1、BSI Standards PublicationBS EN 124-2:2015Gully tops and manhole topsfor vehicular and pedestrianareasPart 2: Gully tops and manhole tops madeof cast ironBS EN 124-2:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 124-2:2015.Together with BS EN 124-1:2015, B
2、S EN 124-3:2015, BS EN 124-4:2015,BS EN 124-5:2015 and BS EN 124-6:2015, it supersedes BS EN 124:1994which is withdrawn.BSI, as a member of CEN, is obliged to publish EN 124-2 as a BritishStandard. However, attention is drawn to the fact that during thedevelopment of this European Standard, the UK c
3、ommittee votedagainst its approval as a European Standard.In the opinion of the UK committee, the lack of testing requirements forthe assessment of deflection under load for ductile iron materials couldresult in an inconsistent application of performance requirements acrossvarious elastic materials.
4、 In addition, the reasoning behind the responserelates to the application of the Construction Products Regulations inrespect to subclause 7.3.2.6, as a result of the AVCP Level 1 requirement.The UK participation in its preparation was entrusted by TechnicalCommittee B/505, Wastewater engineering, to
5、 Subcommittee B/505/4,“Manhole Covers, Surface Boxes And Other Road Fittings”.A list of organizations represented on this subcommittee can beobtained on request to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its corr
6、ect application. The British Standards Institution 2015.Published by BSI Standards Limited 2015ISBN 978 0 580 79323 3ICS 93.080.30Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strateg
7、y Committee on 31 July 2015.Amendments/corrigenda issued since publicationDate Text affectedEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORM EN 124-2 June 2015 ICS 93.080.30 Supersedes EN 124:1994English Version Gully tops and manhole tops for vehicular and pedestrian areas -Part 2: Gully tops and ma
8、nhole tops made of cast iron Dispositifs de couronnement et de fermeture pour les zonesde circulation utilises par les pitons et les vhicules -Partie 2: Dispositifs de couronnement et de fermeture enfonte Aufstze und Abdeckungen fr Verkehrsflchen - Teil 2:Aufstze und Abdeckungen aus Gusseisen This E
9、uropean Standard was approved by CEN on 12 March 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references c
10、oncerning such nationalstandards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member i
11、nto its own language and notified to the CEN-CENELEC Management Centre has the samestatus as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,Finland, Former Yugoslav Republic of Macedonia, France, G
12、ermany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania,Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and UnitedKingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE F
13、R NORMUNGCEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members. Ref. No. EN 124-2:2015 EBS EN 124-2:2015EN 124-2:2015 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references
14、 4 3 Terms and definitions .5 4 Materials .5 4.1 General 5 4.2 Coating materials .5 4.3 Cover fillings 5 5 Requirements .6 5.1 Design and performance requirements .6 5.2 Covers with fillings 7 5.3 Material-specific characteristics for gully tops and manhole tops made of cast iron .7 5.3.1 Reaction t
15、o fire .7 5.3.2 Durability 7 5.3.3 Dangerous substances .8 6 Testing 8 7 Assessment and verification of constancy of performance - AVCP 8 7.1 General 8 7.2 Type testing 9 7.2.1 General 9 7.2.2 Test samples, testing and compliance criteria .9 7.2.3 Test reports . 11 7.2.4 Shared other party results .
16、 11 7.3 Factory production control (FPC) . 12 7.3.1 General . 12 7.3.2 Requirements 12 7.3.3 Product specific requirements 17 7.3.4 Initial inspection of factory and of FPC 18 7.3.5 Continuous surveillance of FPC . 18 7.3.6 Procedure for modifications 18 8 Designation . 18 9 Marking 20 Annex ZA (inf
17、ormative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation . 22 ZA.1 Scope and relevant characteristics 22 ZA.2 Procedures for AVCP of gully tops and manhole tops made of cast iron 24 ZA.3 CE marking and labelling . 28 Bibliography . 32 BS EN 124
18、-2:2015EN 124-2:2015 (E) 2 Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Terms and definitions .5 4 Materials .5 4.1 General 5 4.2 Coating materials .5 4.3 Cover fillings 5 5 Requirements .6 5.1 Design and performance requirements .6 5.2 Covers with fillings 7 5.3 Material-specific c
19、haracteristics for gully tops and manhole tops made of cast iron .7 5.3.1 Reaction to fire .7 5.3.2 Durability 7 5.3.3 Dangerous substances .8 6 Testing 8 7 Assessment and verification of constancy of performance - AVCP 8 7.1 General 8 7.2 Type testing 9 7.2.1 General 9 7.2.2 Test samples, testing a
20、nd compliance criteria .9 7.2.3 Test reports . 11 7.2.4 Shared other party results . 11 7.3 Factory production control (FPC) . 12 7.3.1 General . 12 7.3.2 Requirements 12 7.3.3 Product specific requirements 17 7.3.4 Initial inspection of factory and of FPC 18 7.3.5 Continuous surveillance of FPC . 1
21、8 7.3.6 Procedure for modifications 18 8 Designation . 18 9 Marking 20 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Construction Products Regulation . 22 ZA.1 Scope and relevant characteristics 22 ZA.2 Procedures for AVCP of gully tops and manhole tops
22、 made of cast iron 24 ZA.3 CE marking and labelling . 28 Bibliography . 32 BS EN 124-2:2015EN 124-2:2015 (E) 3 Foreword This document (EN 124-2:2015) has been prepared by Technical Committee CEN/TC 165 “Wastewater engineering”, the secretariat of which is held by DIN. This European Standard shall be
23、 given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by December 2015 and conflicting national standards shall be withdrawn at the latest by March 2017. Attention is drawn to the possibility that some of the elements of this document m
24、ay be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. Together with EN 124-1:2015, EN 124-3:2015, EN 124-4:2015, EN 124-5:2015 and EN 124-6:2015, this document supersedes EN 124:1994. This document has been prepared under
25、a mandate given to CEN by the European Commission and the European Free Trade Association, and supports essential requirements of the Regulation (EU) No. 305/2011. For relationship with EU Regulation(s), see informative Annex ZA, which is an integral part of this document. EN 124, Gully tops and man
26、hole tops for vehicular and pedestrian areas, consists of the following parts: Part 1: Definitions, classification, general principles of design, performance requirements and test methods; Part 2: Gully tops and manhole tops made of cast iron; Part 3: Gully tops and manhole tops made of steel or alu
27、minium alloys; Part 4: Gully tops and manhole tops made of steel reinforced concrete; Part 5: Gully tops and manhole tops made of composite materials; Part 6: Gully tops and manhole tops made of polypropylene (PP), polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U). According to the CEN
28、-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungar
29、y, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 124-2:2015EN 124-2:2015 (E) 4 1 Scope This European Standard is applicable to gully tops and manhole
30、tops made of flake graphite cast iron and/or spheroidal graphite cast iron whether in combination with concrete or not, with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation within areas subjected to pedestrian and/or vehicular traf
31、fic. It is applicable to manhole tops and gully tops for use in areas which can only be used by pedestrians and pedal cyclists (at least class A 15), pedestrian areas and comparable areas, car parks or car parking decks (at least class B 125), the area of kerbside channels of roads which, when measu
32、red from the kerb edge, extends a maximum of 0,5 m into the carriageway and a maximum of 0,2 m into the pedestrian area (at least class C 250), carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (at least class D 400), areas imposin
33、g high wheel loads, e.g. docks, aircraft pavements (at least class E 600), areas imposing particularly high wheel loads, e.g. aircraft pavements (class F 900). This European Standard is not applicable in isolation but only in combination with EN 124-1 and gives guidance for combinations of covers/gr
34、ating made of cast iron with frames according to EN 124-3, EN 124-4, EN 124-5 or EN 124-6. This European Standard is not applicable to: cover fillings installed on site, e.g. concrete, paving blocks, etc.; concave gratings for class D 400 installed in carriageways of roads or hard shoulders and conc
35、ave gratings for classes F 900 and E 600; gratings/covers as part of prefabricated drainage channels according to EN 1433; floor and roof gullies in buildings which are specified in EN 1253 (all parts); and surface boxes. 2 Normative references The following documents, in whole or in part, are norma
36、tively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 124-1:2015, Gully tops and manhole tops for vehicular and p
37、edestrian areas Part 1: Definitions, classification, general principles of design, performance requirements and test methods EN 124-3:2015, Gully tops and manhole tops for vehicular and pedestrian areas Part 3: Gully tops and manhole tops made of steel or aluminium alloys EN 124-4:2015, Gully tops a
38、nd manhole tops for vehicular and pedestrian areas Part 4: Gully tops and manhole tops made of steel reinforced concrete BS EN 124-2:2015EN 124-2:2015 (E) 4 1 Scope This European Standard is applicable to gully tops and manhole tops made of flake graphite cast iron and/or spheroidal graphite cast ir
39、on whether in combination with concrete or not, with a clear opening up to and including 1 000 mm for covering gullies, manholes and inspection chambers for installation within areas subjected to pedestrian and/or vehicular traffic. It is applicable to manhole tops and gully tops for use in areas wh
40、ich can only be used by pedestrians and pedal cyclists (at least class A 15), pedestrian areas and comparable areas, car parks or car parking decks (at least class B 125), the area of kerbside channels of roads which, when measured from the kerb edge, extends a maximum of 0,5 m into the carriageway
41、and a maximum of 0,2 m into the pedestrian area (at least class C 250), carriageways of roads (including pedestrian streets), hard shoulders and parking areas, for all types of road vehicles (at least class D 400), areas imposing high wheel loads, e.g. docks, aircraft pavements (at least class E 600
42、), areas imposing particularly high wheel loads, e.g. aircraft pavements (class F 900). This European Standard is not applicable in isolation but only in combination with EN 124-1 and gives guidance for combinations of covers/grating made of cast iron with frames according to EN 124-3, EN 124-4, EN
43、124-5 or EN 124-6. This European Standard is not applicable to: cover fillings installed on site, e.g. concrete, paving blocks, etc.; concave gratings for class D 400 installed in carriageways of roads or hard shoulders and concave gratings for classes F 900 and E 600; gratings/covers as part of pre
44、fabricated drainage channels according to EN 1433; floor and roof gullies in buildings which are specified in EN 1253 (all parts); and surface boxes. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its applica
45、tion. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 124-1:2015, Gully tops and manhole tops for vehicular and pedestrian areas Part 1: Definitions, classification, general principles
46、of design, performance requirements and test methods EN 124-3:2015, Gully tops and manhole tops for vehicular and pedestrian areas Part 3: Gully tops and manhole tops made of steel or aluminium alloys EN 124-4:2015, Gully tops and manhole tops for vehicular and pedestrian areas Part 4: Gully tops an
47、d manhole tops made of steel reinforced concrete BS EN 124-2:2015EN 124-2:2015 (E) 5 EN 124-5:2015, Gully tops and manhole tops for vehicular and pedestrian areas Part 5: Gully tops and manhole tops made of composite materials EN 124-6:2015, Gully tops and manhole tops for vehicular and pedestrian a
48、reas Part 6: Gully tops and manhole tops made of polypropylene (PP), polyethylene (PE) or unplasticized poly(vinyl chloride) (PVC-U) EN 206:2013, Concrete Specification, performance, production and conformity EN 1561, Founding Grey cast irons EN 1563, Founding Spheroidal graphite cast irons 3 Terms
49、and definitions For the purposes of this document, the terms and definitions given in EN 124-1:2015 apply. 4 Materials 4.1 General Manhole tops and gully tops according to this European Standard shall be made from the materials listed below. a) flake graphite cast iron according to EN 1561, b) spheroidal graphite cast iron according to EN 1563, c) one of the materials a) and b) combined with concrete with a minimum compressive strength class of C35/45. Any element made of the materials specified in