1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 12430:2013Thermal insulating productsfor building applications Determination of behaviourunder point loadBS EN 12430:2013 BRITISH STANDARDNational forewordThis British Stan
2、dard is the UK implementation of EN 12430:2013. Itsupersedes BS EN 12430:1998 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee B/540, Energy performance of materials components andbuildings.A list of organizations represented on this committee can beobta
3、ined on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correct application. The British Standards Institution 2013. Published by BSI Standards Limited 2013 ISBN 978 0 580 78052 3 ICS 91.100.60 Compliance
4、with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 April 2013. Amendments issued since publicationDate Text affectedBS EN 12430:2013EUROPEAN STANDARD NORME EUROPENNE EUROPI
5、SCHE NORM EN 12430 March 2013 ICS 91.100.60 Supersedes EN 12430:1998English Version Thermal insulating products for building applications - Determination of behaviour under point load Produits isolants thermiques destins aux applications du btiment - Dtermination du comportement sous charge ponctuel
6、le Wrmedmmstoffe fr das Bauwesen - Bestimmung des Verhaltens unter Punktlast This European Standard was approved by CEN on 15 December 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a nati
7、onal standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A ver
8、sion in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus,
9、Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom
10、. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12430:2013: EBS EN 124
11、30:2013EN 12430:2013 (E) 2 Contents Page Foreword . 3 1 Scope 5 2 Normative references . 5 3 Terms and definitions 5 4 Principle 5 5 Apparatus . 5 6 Test specimens 7 7 Procedure . 8 8 Calculation and expression of results 9 9 Accuracy of measurement . 10 10 Test report 10 Annex A (normative) Modific
12、ations to the general test method for cellular glass products . 11 BS EN 12430:2013EN 12430:2013 (E) 3 Foreword This document (EN 12430:2013) has been prepared by Technical Committee CEN/TC 88 “Thermal insulating materials and products”, the secretariat of which is held by DIN. This European Standar
13、d shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2013, and conflicting national standards shall be withdrawn at the latest by September 2013. Attention is drawn to the possibility that some of the elements of
14、 this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12430:1998. The revision of this standard contains no major changes, only minor corrections and clarifications of an editori
15、al nature. This European Standard is one of a series of standards which specify test methods for determining dimensions and properties of thermal insulating materials and products. It supports a series of product standards for thermal insulating materials and products which derive from the Council D
16、irective of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products (Directive 89/106/EEC) through the consideration of the essential requirements. This European Standard has been drafted for applications in buil
17、dings but it may also be used in other areas where it is relevant. This European test standard is one of the following group of interrelated standards on test methods for determining dimensions and properties of thermal insulation materials and products, all of which fall within the scope of CEN/TC
18、88: EN 822, Thermal insulating products for building applications Determination of length and width EN 823, Thermal insulating products for building applications Determination of thickness EN 824, Thermal insulating products for building applications Determination of squareness EN 825, Thermal insul
19、ating products for building applications Determination of flatness EN 826, Thermal insulating products for building applications Determination of compression behaviour EN 1602, Thermal insulating products for building applications Determination of the apparent density EN 1603, Thermal insulating pro
20、ducts for building applications Determination of dimensional stability under constant normal laboratory conditions (23 C/50 % relative humidity) EN 1604, Thermal insulating products for building applications Determination of dimensional stability under specified temperature and humidity conditions E
21、N 1605, Thermal insulating products for building applications Determination of deformation under specified compressive load and temperature conditions EN 1606, Thermal insulating products for building applications Determination of compressive creep BS EN 12430:2013EN 12430:2013 (E) 4 EN 1607, Therma
22、l insulating products for building applications Determination of tensile strength perpendicular to faces EN 1608, Thermal insulating products for building applications Determination of tensile strength parallel to faces EN 1609, Thermal insulating products for building applications Determination of
23、short-term water absorption by partial immersion EN 12085, Thermal insulating products for building applications Determination of linear dimensions of test specimens EN 12086, Thermal insulating products for building applications Determination of water vapour transmission properties EN 12087, Therma
24、l insulating products for building applications Determination of long-term water absorption by immersion EN 12088, Thermal insulating products for building applications Determination of long-term water absorption by diffusion EN 12089, Thermal insulating products for building applications Determinat
25、ion of bending behaviour EN 12090, Thermal insulating products for building applications Determination of shear behaviour EN 12091, Thermal insulating products for building applications Determination of freeze-thaw resistance EN 12429, Thermal insulating products for building applications Conditioni
26、ng to moisture equilibrium under specified temperature and humidity conditions EN 12430, Thermal insulating products for building applications Determination of behaviour under point load EN 12431, Thermal insulating products for building applications Determination of thickness for floating floor ins
27、ulating products EN 13793, Thermal insulating products for building applications Determination of behaviour under cyclic loading EN 13820, Thermal insulating materials for building applications Determination of organic content According to the CEN/CENELEC Internal Regulations, the national standards
28、 organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxemb
29、ourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 12430:2013EN 12430:2013 (E) 5 1 Scope This European Standard specifies equipment and procedures for determining the behaviour of products under a force ap
30、plied to a small area of a test specimen at a given speed. It is applicable to thermal insulating products. This European Standard can be used to determine whether the products have sufficient strength to withstand forces applied directly to them either during installation or during application, mai
31、nly caused by pedestrian traffic. NOTE The test methods given in the main body of the standard and in Annex A are reported and interpreted in different ways. The similarities that exist between the methods are not sufficient to permit reasonable comparisons to be made. 2 Normative references The fol
32、lowing documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12085, Ther
33、mal insulating products for building applications Determination of linear dimensions of test specimens ISO 5725-2, Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method 3 T
34、erms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 point load compressive force applied to a test specimen by a circular indentor with a circular cross section of 50 cm2(diameter 79,8 mm) 3.2 critical point point on the force-deformation curve, whe
35、re a straight line, forming a tangent to the curve, separates from the curve Note 1 to entry: See Figure 4a). 4 Principle A point load is applied with an indentor at a given speed in an axial direction perpendicular to the major faces of a squarely cut square test specimen and the compressive force
36、at the critical point and/or the force for a given deformation is calculated. 5 Apparatus 5.1 Compression testing machine, appropriate to the range of force and displacement involved and having one rigid, polished, fixed or vertically movable square or circular plane plate of which the length of one
37、 side (or the diameter) is at least as large as the length (or the diagonal length) of the test specimen (see Figure 1). 5.2 Cylindrical indentor, steel, having a diameter of (79,8 0,1) mm, connected to a vertically movable or fixed support. BS EN 12430:2013EN 12430:2013 (E) 6 If appropriate, the in
38、dentor shall be connected to the compression machine through a centrally positioned ball joint to ensure that only axial force is applied to the relevant area of the test specimen. The indentor or the supporting plate shall be capable of moving at a constant speed in accordance with 7.2 (see Figures
39、 2 and 3). Key 1 connection to the testing machine 2 indentor 3 test specimen 4 supporting plate Figure 1 Test setup BS EN 12430:2013EN 12430:2013 (E) 7 Dimensions in millimetres Key 1 cylindrical indentor 2 test specimen Figure 2 Test specimen Figure 3 Cylindrical indentor 5.3 Displacement- measuri
40、ng device, capable of continuous measurement of the displacement of the indenter or the movable plate, permitting a reading to 5 % or 0,1 mm, whichever is the smaller (see 5.1.1). 5.4 Force-measuring sensor, fitted to the machine plate or the indenter, to measure the force produced by the reaction o
41、f the test specimen upon the plate and the indenter. This sensor shall be such that its own deformation during the course of the measuring operation is negligible compared with that being measured or if not, it shall be taken into account by calculation. In addition, it shall allow the continuous me
42、asurement of the force permitting reading to 1 %. 5.5 Recording device, for the simultaneous recording of the force F and the displacement X which provides a curve of F as a function of X (see 7.2). 6 Test specimens 6.1 Dimensions of test specimens Test specimens shall be at the original product thi
43、ckness. Any skins, facings, and/or coatings shall be retained. The test specimens shall be squarely cut and square with sides having dimensions of 300 mm 300 mm. Other dimensions may be specified in the relevant product standard or any other European Technical Specification or may be agreed between
44、parties. The linear dimensions shall be determined in accordance with EN 12085, to the nearest millimetre. The tolerance on parallelism and flatness between the two major faces of the test specimens shall not be greater than 0,5 % of the test specimen side with a maximum of 0,5 mm. BS EN 12430:2013E
45、N 12430:2013 (E) 8 6.2 Number of test specimens The number of test specimens shall be as specified in the relevant product standard. If the number is not specified, then at least three test specimens shall be used. In the absence of a product standard or any other European Technical Specification th
46、e number of test specimens may be agreed between parties. 6.3 Preparation of test specimens Test specimens shall be cut so that the specimen base is normal to the direction of compression of the product in its application. The test specimens shall be cut and prepared by methods that do not change th
47、e original structure of the product. Moulded skins that do not remain with the product in use shall be removed. Rectangular test specimens with parallel major faces shall be cut from the product so that the test specimen base is normal to the direction of the force which is experienced in its applic
48、ation. 6.4 Conditioning of test specimens The test specimens shall be stored for at least 6 h at (23 5) C. In case of dispute they shall be stored at (23 2) C and (50 5) % relative humidity for the time specified in the relevant product standard. 7 Procedure 7.1 Test conditions The test shall be car
49、ried out at (23 5) C. In case of dispute it shall be carried out at (23 2) C and (50 5) % relative humidity. 7.2 Test procedure Measure the linear dimensions to the nearest millimetre in accordance with EN 12085. Place the test specimen in the compression testing machine on the fixed plate so that the indentor is centrally located above the test specimen (see Figure 1). Preload with a force of (2,5 0,25) N corresponding to a pressure of