1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Drawing updated to reflect current requirements. - gt 03-01-10 R. MONNIN B Correct table I, VOMtest; RL= 10 k condition, delete 11 V and substitute 12 V; RL 10 k condition, delete 12 V and substitute 11 V. Update boilerplate paragraphs to current
2、 MIL-PRF-38535 requirements. - ro 10-11-02 C. SAFFLE REV SHET REV SHET REV STATUS REV B B B B B B B B B OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 PMIC N/A PREPARED BY RICK OFFICER DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 http:/www.dscc.dla.mil STANDARD MICROCIRCUIT DRAWING THIS DRAWING IS AVAILABLE F
3、OR USE BY ALL DEPARTMENTS AND AGENCIES OF THE DEPARTMENT OF DEFENSE CHECKED BY RAJESH PITHADIA APPROVED BY RAYMOND MONNIN MICROCIRCUIT, LINEAR, DUAL, OPERATIONAL AMPLIFIER, MONOLITHIC SILICON DRAWING APPROVAL DATE 97-08-26 AMSC N/A REVISION LEVEL B SIZE A CAGE CODE 67268 5962-97603 SHEET 1 OF 9 DSCC
4、 FORM 2233 APR 97 5962-E417-10 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-97603 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This dra
5、wing documents two product assurance class levels consisting of high reliability (device classes Q and M) and space application (device class V). A choice of case outlines and lead finishes are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of Radiation
6、 Hardness Assurance (RHA) levels is reflected in the PIN. 1.2 PIN. The PIN is as shown in the following example: 5962 - 97603 01 Q P A Federal stock class designator RHA designator (see 1.2.1) Device type (see 1.2.2)Device class designatorCase outline (see 1.2.4) Leadfinish (see 1.2.5) / (see 1.2.3)
7、 / Drawing number 1.2.1 RHA designator. Device classes Q and V RHA marked devices meet the MIL-PRF-38535 specified RHA levels and are marked with the appropriate RHA designator. Device class M RHA marked devices meet the MIL-PRF-38535, appendix A specified RHA levels and are marked with the appropri
8、ate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function 01 1558 Dual operational amplifier1.2.3 Device class designator. The device class designator is a single letter id
9、entifying the product assurance level as follows: Device class Device requirements documentation M Vendor self-certification to the requirements for MIL-STD-883 compliant, non-JAN class level B microcircuits in accordance with MIL-PRF-38535, appendix A Q or V Certification and qualification to MIL-P
10、RF-38535 1.2.4 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style P GDIP1-T8 or CDIP2-T8 8 Dual-in-line 2 CQCC1-N20 20 Square leadless chip carrier 1.2.5 Lead finish. The lead finish is as specified in
11、MIL-PRF-38535 for device classes Q and V or MIL-PRF-38535, appendix A for device class M. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-97603 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B
12、 SHEET 3 DSCC FORM 2234 APR 97 1.3 Absolute maximum ratings. 1/ 2/ Positive supply voltage (+VCC) . +22 V Negative supply voltage (-VCC) -22 V Differential input voltage . 30 V 3/ Input voltage at either input (VIN) 15 V 4/ Duration of output short circuit Unlimited 5/ Continuous total dissipation (
13、PD): Case P . 210 mW 6/ Case 2 . 275 mW 6/ Junction temperature (TJ) . +150C Storage temperature range . -65C to +150C Case 2 temperature for 60 seconds 260C Lead temperature 1.6 mm (1/16 inch) from case P for 60 seconds 300C Thermal resistance, junction-to-case (JC) . See MIL-STD-1835 1.4 Recommend
14、ed operating conditions. Supply voltage (VCC) 5 V to 15 V Ambient operating temperature range (TA) . -55C to +125C 2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified
15、 herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. DEPARTMENT OF DEFENSE SPECIFICATION MIL-PRF-38535 - Integrated Circuits, Manufacturing, General Specification for. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-883 - Test Method Standard Mi
16、crocircuits. MIL-STD-1835 - Interface Standard Electronic Component Case Outlines. DEPARTMENT OF DEFENSE HANDBOOKS MIL-HDBK-103 - List of Standard Microcircuit Drawings. MIL-HDBK-780 - Standard Microcircuit Drawings. (Copies of these documents are available online at https:/assist.daps.dla.mil/quick
17、search/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) _ 1/ Stresses above the absolute maximum rating may cause permanent damage to the device. Extended operation at the maximum levels may degrade performance and affect reliability. 2
18、/ All voltage values, unless otherwise noted, are with respect to the midpoint between +VCCand -VCC. 3/ Differential voltages are at +INPUT with respect -INPUT. 4/ The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less. 5/ The output can b
19、e shorted to ground or either power supply. The unlimited duration of the short circuit applies at (or below) +125C case temperature or 70C free air temperature. 6/ For case P, the derating factor is 8.4 mW/C and for case 2, the derating factor is 11 mW/C. Provided by IHSNot for ResaleNo reproductio
20、n or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-97603 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 4 DSCC FORM 2234 APR 97 2.2 Order of precedence. In the event of a conflict between the text of this drawing and the reference
21、s cited herein, the text of this drawing takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements for device classes Q and V shall be in accor
22、dance with MIL-PRF-38535 and as specified herein or as modified in the device manufacturers Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein. The individual item requirements for device class M shall be in accordance with M
23、IL-PRF-38535, appendix A for non-JAN class level B devices and as specified herein. 3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified in MIL-PRF-38535 and herein for device classes Q and V or MIL-PRF-38535, appendix A and herei
24、n for device class M. 3.2.1 Case outlines. The case outlines shall be in accordance with 1.2.4 herein. 3.2.2 Terminal connections. The terminal connections shall be as specified on figure 1. 3.3 Electrical performance characteristics and postirradiation parameter limits. Unless otherwise specified h
25、erein, the electrical performance characteristics and postirradiation parameter limits are as specified in table I and shall apply over the full ambient operating temperature range. 3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The e
26、lectrical tests for each subgroup are defined in table I. 3.5 Marking. The part shall be marked with the PIN listed in 1.2 herein. In addition, the manufacturers PIN may also be marked. For packages where marking of the entire SMD PIN is not feasible due to space limitations, the manufacturer has th
27、e option of not marking the “5962-“ on the device. For RHA product using this option, the RHA designator shall still be marked. Marking for device classes Q and V shall be in accordance with MIL-PRF-38535. Marking for device class M shall be in accordance with MIL-PRF-38535, appendix A. 3.5.1 Certif
28、ication/compliance mark. The certification mark for device classes Q and V shall be a “QML“ or “Q“ as required in MIL-PRF-38535. The compliance mark for device class M shall be a “C“ as required in MIL-PRF-38535, appendix A. 3.6 Certificate of compliance. For device classes Q and V, a certificate of
29、 compliance shall be required from a QML-38535 listed manufacturer in order to supply to the requirements of this drawing (see 6.6.1 herein). For device class M, a certificate of compliance shall be required from a manufacturer in order to be listed as an approved source of supply in MIL-HDBK-103 (s
30、ee 6.6.2 herein). The certificate of compliance submitted to DLA Land and Maritime-VA prior to listing as an approved source of supply for this drawing shall affirm that the manufacturers product meets, for device classes Q and V, the requirements of MIL-PRF-38535 and herein or for device class M, t
31、he requirements of MIL-PRF-38535, appendix A and herein. 3.7 Certificate of conformance. A certificate of conformance as required for device classes Q and V in MIL-PRF-38535 or for device class M in MIL-PRF-38535, appendix A shall be provided with each lot of microcircuits delivered to this drawing.
32、 3.8 Notification of change for device class M. For device class M, notification to DLA Land and Maritime -VA of change of product (see 6.2 herein) involving devices acquired to this drawing is required for any change that affects this drawing. 3.9 Verification and review for device class M. For dev
33、ice class M, DLA Land and Maritime, DLA Land and Maritimes agent, and the acquiring activity retain the option to review the manufacturers facility and applicable required documentation. Offshore documentation shall be made available onshore at the option of the reviewer. 3.10 Microcircuit group ass
34、ignment for device class M. Device class M devices covered by this drawing shall be in microcircuit group number 49 (see MIL-PRF-38535, appendix A). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-97603 DLA L
35、AND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 5 DSCC FORM 2234 APR 97 TABLE I. Electrical performance characteristics. Test Symbol Conditions 1/ -55C TA+125C VCC= 15 V Group A subgroups Device type Limits Unit unless otherwise specified Min Max Input offset voltage VIOVO= 0 V 1 0
36、1 5 mV 2,3 6 Input offset current IIOVO= 0 V 1 01 200 nA 2,3 500Input bias current IIBVO= 0 V 1 01 500 nA 2,3 1500 Common mode input voltage range VICR1,2,3 01 12 V Maximum peak output voltage swing VOM RL= 10 k 1 01 12 V RL 10 k 2,3 11 RL= 2 k 1 10 RL 2 k 2,3 10 Large signal differential voltage am
37、plification AVDRL 2 k, VO= 10 V 4 01 50 V/mV 5,6 25 Input resistance RIN2/ 4 01 0.3 M Common mode rejection ratio CMRR VIC= VICRmin, VO= 0 V 4,5,6 01 70 dB Supply voltage sensitivity ( VIO/ VCC) kSVSVCC= 9 V to 15 V, VO= 0 V 4,5,6 01 150 V/V Short circuit output current IOS1 01 40 mA Supply current
38、ICCVO= 0 V, no load 1 01 5 mA (both amplifiers) 2,3 6.6 Power dissipation PDVO= 0 V, no load 1 01 150 mV (both amplifier) 2,3 200 1/ Unless otherwise specified, all characteristics are specified under open loop operating conditions with zero common mode input voltage. 2/ This parameter is not produc
39、tion tested. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-97603 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 6 DSCC FORM 2234 APR 97 Device type 01 Case outlines P 2 Terminal numb
40、er Terminal symbol 1 OUTPUT 1 NC 2 -INPUT 1 OUTPUT 1 3 +INPUT 1 NC 4 -VCCNC 5 +INPUT 2 -INPUT 1 6 -INPUT 2 NC 7 OUTPUT 2 +INPUT 1 8 +VCCNC 9 - NC 10 - -VCC11 - NC 12 - +INPUT 2 13 - NC 14 - NC 15 - -INPUT 216 - NC 17 - OUTPUT 2 18 - NC 19 - NC 20 - +VCCNC = No connection FIGURE 1. Terminal connectio
41、ns. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-97603 DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 REVISION LEVEL B SHEET 7 DSCC FORM 2234 APR 97 4. VERIFICATION 4.1 Sampling and inspection. For device
42、 classes Q and V, sampling and inspection procedures shall be in accordance with MIL-PRF-38535 or as modified in the device manufacturers Quality Management (QM) plan. The modification in the QM plan shall not affect the form, fit, or function as described herein. For device class M, sampling and in
43、spection procedures shall be in accordance with MIL-PRF-38535, appendix A. 4.2 Screening. For device classes Q and V, screening shall be in accordance with MIL-PRF-38535, and shall be conducted on all devices prior to qualification and technology conformance inspection. For device class M, screening
44、 shall be in accordance with method 5004 of MIL-STD-883, and shall be conducted on all devices prior to quality conformance inspection. 4.2.1 Additional criteria for device class M. a. Burn-in test, method 1015 of MIL-STD-883. (1) Test condition B or D. The test circuit shall be maintained by the ma
45、nufacturer under document revision level control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1015 of MIL-STD-883. (
46、2) TA= +125C, minimum. b. Interim and final electrical test parameters shall be as specified in table II herein. 4.2.2 Additional criteria for device classes Q and V. a. The burn-in test duration, test condition and test temperature, or approved alternatives shall be as specified in the device manuf
47、acturers QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained under document revision level control of the device manufacturers Technology Review Board (TRB) in accordance with MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon req
48、uest. The test circuit shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1015 of MIL-STD-883. b. Interim and final electrical test parameters shall be as specified in table II herein. c. Additional screening for device class V beyond the requirements of device class Q shall be as specified in MIL-PRF-38535, appendix B. 4.3 Qualification inspection for device classes Q and V. Qualification inspection for device classes Q and V shall be in a
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有