1、 EIA STANDARD Fixed Resistors for Use in Electronic Equipment Part 9: Sectional Specification: Fixed Surface Mount Resistor Networks with Individually Measurable Resistors EIA-60115-9 (IEC 60115-9:2003, IDT) October 2014 ANSI/EIA-60115-9-2014 Approved: October 6, 2014 EIA-60115-9NOTICE EIA Engineeri
2、ng Standards and Publications are designed to serve the public interest through eliminating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper produc
3、t for his particular need. Existence of such Standards and Publications shall not in any respect preclude any member or nonmember of ECIA from manufacturing or selling products not conforming to such Standards and Publications, nor shall the existence of such Standards and Publications preclude thei
4、r voluntary use by those other than ECIA members, whether the standard is to be used either domestically or internationally. Standards and Publications are adopted by ECIA in accordance with the American National Standards Institute (ANSI) patent policy. By such action, ECIA does not assume any liab
5、ility to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard or Publication. This EIA Standard is identical (IDT) with the International Standard IEC Publication 60115-9:2003: Fixed Resistors for Use in Electronic Equipment Part 9: Sectional Specification: F
6、ixed Surface Mount Resistor Networks with Individually Measurable Resistors. This document is the EIA Standard EIA-60115-9: 2014: Fixed Resistors for Use in Electronic Equipment Part 9: Sectional Specification: Fixed Surface Mount Resistor Networks with Individually Measurable Resistors. The text, f
7、igures and tables of IEC 60115-9:2003 are used in this Standard with the consent of the IEC and the American National Standards Institute (ANSI). The IEC copyrighted material has been reproduced with permission from ANSI. The IEC Foreword and Introduction are not part of the requirements of this sta
8、ndard but are included for information purposes only. This Standard does not purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this Standard to establish appropriate safety and health practices and to det
9、ermine the applicability of regulatory limitations before its use. (From Standards Proposal No. 5313, formulated under the cognizance of the Steering Committee for Passive Electronic Components Standards (S-1). Published by Electronic Components Industry Association 2014 Standards any IEC National C
10、ommittee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in
11、 accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from a
12、ll interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held
13、responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regional publications. Any dive
14、rgence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity with an IEC Publication.
15、 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any personal injury, property da
16、mage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative references cited in this pu
17、blication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible for identifying any or all
18、 such patent rights. International Standard IEC 60115-9 has been prepared by IEC technical committee 40: Capacitors and resistors for electronic equipment. The text of this standard is based on the following documents: FDIS Report on voting 40/1344/FDIS 40/1366/RVD Full information on the voting for
19、 the approval of this standard can be found in the report on voting indicated in the above table. This publication has been drafted in accordance with the ISO/IEC Directives, Part 2. EIA-60115-9 Page 2 The committee has decided that the contents of this publication will remain unchanged until 2008.
20、At this date, the publication will be reconfirmed; withdrawn; replaced by a revised edition, or amended. A bilingual edition of this standard may be issued at a later date. EIA-60115-9 Page 3 FIXED RESISTORS FOR USE IN ELECTRONIC EQUIPMENT Part 9: Sectional specification: Fixed surface mount resisto
21、r networks with individually measurable resistors 1 General 1.1 Scope This part of IEC 60115 is applicable to fixed surface mount resistor networks with individually measurable resistors for use in electronic equipment. 1.2 Object The object of this standard is to prescribe preferred ratings and cha
22、racteristics and to select from IEC 60115-1, the appropriate Quality Assessment procedures, tests and measuring methods and to give general performance requirements for this type of resistor. Test severities and requirements prescribed in detail specifications referring to this sectional specificati
23、on must be of equal or higher performance level, because lower performance levels are not permitted. 1.3 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the l
24、atest edition of the referenced document (including any amendments) applies. IEC 60063:1963, Preferred number series for resistors and capacitors Amendment 1 (1967) Amendment 2 (1977) IEC 60068-1: Environmental testing Part 1: General and guidance IEC 60068-2-1: Environmental testing Part 2: Tests.
25、Tests A: Cold IEC 60068-2-2: Environmental testing Part 2: Tests. Tests B: Dry heat IEC 60115-1:1999, Fixed resistors for use in electronic equipment Part 1: Generic specification 1.4 Information to be given in a detail specification Detail specifications shall be derived from the relevant blank det
26、ail specification. Detail specifications shall not specify requirements inferior to those of the generic, sectional specification or blank detail specification. When more severe requirements are included, they shall be listed in 1.8 of the detail specification and indicated in the test schedules, fo
27、r example by an asterisk. EIA-60115-9 Page 4 The following information shall be given in each detail specification and the values quoted shall preferably be selected from those given in the appropriate clause of this sectional specification. 1.4.1 Outline drawing and dimensions There shall be an ill
28、ustration of the surface mount resistor network as an aid to easy recognition and for comparison of the surface mount resistor network with others. Dimensions and their associated tolerances, which affect interchangeability and mounting, shall be given in the detail specification. All dimensions sha
29、ll be stated in millimetres. Normally the numerical values shall be given for the length, width and thickness of the body. Schematic diagrams and pin identifications shall be given in the detail specification. Those are prescribed in Annex A. Configurations of terminations shall be given in the deta
30、il specification. Those are prescribed in Annex B. When the outline drawing is other than described above, the detail specification shall state such dimensional information as will adequately describe the surface mount resistor network. 1.4.2 Mounting The detail specification shall give guidance on
31、methods of mounting for normal use. Mounting for test and measurement purposes (when required) shall be in accordance with 4.31 of IEC 60115-1. 1.4.3 Style (2.2.2 of IEC 60115-1) The styles given in Table 1 are preferred. All dimensions are in mm. Table 1 Style and outline dimensions Dimensions in m
32、m Code Length L Width W Thickness T Diagrama)Construction of terminalsa)1005X2 1 0,1 1 0,1 0,35 0,1 A Convex 1005X4 2 0,1 1 0,1 0,4 0,15 A Convex Concave 1608X2 1,6 0,2 1,6 0,2 0,55 0,15 A Convex Concave 1608X4 3,2 0,2 1,6 0,2 0,55 0,15 A Convex Concave 3216X4 5,08 0,2 3,1 0,2 0,55 0,15 A Convex Con
33、cave 3216 3,2 0,2 1,6 0,2 0,5 0,15 B, C Convex 4021 4 0,2 2,1 0,2 0,6 0,15 D Concave 6431 6,4 0,2 3,1 0,2 0,6 0,15 B, C Convex Concave a)Diagrams are shown in Annex A. Constructions of terminals are shown in Annex B. EIA-60115-9 Page 5 1.4.4 Ratings and characteristics The ratings and characteristic
34、s shall be in accordance with the relevant clauses of this specification together with the following: Rated resistance range See 2.2.1. The preferred values are those of the E-series of IEC 60063. NOTE When products approved to the detail specification have different ranges, the following statement
35、should be added: “The range of values available in each style is given in the qualified products list”. 1.4.5 Marking The detail specification shall specify the content of the marking on the surface mount resistor network and on the package. Surface mount resistor networks are generally not marked o
36、n the body. If some marking can be applied, the surface mount resistor network shall be clearly marked with the rated resistance and as many of the remaining items in 2.4 of IEC 60115-1 as possible. All items shall be marked on the package. Deviations from the above mentioned requirements shall be s
37、pecifically stated. 2 Preferred ratings, characteristics and test severities 2.1 Preferred ratings and characteristics The values given in detail specifications shall preferably be selected from the following: 2.1.1 Preferred climatic categories The surface mount resistor networks covered by this sp
38、ecification are classified into climatic categories according to the general rules given in IEC 60068-1. The lower and upper category temperature and the duration of the damp heat, steady state shall be chosen from the following: Lower category temperature: 55 C, 40 C, 25 C and 10 C. Upper category
39、temperature: +85 C, +100 C, +125 C and +155 C. Duration of the damp heat, steady state test: 4, 10, 21 and 56 days. The severities for the cold and dry heat tests are the lower and upper category temperatures respectively. Because of the construction of some surface mount resistor networks these tem
40、peratures will occur between two of the preferred temperatures given in IEC 60068-2-1 and IEC 60068-2-2. In this event, the nearest preferred temperature within the actual temperature range of the surface mount resistor network shall be chosen for this severity. 2.1.2 Temperature coefficients and te
41、mperature characteristics of resistance The preferred limits of change in resistance for the temperature characteristics of resistance test are given in Table 2. EIA-60115-9 Page 6 Each line in the table gives the preferred temperature coefficient and corresponding temperature characteristic for 20
42、C to 70 C and limits of change in resistance for the measurement of the temperature characteristic of resistance (see 4.8 of IEC 60115-1) on the basis of category temperature ranges of 2.1.1 of this sectional specification. Table 2 Temperature coefficients and temperature characteristics of resistan
43、ce Temper-ature coeffi-cient Temper-ature charac-teristic 20/70 C Temperature characteristic of resistance (limits of percentage change in resistance) Reference temperature /lower category temperature Reference temperature /upper category temperature 106/K % +20/55 +20/40 +20/25 +20/10 +20/+85 +20/+
44、100 +20/+125 +20/+155 500 2,5 3,75 3 2,25 1,500 3,25 4 5,25 6,75 250 1,25 1,88 1,5 1,13 0,750 1,62 2 2,62 3,38 100 0,5 0,75 0,6 0,45 0,300 0,65 0,8 1,05 1,35 50 0,25 0,375 0,3 0,23 0,150 0,325 0,4 0,525 0,675 25 0,125 0,188 0,15 0,113 0,075 0,162 0,2 0,262 0,338 15 0,075 0,113 0,09 0,068 0,045 0,098
45、 0,12 0,158 0,203 10 0,05 0,075 0,06 0,045 0,030 0,065 0,08 0,105 0,135 NOTE 1 Resistors having an upper category temperature of +85 C need not be measured between 20 C and 70 C. NOTE 2 If measurements are required at additional temperatures, these shall be specified in the detail specification. 2.1
46、.3 Limits for change in resistance For each stability class the preferred limits for change in resistance for each of the tests listed in the heading of Table 3 are as indicated. Table 3 Limits for change in resistance Stability class in % Long-term tests 4.23 Climatic sequence 4.24 Damp heat, stead
47、y state 4.25.1 Endurance at 70 C 4.25.3 Endurance at upper category temperature Short-term tests 4.13 Overload 4.18 Resistance to soldering heat 4.19 Rapid change of temperature 4.32 Shear 4.33 Substrate bending test 5 3 2 1 0,5 0,25 0,1 (5 % +0,1 ) (3 % +0,1 ) (2 % +0,1 ) (1 % +0,05 ) (0,5 % +0,05
48、) (0,25 % +0,05 ) (0,1 % +0,01 ) (1 % +0,05 ) (0,5 % +0,05 ) (0,5 % +0,05 ) (0,25 % +0,05 ) (0,1 % +0,01 ) (0,05 % +0,01 ) (0,02 % +0,01 ) NOTE The clause numbers in the heading refer to IEC 60115-1. EIA-60115-9 Page 7 2.2 Preferred values of ratings 2.2.1 Rated resistance See 2.2.6 of IEC 60115-1.
49、2.2.2 Tolerances on rated resistance The preferred tolerances on rated resistance are: 5 %; 2 %; 1 %; 0,5 %; 0,25 % and 0,1 %. 2.2.3 Rated dissipation (in the mounted state) The preferred values of rated dissipation, at 70 C, are: For the network: 0,125 W; 0,25 W and 0,5 W. For the resistor element: 0,03 W; 0,05 W; 0,063 W; 0,1 W and 0,125 W. The detail specification shall prescribe the appli