 and shall include the following data: a. Air cleaner restriction indicator b. Maximum signaling point (in water) c. MS PIN d. Manufactures PIN e. Manufactures name or CAGE code An instruction sheet,
9、covering installation and operating procedures, shall be furnished with each indicator. Gasket shall be of a suitable non-metallic material conforming to the requirements of ASTM F36. Referenced documents shall be the latest revision in effect on date of invitation for bid. For design feature purpos
10、es, this standard takes precedence over procurement documents referenced herein. Changes from previous issue. Marginal notations are not used in this revision to identify changes due to the extent of the changes. Provided by IHSNot for ResaleNo reproduction or networking permitted without license fr
11、om IHS-,-,-MS53063B 3 Referenced documents. This document references the following. MIL-STD-130 ASTM F36 CONCLUDING MATERIAL Custodians: Preparing activity: Army - AV DLA - CC Navy - AS Air Force - 99 (Project 2940-2010-003) DLA - CC Review activities: Navy - MC, SA Air Force - 71 NOTE: The activiti
12、es listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https:/assist.daps.dla.mil. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-