1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Update drawing to current requirements. Editorial changes throughout. - gap 07-03-14 Robert M. Heber CURRENT CAGE CODE IS 67268 The original first sheet of this drawing has been replaced. REV SHET REV SHET REV STATUS REV A A A A A A A A OF SHEETS
2、 SHEET 1 2 3 4 5 6 7 8 PMIC N/A PREPARED BY David W. Queenan DEFENSE SUPPLY CENTER COLUMBUS STANDARD MICROCIRCUIT DRAWING CHECKED BY D. A. DiCenzo COLUMBUS, OHIO 43216 http:/www.dscc.dla.mil THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Robert P. Evans MICROCIRCUIT, DIGITAL, ADVAN
3、CED LOW POWER SCHOTTKY TTL, AND GATES AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 84-08-23 MONOLITHIC SILICON AMSC N/A REVISION LEVEL A SIZE A CAGE CODE 14933 84097 SHEET 1 OF 8 DSCC FORM 2233 APR 97 5962-E151-07 Provided by IHSNot for ResaleNo reproduction or networking permitte
4、d without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 84097 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing describes device requirements for MIL-STD-883 compliant, non-JAN class level B microcircu
5、its in accordance with MIL-PRF-38535, appendix A. 1.2 Part or Identifying Number (PIN). The complete PIN is as shown in the following example: 84097 01 B X Drawing number Device type (see 1.2.1) Case outline(see 1.2.2) Lead finish(see 1.2.3)1.2.1 Device type(s). The device type(s) identify the circu
6、it function as follows: Device type Generic number Circuit function 01 54ALS1008A Quadruple 2-input AND gate, buffer output 1.2.2 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style B GDFP4-F14 14 Flat p
7、ackage C GDIP1-T14 or CDIP2-T14 14 Dual-in-line package D GDFP1-F14 or CDFP2-F14 14 Flat package 2 CQCC1-N20 20 Square leadless chip carrier 1.2.3 Lead finish. The lead finish is as specified in MIL-PRF-38535, appendix A. 1.3 Absolute maximum ratings. Supply voltage range . -0.5 V dc to +7.0 V dc In
8、put voltage range . -1.5 V dc at -18 mA to 7.0 V dc Storage temperature range . -65C to +150C Maximum power dissipation, (PD) per device 1/ . 44 mW dc Lead temperature (soldering, 10 seconds) +300C Thermal resistance, junction-to-case (JC) See MIL-STD-1835 Junction temperature (TJ) +175C 1.4 Recomme
9、nded operating conditions. Supply voltage (VCC) . 4.5 V dc minimum to 5.5 V dc maximum Minimum high-level input voltage (VIH) 2.0 V dc Maximum low-level input voltage (VIL) . 0.8 V dc Case operating temperature range (TC) -55C to +125C _ 1/ Must withstand the added PDdue to short circuit test; e.g.,
10、 IOS. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 84097 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 3 DSCC FORM 2234 APR 97 2. APPLICABLE DOCUMENTS 2.1 Government specificat
11、ion, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards
12、(DoDISS) and supplement thereto, cited in the solicitation. 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those ci
13、ted in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard Electronic Component Case Outlin
14、es. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at http:/assist.daps.dla.mil;quicksearch/ or www.dodssp.daps.mil or from the Standardization Document Order Desk,
15、700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulation
16、s unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535, appendix A for non-JAN class level B devices and as specified herein. Product built to this drawing that is produced by a Qualified Manu
17、facturer Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional certification to MIL-PRF-38535 may be processed as QML product in accordance with the manufacturers approved program plan and qualifying activity approval in accordance with MIL-PRF-38535.
18、 This QML flow as documented in the Quality Management (QM) plan may make modifications to the requirements herein. These modifications shall not affect form, fit, or function of the device. These modifications shall not affect the PIN as described herein. A “Q“ or “QML“ certification mark in accord
19、ance with MIL-PRF-38535 is required to identify when the QML flow option is used 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38535, appendix A and herein. 3.2.1 Case outlines. The case outlines shall be in acco
20、rdance with 1.2.4. 3.2.2 Logic diagram and terminal connections. The logic diagram and terminal connections shall be as specified on figure 1. 3.2.3 Truth table. The truth table shall be as specified on figure 2. 3.3 Electrical performance characteristics. Unless otherwise specified herein, the elec
21、trical performance characteristics are as specified in table I and shall apply over the full case operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are described in tabl
22、e I. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 84097 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 4 DSCC FORM 2234 APR 97 3.5 Marking. Marking shall be in accordance with M
23、IL-PRF-38535, appendix A. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers PIN may also be marked. 3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in compliance to MIL-PRF-38535, appendix A. The co
24、mpliance indicator “C” shall be replaced with a “Q“ or “QML“ certification mark in accordance with MIL-PRF-38535 to identify when the QML flow option is used 3.6 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an approved source o
25、f supply in MIL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DSCC-VA prior to listing as an approved source of supply shall affirm that the manufacturers product meets the requirements of MIL-PRF-38535, appendix A and the requirements herein. 3.7 Certificate of conformance.
26、A certificate of conformance as required in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits delivered to this drawing. 3.8 Notification of change. Notification of change to DSCC-VA shall be required for any change that affects this drawing. 3.9 Verification and review. DSC
27、C, DSCCs agent, and the acquiring activity retain the option to review the manufacturers facility and applicable required documentation. Offshore documentation shall be made available onshore at the option of the reviewer. 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspection procedur
28、es shall be in accordance with MIL-PRF-38535, appendix A. 4.2 Screening. Screening shall be in accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices prior to quality conformance inspection. The following additional criteria shall apply: a. Burn-in test, method 1015 of MIL
29、-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipatio
30、n, as applicable, in accordance with the intent specified in method 1015 of MIL-STD-883. (2) TA= +125C, minimum. b. Interim and final electrical test parameters shall be as specified in table II herein, except interim electrical parameter tests prior to burn-in are optional at the discretion of the
31、manufacturer. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 84097 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 5 DSCC FORM 2234 APR 97 TABLE I. Electrical performance character
32、istics. Test Symbol Conditions 1/ -55C TC +125C Group A subgroups Limits Unit unless otherwise specified Min Max High level output voltage VOHVCC= 4.5 V, IOH= -1.0 mA, VIH= 2.0 V, VIL= 0.8 V 1, 2, 3 2.4 - - - V dc Low level output voltage VOLVCC= 4.5 V, IIN= 12 mA, VIL= 0.8 V, VIH= 2.0 V 1, 2, 3 - -
33、 - 0.4 V dc Input clamp voltage VICVCC= 4.5 V, IIN= -18 mA TC= +25C 1 - - - -1.5 V dc Low level input current IILVCC= 5.5 V, VIN= 0.4 V 1, 2, 3 0 -100 A High level input current IIH1VCC= 5.5 V, VIN= 2.7 V 1, 2, 3 20 A IIH2VCC= 5.5 V, VIN= 7.0 V 1, 2, 3 100 A Output current 1/ IOVCC= 5.5 V, VO= 2.25
34、V 1, 2, 3 -15 -112 mA Supply current, outputs high ICCHVCC= 5.5 V 1, 2, 3 3 mA Supply current, outputs low ICCLVCC= 5.5 V 1, 2, 3 9.3 mA Propagation delay time low- to-high level tPLHVCC= 5.0 V, CL= 50 pF 10%, 9, 10, 11 11 ns Propagation delay time high- to-low level tPHLRL= 500 9, 10, 11 11 ns 1/ T
35、he output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 84097 DEFENSE SUPPLY CEN
36、TER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 6 DSCC FORM 2234 APR 97 CASE 2FIGURE 1. Logic diagram and terminal connections (top view). TRUTH TABLE (EACH GATE) INPUTS OUTPUT A B Y L L L H L L L H L H H H Y = AB FIGURE 2. Truth table. Provided by IHSNot for ResaleNo reproduction or n
37、etworking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 84097 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 7 DSCC FORM 2234 APR 97 TABLE II. Electrical test requirements. MIL-STD-883 test requirements Subgroups (in accordance with MIL-
38、STD-883, method 5005, table I) Interim electrical parameters (method 5004) - - - Final electrical test parameters (method 5004) 1*, 2, 3, 9 Group A test requirements (method 5005) 1, 2, 3, 7, 9 Groups C and D end-point electrical parameters (method 5005) 1, 2, 3 Additional electrical subgroups for g
39、roup C periodic inspections 10, 11* * PDA applies to subgroup 1. * Subgroups 10 and 11, if not tested, shall be guaranteed to the specified limits in table I. 4.3 Quality conformance inspection. Quality conformance inspection shall be in accordance with method 5005 of MIL-STD-883 including groups A,
40、 B, C, and D inspections. The following additional criteria shall apply. 4.3.1 Group A inspection. a. Tests shall be as specified in table II herein. b. Subgroups 4, 5, 6, and 8 in table I, method 5005 of MIL-STD-883 shall be omitted. c. Subgroup 7 shall include verification of the truth table. 4.3.
41、2 Groups C and D inspections. a. End-point electrical parameters shall be as specified in table II herein. b. Steady-state life test conditions, method 1005 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level contro
42、l and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of MIL-STD-883. (2) TA= +125C, minimum. (3) Test duration: 1,000
43、 hours, except as permitted by method 1005 of MIL-STD-883. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 84097 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 8 DSCC FORM 2234 APR
44、 97 5. PACKAGING 5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A. 6. NOTES 6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications (original equipment), design applicatio
45、ns, and logistics purposes. 6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-prepared specification or drawing. 6.3 Configuration control of SMDs. All proposed changes to existing SMDs will be coordinated with the users of record
46、for the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal. 6.4 Record of users. Military and industrial users shall inform Defense Supply Center Columbus (DSCC) when a system application requires configuration control and the applicable SMD.
47、 DSCC will maintain a record of users and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronics devices (FSC 5962) should contact DSCC-VA, telephone (614) 692-0544. 6.5 Comments. Comments on this drawing should be directed to
48、 DSCC-VA, Columbus, Ohio 43218-3990, or telephone (614) 692-0547. 6.6 Approved sources of supply. Approved sources of supply are listed in MIL-HDBK-103. The vendors listed in MIL-HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been submitted to and accepted by DSCC-VA. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING BULLETIN DATE: 07-03-14 Approved sources of supply for SMD 84097 are listed below for immedi
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有