1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Update boilerplate paragraphs to current MIL-PRF-38535 requirements. - ro 12-08-16 C. SAFFLE THE ORIGINAL FIRST SHEET OF THIS DRAWING HAS BEEN REPLACED. REV SHEET REV SHEET REV STATUS REV A A A A A A A A OF SHEETS SHEET 1 2 3 4 5 6 7 8 PMIC N/A P
2、REPARED BY RICK C. OFFICER DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.landandmaritime.dla.mil STANDARD MICROCIRCUIT DRAWING THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE CHECKED BY CHARLES E. BESORE APPROVED BY MICHAEL A. FRYE MICROCIRC
3、UIT, LINEAR, FIXED POSITIVE 5 VOLT, 5 AMP VOLTAGE REGULATOR, MONOLITHIC SILICON DRAWING APPROVAL DATE 92-03-17 AMSC N/A REVISION LEVEL A SIZE A CAGE CODE 67268 5962-89873 SHEET 1 OF 8 DSCC FORM 2233 APR 97 5962-E272-11 Provided by IHSNot for ResaleNo reproduction or networking permitted without lice
4、nse from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-89873 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing describes device requirements for MIL-STD-883 compliant, non-JAN class level B microcircuits in accordance
5、with MIL-PRF-38535, appendix A. 1.2 Part or Identifying Number (PIN). The complete PIN is as shown in the following example: 5962-89873 01 Y A Drawing number Device type (see 1.2.1) Case outline (see 1.2.2) Lead finish (see 1.2.3) 1.2.1 Device type(s). The device type(s) identify the circuit functio
6、n as follows: Device type Generic number Circuit function 01 LT1003 Fixed positive 5 volt, 5 amp voltage regulator 1.2.2 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style Y See figure 1 2 TO-3 flange m
7、ount 1.2.3 Lead finish. The lead finish is as specified in MIL-PRF-38535, appendix A. 1.3 Absolute maximum ratings. Input voltage (VIN) 20 V dc Power dissipation (PD) . Internally limited Output current (IOUT) 5 A Junction temperature (TJ) . +150C Storage temperature range . -65C to +150C Lead tempe
8、rature (soldering, 10 seconds) +300C Thermal resistance, junction-to-case (JC) . See MIL-STD-1835 Thermal resistance, junction-to-ambient (JA) 35C/W 1.4 Recommended operating conditions. Input voltage range (VIN) 7.5 V dc to 15 V dc Ambient operating temperature range (TA) . -55C to +125C Provided b
9、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-89873 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 3 DSCC FORM 2234 APR 97 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and
10、handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38535 - Integrated Circu
11、its, Manufacturing, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Microcircuits. MIL-STD-1835 - Interface Standard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 -
12、 Standard Microcircuit Drawings. (Copies of these documents are available online at https:/assist.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2 Order of precedence. In the event of a conflict between the text
13、of this drawing and the references cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements shall be in
14、 accordance with MIL-PRF-38535, appendix A for non-JAN class level B devices and as specified herein. Product built to this drawing that is produced by a Qualified Manufacturer Listing (QML) certified and qualified manufacturer or a manufacturer who has been granted transitional certification to MIL
15、-PRF-38535 may be processed as QML product in accordance with the manufacturers approved program plan and qualifying activity approval in accordance with MIL-PRF-38535. This QML flow as documented in the Quality Management (QM) plan may make modifications to the requirements herein. These modificati
16、ons shall not affect form, fit, or function of the device. These modifications shall not affect the PIN as described herein. A “Q“ or “QML“ certification mark in accordance with MIL-PRF-38535 is required to identify when the QML flow option is used. 3.2 Design, construction, and physical dimensions.
17、 The design, construction, and physical dimensions shall be as specified in MIL-PRF-38535, appendix A and herein. 3.2.1 Case outline. The case outline shall be in accordance with 1.2.2 herein and figure 1. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 1. 3.3 El
18、ectrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are as specified in table I and shall apply over the full ambient operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups
19、 specified in table II. The electrical tests for each subgroup are described in table I. 3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers PIN may also be marked. For packages where m
20、arking of the entire SMD PIN number is not feasible due to space limitations, the manufacturer has the option of not marking the “5962-“ on the device. 3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in compliance to MIL-PRF-38535, appendi
21、x A. The compliance indicator “C” shall be replaced with a “Q“ or “QML“ certification mark in accordance with MIL-PRF-38535 to identify when the QML flow option is used. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SI
22、ZE A 5962-89873 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 4 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions -55C TA +125C Group A subgroups Device type Limits 1/ Unit unless otherwise specified Min Max Output voltage VOUTVIN=
23、 7.5 V, IOUT= 0 1 01 4.9 5.1 V 0 A IOUT 5 A, P 30 W, 7.5 V VIN 15 V 1,2,3 4.8 5.2 Line regulation VRLN7.5 V VIN 15 V 2/ 1 01 -15 15 mV 2,3 -30 30 Load regulation VRLDVIN= 7.5 V, 2/ 1 01 -100 100 mV 0 A IOUT 5 A 2,3 -150 150 Thermal regulation 20 ms per pulse, TA= +25C 1 01 0.02 %/W Quiescent current
24、 IQ7.5 V VIN 15 V, 0 A IOUT 5 A 1,2,3 01 20 mA Ripple rejection VIN= 10 V, Vrip= 2.5 V, 3/ 4/ no load 4 01 56 dB Short circuit current limit ISCVIN= 15 V, TA= +25C 1 01 8 A VIN= 7.5 V, TA= +25C 9 Long term stability t = 1000 hours, TA= +125C 3/ 8A 01 -35 35 mV 1/ The algebraic convention, whereby th
25、e most negative value is a minimum and the most positive is a maximum, is used in this table. 2/ Load and line regulation are tested with pulsed low duty cycle techniques where pulse width 1 ms and duty cycle 5 percent. 3/ If not tested, shall be guaranteed to the limits specified in table I herein.
26、 4/ Vrip= 1/2 p-p capacitor ripple voltage. The filter capacitor should be 2000 F per ampere of load current. Vrip= ( 5.3 x 10-3) ( IOUT) / 2C. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-89873 DLA LAND A
27、ND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 5 DSCC FORM 2234 APR 97 FIGURE 1. Case outline and terminal connections. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-89873 DLA LAND AND MARITIM
28、E COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 6 DSCC FORM 2234 APR 97 Symbol Dimensions Inches Millimeters Notes Min Max Min Max A .250 .352 6.35 8.94 A11.177 1.197 29.90 30.40 b .038 .043 0.97 1.09 3 D - .875 - 22.22 e .655 .675 16.64 17.14 e1.420 .440 10.67 11.18 e2.205 .225 5.21 5.72 F .060
29、.135 1.52 3.43 H .151 .161 3.84 4.09 5,6 L .312 .500 7.92 12.70 4 L1- .050 - 1.27 3,4 R .495 .525 12.57 13.34 R1.131 .188 3.33 4.78 NOTES: 1. The US government preferred system of measurement is the metric SI system. However, since this item was originally designed using inch-pound units of measurem
30、ent, in the event of conflict between the metric and inch pound units, the inch pound units shall take precedence. 2. Metric equivalents are for general information only. 3. All leads: b applies between L1 and L2 (all leads). b1 applies between L2 and .500 inch (12.70 mm) from the reference plane. D
31、iameter is uncontrolled in L1 and beyond .500 inch (12.70 mm) from the reference plane. 4. Leads having a maximum diameter .043 inch (1.09 mm) measured in gauging plane .054 inch (1.37 mm) + .001 inch (0.03 mm) - .000 inch (0.00 mm) below the seating plane shall be located at true position within di
32、ameter .014 inch (0.36 mm). 5. The product may be measured by direct methods or by gauges. 6. This zone is controlled for automatic handling. The variation in actual diameter within the zone shall not exceed .010 inch (0.25 mm). FIGURE 1. Case outline and terminal connections - Continued. Provided b
33、y IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-89873 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 7 DSCC FORM 2234 APR 97 3.6 Certificate of compliance. A certificate of compliance shall be r
34、equired from a manufacturer in order to be listed as an approved source of supply in MIL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DLA Land and Maritime -VA prior to listing as an approved source of supply shall affirm that the manufacturers product meets the requirements
35、 of MIL-PRF-38535, appendix A and the requirements herein. 3.7 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits delivered to this drawing. 3.8 Notification of change. Notification of change to DLA Land
36、and Maritime -VA shall be required for any change that affects this drawing. 3.9 Verification and review. DLA Land and Maritime, DLA Land and Maritimes agent, and the acquiring activity retain the option to review the manufacturers facility and applicable required documentation. Offshore documentati
37、on shall be made available onshore at the option of the reviewer. 4. VERIFICATION 4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535, appendix A. 4.2 Screening. Screening shall be in accordance with method 5004 of MIL-STD-883, and shall be condu
38、cted on all devices prior to quality conformance inspection. The following additional criteria shall apply: a. Burn-in test, method 1015 of MIL-STD-883. (1) Test condition C. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to
39、 the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1015 of MIL-STD-883. (2) TA= +125C, minimum. b. Interim and final electrical test parameters shall be
40、 as specified in table II herein, except interim electrical parameter tests prior to burn-in are optional at the discretion of the manufacturer. 4.3 Quality conformance inspection. Quality conformance inspection shall be in accordance with method 5005 of MIL-STD-883 including groups A, B, C, and D i
41、nspections. The following additional criteria shall apply. 4.3.1 Group A inspection. a. Tests shall be as specified in table II herein. b. Subgroups 5, 6, 7, 8A, 9, 10, and 11 in table I, method 5005 of MIL-STD-883 shall be omitted. 4.3.2 Groups C and D inspections. a. End-point electrical parameter
42、s shall be as specified in table II herein. b. Steady-state life test conditions, method 1005 of MIL-STD-883. (1) Test condition C. The test circuit shall be maintained by the manufacturer under document revision level control and shall be made available to the preparing or acquiring activity upon r
43、equest. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of MIL-STD-883. (2) TA= +125C, minimum. (3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883. Provided by IHSN
44、ot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-89873 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL A SHEET 8 DSCC FORM 2234 APR 97 TABLE II. Electrical test requirements. MIL-STD-883 test requirements Subgr
45、oups (in accordance with MIL-STD-883, method 5005, table I) Interim electrical parameters (method 5004) 1,2,3 Final electrical test parameters (method 5004) 1*,2,3 Group A test requirements (method 5005) 1,2,3,4,8A* Groups C and D end-point electrical parameters (method 5005) 1 * PDA applies to subg
46、roup 1. * Subgroup 8A, if not tested, shall be guaranteed to the limits specified in table I. 5. PACKAGING 5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A. 6. NOTES 6.1 Intended use. Microcircuits conforming to this drawing are intende
47、d for use for Government microcircuit applications (original equipment), design applications, and logistics purposes. 6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-prepared specification or drawing. 6.3 Configuration control of
48、 SMDs. All proposed changes to existing SMDs will be coordinated with the users of record for the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal. 6.4 Record of users. Military and industrial users shall inform DLA Land and Maritime when a system application requires configuration control and the applicable SMD to that system. DLA Land and Maritime will maintain a record of users and this list will be used for coordination and distribution of changes to the drawings. Users of drawings covering