1、BS EN 12566-7:2016Small wastewater treatmentsystems for up to 50 PTPart 7: Prefabricated tertiary treatment unitsBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 12566-7:2016 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 1
2、2566-7:2016. It supersedes BS EN 12566-7:2013 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee B/505, Wastewater engineering.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purp
3、ort to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2016.Published by BSI Standards Limited 2016ISBN 978 0 580 91477 5 ICS 13.060.30 Compliance with a British Standard cannot confer immunity from legal obliga
4、tions.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2016.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 12566-7:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 12566-7 August 2016 ICS 1
5、3.060.30 Supersedes EN 12566-7:2013English Version Small wastewater treatment systems for up to 50 PT - Part 7: Prefabricated tertiary treatment units Petites installations de traitement des eaux uses jusqu 50 PTE - Partie 7: Units prfabriques de traitement tertiaire Kleinklranlagen fr bis zu 50 EW
6、- Teil 7: Im Werk vorgefertigte Einheiten fr eine dritte ReinigungsstufeThis European Standard was approved by CEN on 25 June 2016. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national stan
7、dard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in a
8、ny other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Rep
9、ublic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEA
10、N COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 12566-7:2016 EBS EN
11、 12566-7:2016EN 12566-7:2016 (E) 2 Contents Page European foreword . 4 1 Scope 6 2 Normative references 6 3 Terms, definitions, symbols and abbreviated terms 6 3.1 Terms and definitions . 6 3.2 Symbols and abbreviated terms 8 4 Product characteristics . 8 4.1 Design 8 4.1.1 General 8 4.1.2 Overall d
12、imensions . 8 4.1.3 Inlets, outlets, internal pipework and connections 8 4.1.4 Access 9 4.2 Load bearing capacity 9 4.3 Tertiary treatment efficiency . 9 4.4 Watertightness 10 4.5 Power consumption 10 4.6 Durability 10 4.6.1 General . 10 4.6.2 Concrete, steel, PVC-U, PE, GRP, PDCPD and flexible shee
13、ts . 10 4.7 Reaction to fire 10 4.7.1 General . 10 4.7.2 Units classified as Class A1 without the need for testing . 11 4.7.3 Units classified according to the test results 11 4.8 Dangerous substances 11 5 Testing, assessment and sampling . 12 5.1 Load bearing capacity . 12 5.1.1 Generals . 12 5.1.2
14、 Load bearing capacity determined by calculation . 12 5.1.3 Load bearing capacity determined by testing . 13 5.2 Tertiary treatment efficiency 15 5.3 Watertightness 15 5.4 Power consumption 15 6 Assessment and verification of constancy of performance AVCP 15 6.1 General . 15 6.2 Type testing 16 6.2.
15、1 General . 16 6.2.2 Test samples, testing and compliance criteria 16 6.2.3 Test reports 18 6.2.4 Shared other party results 18 6.2.5 Cascading determination of the product type results 19 6.3 Factory production control 20 6.3.1 General . 20 6.3.2 Requirements 20 6.3.3 Product specific requirements
16、23 6.3.4 Initial inspection of factory and of FPC 23 6.3.5 Continuous surveillance of FPC . 24 6.3.6 Procedure for modifications 24 BS EN 12566-7:2016EN 12566-7:2016 (E) 3 6.3.7 One-off products, pre-production products (e.g. prototypes) and products produced in very low quantity . 24 7 Nominal desi
17、gnation 25 8 Marking, labelling and packaging . 25 8.1 Marking 25 8.2 Technical information accompanying the unit 26 8.3 Installation instructions . 27 8.4 Operation manual . 27 Annex A (normative) Tertiary treatment efficiency test procedure . 29 A.1 Preliminary requirements 29 A.1.1 General . 29 A
18、.1.2 Installation and commissioning 29 A.1.3 Operation procedures during testing 29 A.1.4 Data to be monitored. 29 A.2 Test procedure 30 A.2.1 Time for establishment 30 A.2.2 Influent characteristics 30 A.2.3 Daily flow pattern for testing . 30 A.2.4 Test procedure 30 A.2.4.1 General . 30 A.2.4.2 Ov
19、erload . 31 A.2.4.3 Power breakdown/Machine breakdown . 31 A.2.4.4 Power consumption . 31 A.2.5 Influent and effluent sampling. 32 A.3 Sample analysis . 32 A.4 Test report 32 Annex B (normative) Definition of processes 33 Annex C (informative) Analysis method 34 Annex ZA (informative) Clauses of thi
20、s European Standard addressing the provisions of the EU Construction Products Regulation . 35 ZA.1 Scope and relevant characteristics 35 ZA.2 Procedure of attestation of conformity of prefabricated tertiary treatment unit 36 ZA.2.1 System(s) of AVCP . 36 ZA.2.2 Declaration of performance (DoP) . 39
21、ZA.2.2.1 General . 39 ZA.2.2.2 Content . 40 ZA.2.2.3 Example of DoP . 41 ZA.3 CE marking and labelling . 43 Bibliography . 46 BS EN 12566-7:2016EN 12566-7:2016 (E) 4 European foreword This document (EN 12566-7:2016) has been prepared by Technical Committee CEN/TC 165 “Wastewater engineering”, the se
22、cretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2017, and conflicting national standards shall be withdrawn at the latest by May 2018. Attention is draw
23、n to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 12566-7:2013. This document has been prepared under a mandate given to CEN
24、by the European Commission and the European Free Trade Association, and supports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. The differences between this version and EN 12566-7:2013 are mainly
25、 editorial changes according to the Construction Product Regulation (CPR) and declaration of power consumption and desludging during treatment efficiency test. The standard series EN 12566 “Small wastewater treatment systems for up to 50 PT” contains the following parts (see Figure 1): Part 1: Prefa
26、bricated septic tanks; Part 3: Packaged and/or site assembled domestic wastewater treatment plants; Part 4: Septic tanks assembled in situ from prefabricated kits; Part 6: Prefabricated treatment unit used for septic tank effluent; Part 7: Prefabricated tertiary treatment unit (this document). For f
27、iltration systems, CEN/TC 165 decided to publish the following CEN Technical reports, which are considered as Code of practices and do not specify treatment requirements: Part 2: Soil infiltration systems; Part 5: Pre-treated Effluent Filtration systems. BS EN 12566-7:2016EN 12566-7:2016 (E) 5 Key A
28、 domestic wastewater 1 prefabricated septic tank B septic tank effluent 2 soil infiltration system C treated infiltrated effluent 3 packaged and/or site assembled domestic wastewater treatment plant D treated wastewater 4 septic tank assembled in situ from prefabricated kit E tertiary treated wastew
29、ater 5 pre-treated effluent filtration system 6 prefabricated treatment unit used for septic tank effluent 7 prefabricated tertiary treatment unit National regulations may specify different arrangements between the products described in the standard series EN 12566. Figure 1 Scheme related to the ar
30、rangement of the parts of EN 12566 According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav
31、 Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 12566-7:2016EN 12566-7:2016 (E) 6 1 Scope This
32、 European Standard specifies requirements, test methods, the marking and evaluation of conformity for a packaged and/or site assembled tertiary treatment unit (see Figure 1). It applies for tertiary treatment units that are placed on the market as complete units used for the tertiary treatment of do
33、mestic wastewater by biological, physical, chemical, electrical processes and coming from: a) units in accordance with EN 12566-3 or EN 12566-6; b) installations designed and constructed in accordance with CEN/TR 12566-5. Equivalent secondary treated effluent may come from existing systems. Package
34、and/or site assembled tertiary treatment units according to this standard consist of one or more watertight tanks without any direct infiltration into the ground, made of concrete, corrosion resistant or coated steel, un-plasticised poly-vinyl chloride (PVC-U), polyethylene (PE), glass reinforced th
35、ermosetting plastics (GRP) based on polyester resin (UP) (GRP-UP), polypropylene (PP), polydicyclopentadiene (PDCPD) and flexible sheets (HDPE, PP, PVE and EPDM). This standard applies to tertiary treatment units for use above ground (outside the building) or buried in the ground where no vehicle lo
36、ads are applied to the unit. This standard does not apply to tertiary treatment systems forming part of units covered by EN 12566-3 and EN 12566-6. This standard does not cover the systems for microorganism reduction. 2 Normative references The following documents, in whole or in part, are normative
37、ly referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 12566-3:2016, Small wastewater treatment systems for up to 50 P
38、T Part 3: Packaged and/or site assembled domestic wastewater treatment plants CEN/TR 12566-5, Small wastewater treatment systems up to 50 PT Part 5: Pre-treated Effluent Filtration systems EN 12566-6:2016, Small wastewater treatment systems for up to 50 PT Part 6: Prefabricated treatment units for s
39、eptic tank effluent EN 13501-1, Fire classification of construction products and building elements Part 1: Classification using data from reaction to fire tests EN 16323:2014, Glossary of wastewater engineering terms 3 Terms, definitions, symbols and abbreviated terms 3.1 Terms and definitions For t
40、he purposes of this document, the terms and definitions given in EN 12566-3:2016, EN 12566-6:2016, EN 16323:2014 and the following apply. BS EN 12566-7:2016EN 12566-7:2016 (E) 7 3.1.1 tertiary treatment additional treatment process which results in further purification than that obtained by applying
41、 primary and secondary treatment Note 1 to entry: It is recommended that the expression for the treatment, e.g. nitrogen removal, phosphorus removal, polishing effects, suspended solid removal, is used since in some case the tertiary treatment can also be integrated in the secondary treatment. 3.1.2
42、 packaged unit prefabricated factory-built unit 3.1.3 site assembled unit unit composed of prefabricated components assembled on site coming from one manufacturer 3.1.4 biological processes processes in which the treatment is mainly carried out by micro-organism activity 3.1.5 physical processes pro
43、cesses in which the treatment is mainly carried out by using the physical properties of a media 3.1.6 chemical processes processes in which the treatment is mainly carried out by the addition of chemical agents 3.1.7 electrical processes processes in which the treatment is mainly carried out by the
44、use of electricity 3.1.8 product family group of products in which, for the purpose of evaluation, the selected property(s) is/are similar for all products within the group Note 1 to entry: The definition of family takes into account at least similar shape, equipment, materials and conditions of end
45、 use and ensures the minimum hydraulic efficiency and minimum structural behaviour for all the products in the range. Note 2 to entry: The minimum level of performance (hydraulic efficiency and structural behaviour) are given by the test carried out on one model of the family. 3.1.9 tertiary treatme
46、nt retrofit unit tertiary treatment unit installed within an existing package and/or site assembled domestic wastewater treatment plant in accordance with EN 12566-3, or a secondary treatment unit in accordance with EN 12566-6 or a pre-treated effluent filtration system in accordance with CEN/TR 125
47、66-5 Note 1 to entry: Where such a retrofit unit affects the declared performance of EN 125663 or EN 125666 unit in which it is installed, then the overall unit should be tested for its conformity with the relevant standard. BS EN 12566-7:2016EN 12566-7:2016 (E) 8 3.1.10 nominal designation expresse
48、d as an integer giving the maximum number of population equivalent appropriate to the plant 3.2 Symbols and abbreviated terms The following symbols and abbreviations are used in this standard: BOD5(or BOD7) Biochemical oxygen demand at 5 days (or 7 days) COD Chemical oxygen demand SS Suspended solid
49、s Total N Total nitrogen Total P Total phosphorus TOC Total organic carbon PP Polypropylene PDCPD Polydicyclopentadiene HDPE High Density Polyethylene PVC Polyvinyl Chloride EPDM Ethylene Propylene Diene Monomer PE Polyethylene 4 Product characteristics 4.1 Design 4.1.1 General Tertiary treatment units shall be designed to be structurally stable with the expected loads for the intended use. In addition, the units shall be durable, watertight and corrosion resistant. Where electrical, mechanical or hydraulic malfunction of the unit could lead to