1、EIA STANDARDTP-15C Contact Strength Test Procedure for Electrical Connectors EIA-364-15C (Revision of EIA-364-15B) August 2016 Electronic Components Industry Association EIA-364-15CANSI/EIA-364-15C-2016 Approved: August 26, 2016NOTICEEIA Engineering Standards and Publications are designed to serve t
2、he public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standard
3、s and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude their voluntary use by those other than ECIA members, whe
4、ther the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liability to any patent owner, nor does it assume any obl
5、igation whatever to parties adopting the Standard or Publication. This standard is based upon the major technical content of International Electrotechnical Commission standard 60512-16-3 (was IEC 512-8, test 16c), Contact-bending strength, 2008. It conforms in all essential respects this IEC standar
6、d. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to determine the applicability of regulatory limitations
7、before its use. (From Standards Proposal No. 5357, formulated under the cognizance of the CE-2.0 Committee on EIA National Connector and Sockets Standards. Published by Electronic Components Industry Association 2016 EIA Standards & Technology Department 2214 Rock Hill Road, Suite 265 Herndon, VA 20
8、170PLEASE ! DONT VIOLATE THE LAW!This document is copyrighted by the ECIA and may not be reproduced without permission. Organizations may obtain permission to reproduce a limited number of copies through entering into a license agreement. For information, contact: IHS Markit 15 Inverness Way East En
9、glewood, CO 80112-5704 or call USA and Canada (1-877-413-5186), International (303-397-7956) i CONTENTS Clause Page 1 Introduction . 1 1.1 Scope . 1 2 Test resources 1 2.1 Test equipment 1 3 Test specimen 1 3.1 Description 1 3.2 Preparation 1 4 Test procedure . 2 4.1 Test load 2 4.2 Permanent set 2
10、5 Details to be specified . 2 6 Test documentation . 2 Figure 1 Mounting fixture . 3 ii (This page left blank) EIA-364-15C Page 1 TEST PROCEDURE No. 15C CONTACT STRENGTH TEST PROCEDURE FOR ELECTRICAL CONNECTORS AND SOCKETS (From EIA Standards Proposal No. 5357, formulated under the cognizance of the
11、 EIA CE-2.0 Committee on National Connector Standards, and previously published in EIA-364-15B.) 1 Introduction 1.1 Scope This standard establishes a test method to determine the exposed contact (pin or socket) strength for contact sizes 20 and smaller when subjected to a defined bending stress (or
12、moment). 2 Test resources 2.1 Test equipment Test equipment shall consist of a displacement meter and a suitable means of positively securing the exposed contact. 2.1.1 Displacement meter A displacement meter (i.e. dial indicator) having an accuracy of 5% shall be used to measure permanent set. 2.1.
13、2 Mounting fixture A fixture that positively secures the exposed contact, in the area indicated in figure 1, shall be used. 3 Test specimen 3.1 Description A test specimen shall consist of an exposed contact, unless than otherwise specified in the referencing document. 3.2 Preparation The test speci
14、men shall be secured in a suitable mounting fixture as indicated in figure 1, unless otherwise specified in the referencing document. EIA-364-15C Page 2 4 Test procedure 4.1 Test load The test load shall be applied as indicated in figure 1, with the rate of travel of the loading mechanism not exceed
15、ing 25.4 millimeters / minute (1.0 inch / minute). The load shall be maintained for 60 seconds +15 seconds, -0 seconds. 4.2 Permanent set The permanent set shall be the difference between the initial position of the contact before the load is applied, and the final position of the contact after pres
16、cribed load has been removed. The degree of permanent set shall not exceed 0.13 millimeters (0.005 inch) at the 0.8 L load point unless otherwise specified in the referencing document. 5 Details to be specified The following details shall be specified in the referencing document: 5.1 Number of speci
17、mens to be tested 5.2 Test specimen description 5.3 Special preparations or conditioning, if required 5.4 Minimum moment required per individual contact size, see figure 1 5.5 Duration of test load application, if other than specified in 4.1 5.6 Maximum permissible permanent set, if other than speci
18、fied in 4.2 6 Test documentation Documentation shall contain the details specified in clause 5, with any exceptions, and the following: 6.1 Title of test 6.2 Specimen description, including fixturing 6.3 Test equipment used, and date of last and next calibration 6.4 Test and procedure 6.5 Values and
19、 observations 6.6 Name of operator and start/finish date(s) of test EIA-364-15C Page 3 Pin Socket Contact size Moment 20 0.060 Newton meter (0.53 pound inch) 22 0.025 Newton meter (0.22 pound inch) 23 0.018 Newton meter (0.16 pound inch) 24 0.015 Newton meter (0.13 pound inch) NOTE 1) Load = Moment
20、/ 0.8L Figure 1 Mounting fixtureECIA Document Improvement Proposal If in the review or use of this document, a potential change is made evident for safety, health or technical reasons, please fill in the appropriate information below and mail or FAX to: Electronic Components Industry Association EIA
21、 Standards & Technology Department 2214 Rock Hill Rd., Suite 265 Herndon, VA 20170 FAX: (571-323-0245) Document No.: Document Title: Submitters Name: Telephone No.: FAX No.: e-mail: Address: Urgency of Change: Immediate: At next revision: Problem Area: a. Clause Number and /or Drawing: b. Recommende
22、d Changes: c. Reason/Rationale for Recommendation: Additional Remarks: Signature: Date: FOR ECIA USE ONLYResponsible Committee: Chairman: Date comments forwarded to Committee Chairman: Revision History Revision letter Project number Publication date Additions, changes and deletions- SP-1436 March 19
23、84 Initial published as EIA RS-364-15 A SP-5110 March 2006 B SP-5349 June 2015 Revised paragraph 6.6 Revise Figure 1 to change the 60 to 60 maximum to correct error. Maximum was eliminated in some published copies Revise Figure 1 to add units to the 0.127 (0.005) radius dimensions C SP-5357 Delete t
24、he words pin contacts in paragraph 1.1 and replace with exposed contact (pin or socket) Delete the word pin from in front of the word contact in paragraphs 1.1, 2.1.2 and 3.1 and replace with exposed Revise Figure 1 to show a socket contact, and change Pin size to Contact size in table heading Electronic Components Industry Association 2214 Rock Hill Road, Suite 265 * Herndon, VA 20170 * tel 571-323-0294 * fax 571-323-0245 www.ecianow.org