1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Page 5, table I: Add VCC= 6 V test. Editorial changes throughout. 87-01-15 N. A. HAUCK B Changes in accordance with N.O.R. 5962-R174-96. 96-07-10 M. A. FRYE C Drawing updated to reflect current requirements. Redrawn. - ro 06-10-11 R. MONNIN D Upd
2、ate drawing as part of 5 year review. -rrp 12-06-19 C. SAFFLE CURRENT CAGE CODE 67268 THE ORIGINAL FIRST SHEET OF THIS DRAWING HAS BEEN REPLACED. REV SHEET REV SHEET REV STATUS REV D D D D D D D D OF SHEETS SHEET 1 2 3 4 5 6 7 8 PMIC N/A PREPARED BY DONALD R. OSBORNE DLA LAND AND MARITIME COLUMBUS,
3、OHIO 43218-3990 http:/www.landandmaritime.dla.mil STANDARD MICROCIRCUIT DRAWING THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE CHECKED BY D. A. DiCENZO APPROVED BY D. A. DiCENZO MICROCIRCUIT, LINEAR, ULTRA HIGH FREQUENCY OPERATIONAL AMPLIFIER, MONOLITH
4、IC SILICON DRAWING APPROVAL DATE 86-05-14 AMSC N/A REVISION LEVEL D SIZE A CAGE CODE 14933 5962-86064 SHEET 1 OF 8 DSCC FORM 2233 APR 97 5962-E400-12 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-86064 DLA
5、LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing describes device requirements for MIL-STD-883 compliant, non-JAN class level B microcircuits in accordance with MIL-PRF-38535, appendix A. 1.2 Part or Identifying Number (PIN).
6、 The complete PIN is as shown in the following example: 5962-86064 01 C A Drawing number Device type (see 1.2.1) Case outline (see 1.2.2) Lead finish (see 1.2.3) 1.2.1 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function 01 5539 Ult
7、ra high frequency operational amplifier external compensation 1.2.2 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style C GDIP1-T14 or CDIP2-T14 14 dual-in-line 1.2.3 Lead finish. The lead finish is as s
8、pecified in MIL-PRF-38535, appendix A. 1.3 Absolute maximum ratings. Supply voltage (V+) . 12 V dc Power dissipation (PD) . 550 mW Lead temperature (solder, 10 seconds) 300C Junction temperature (TJ) . 150C Storage temperature range . -65C to +150C Thermal resistance, junction-to-case (JC) . See MIL
9、-STD-1835 Thermal resistance, junction-to-ambient (JA) 110C/W 1.4 Recommended operating conditions. Supply voltage . 8 V dc Common mode voltage range . 1.7 V dc Ambient operating temperature range (TA) -55C to +125C Provided by IHSNot for ResaleNo reproduction or networking permitted without license
10、 from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-86064 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 3 DSCC FORM 2234 APR 97 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a pa
11、rt of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for. DEPARTMENT OF DEFENSE STAND
12、ARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available
13、online at https:/assist.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the references cited herein, the text of this drawing
14、takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-38535, appendix A for non-JAN class level B devic
15、es and as specified herein. Product built to this drawing that is produced by a Qualified Manufacturer Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional certification to MIL-PRF-38535 may be processed as QML product in accordance with the manufact
16、urers approved program plan and qualifying activity approval in accordance with MIL-PRF-38535. This QML flow as documented in the Quality Management (QM) plan may make modifications to the requirements herein. These modifications shall not affect form, fit, or function of the device. These modificat
17、ions shall not affect the PIN as described herein. A “Q“ or “QML“ certification mark in accordance with MIL-PRF-38535 is required to identify when the QML flow option is used. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified i
18、n MIL-PRF-38535, appendix A and herein. 3.2.1 Case outline. The case outline shall be in accordance with 1.2.2 herein. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 1. 3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical
19、 performance characteristics are as specified in table I and shall apply over the full ambient operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical tests for each subgroup are described in table I
20、. 3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers PIN may also be marked. 3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices buil
21、t in compliance to MIL-PRF-38535, appendix A. The compliance indicator “C” shall be replaced with a “Q“ or “QML“ certification mark in accordance with MIL-PRF-38535 to identify when the QML flow option is used. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from
22、 IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-86064 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 4 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions 1/ -55C TA +125C VCC= 8 V Group A subgroups Device type Limits Unit unless o
23、therwise specified Min Max Input offset voltage VOSVO= 0 V, RS= 100 1 01 3 mV 2,3 5 Input offset current IOS1 01 1 A 2,3 3 Input bias current IB1 01 13 A 2,3 25 Common mode rejection ratio CMRR F = 1 kHz, RS= 100 , 1 01 70 dB VCM= 1.7 V 2,3 70 Output voltage swing VOUT+Swing, R1= 2 k to GND 4 01 2.5
24、 V -Swing, R1= 2 k to GND -2.0 +Swing, R1= 2 k to GND 5,6 2.3 -Swing, R1= 2 k to GND -1.5 Positive supply current ICC+VO= 0, R1= 1 01 17 mA 2,3 18 Negative supply current ICC-VO= 0, R1= 1 01 14 mA 2,3 15 Power supply rejection ratio PSRR VCC= 1 V 1,2,3 01 1,000 V/V Large signal voltage gain AVOLVO=
25、+2.5 V, -2.0 V 4 01 48 58 dB RL= 2 k to GND 5,6 46 60 See footnote at end of table. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-86064 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET
26、 5 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics Continued. Test Symbol Conditions 1/ -55C TA +125C VCC= 6 V Group A subgroups Device type Limits Unit unless otherwise specified Min Max Input offset voltage VOS1 01 3 mV 2,3 5 Input offset voltage IOS1 01 1 A 2,3 3 Input bias
27、voltage IB1 01 10 A 2,3 20 Common mode rejection ratio CMRR VCM= 1.3 V, RS= 100 1 01 70 dB Positive supply current ICC+1 01 13 mA 2,3 14 Negative supply current ICC-1 01 10 mA 2,3 11 Power supply rejection ratio PSRR VCC= 1 V 1,2,3 01 1,000 V/V Output voltage swing VOUTRL= 150 to GND and 390 to -VCC
28、, +Swing 4 01 1.5 V RL= 150 to GND and 390 to -VCC, -Swing -1.4 RL= 150 to GND and 390 to -VCC, +Swing 5,6 1.4 RL= 150 to GND and 390 to -VCC, -Swing -1.1 1/ Differential input voltage should not exceed 0.25 volt to prevent excessive input bias current and common mode voltage 2.5 volts. These voltag
29、e limits may be exceeded if current limit is 10 mA. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-86064 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 6 DSCC FORM 2234 APR 97 Device
30、type 01 Case outline C Terminal number Terminal symbol 1 +INPUT 2 NC 3 -VSUPPLY4 NC 5 VOSADJ / AV ADJ 6 NC 7 GND 8 OUTPUT 9 NC 10 +V 11 NC 12 FREQUENCY COMPENSATION 13 NC 14 -INPUT NC = No connection FIGURE 1. Terminal connections. Provided by IHSNot for ResaleNo reproduction or networking permitted
31、 without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-86064 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 7 DSCC FORM 2234 APR 97 3.6 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an ap
32、proved source of supply in MIL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DLA Land and Maritime -VA prior to listing as an approved source of supply shall affirm that the manufacturers product meets the requirements of MIL-PRF-38535, appendix A and the requirements herein.
33、 3.7 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits delivered to this drawing. 3.8 Notification of change. Notification of change to DLA Land and Maritime -VA shall be required for any change that aff
34、ects this drawing. 3.9 Verification and review. DLA Land and Maritime, DLA Land and Maritimes agent, and the acquiring activity retain the option to review the manufacturers facility and applicable required documentation. Offshore documentation shall be made available onshore at the option of the re
35、viewer. 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535, appendix A. 4.2 Screening. Screening shall be in accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices prior to quality conformance inspectio
36、n. The following additional criteria shall apply: a. Burn-in test, method 1015 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to the preparing or acquiring activity upon requ
37、est. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1015 of MIL-STD-883. (2) TA= +125C, minimum. b. Interim and final electrical test parameters shall be as specified in table II herein, except inter
38、im electrical parameter tests prior to burn-in are optional at the discretion of the manufacturer. 4.3 Quality conformance inspection. Quality conformance inspection shall be in accordance with method 5005 of MIL-STD-883 including groups A, B, C, and D inspections. The following additional criteria
39、shall apply. 4.3.1 Group A inspection. a. Tests shall be as specified in table II herein. b. Subgroups 7, 8, 9, 10, and 11 in table I, method 5005 of MIL-STD-883 shall be omitted. 4.3.2 Groups C and D inspections. a. End-point electrical parameters shall be as specified in table II herein. b. Steady
40、-state life test conditions, method 1005 of MIL-STD-883. (1) Test condition A, B, C, or D. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify th
41、e inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of MIL-STD-883. (2) TA= +125C, minimum. (3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883. Provided by IHSNot for ResaleNo reproduction or networkin
42、g permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-86064 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL D SHEET 8 DSCC FORM 2234 APR 97 TABLE II. Electrical test requirements. MIL-STD-883 test requirements Subgroups (in accordance with MIL-STD-883, met
43、hod 5005, table I) Interim electrical parameters (method 5004) - Final electrical test parameters (method 5004) 1*, 2, 3, 4 Group A test requirements (method 5005) 1, 2, 3, 4, 5, 6 Groups C and D end-point electrical parameters (method 5005) 1 * PDA applies to subgroup 1. 5. PACKAGING 5.1 Packaging
44、requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A. 6. NOTES 6.1 Intended use. Microcircuits conforming to this drawing are intended for use for Government microcircuit applications (original equipment), design applications, and logistics purposes. 6.2
45、 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-prepared specification or drawing. 6.3 Configuration control of SMDs. All proposed changes to existing SMDs will be coordinated with the users of record for the individual documents. T
46、his coordination will be accomplished using DD Form 1692, Engineering Change Proposal. 6.4 Record of users. Military and industrial users shall inform DLA Land and Maritime when a system application requires configuration control and the applicable SMD to that system. DLA Land and Maritime will main
47、tain a record of users and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronics devices (FSC 5962) should contact DLA Land and Maritime -VA, telephone (614) 692-0544. 6.5 Comments. Comments on this drawing should be directed
48、 to DLA Land and Maritime -VA, Columbus, Ohio 43218-3990, or telephone (614) 692-0540. 6.6 Approved sources of supply. Approved sources of supply are listed in MIL-HDBK-103. The vendors listed in MIL-HDBK-103 have agreed to this drawing and a certificate of compliance (see 3.6 herein) has been submitted to and accepted by DLA Land and Maritime -VA. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT