1、BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Light and lighting - Measurement and presentation of photometric data of lamps and luminairesPart 2: Presentation of data for indoor and outdoor work placesBS EN 130322:2017EUROPEANSTANDARDNORME EUROPENNE EUROPISCHE NOR
2、MEN 13032-2 November 2017ICS 17.180.20; 29.140.01 Supersedes EN 13032-2:2004EnglishVersionLight and lighting - Measurement and presentation ofphotometric data of lamps and luminaires - Part 2: Presentation of data for indoor and outdoor work places Lumire et clairage - Mesure et prsentation desdonne
3、s photometriques des lampes et luminaires -Partie 2: Prsentation desdonnes utiliss dans leslieux de travail intrieurs etextrieursLicht und Beleuchtung - Messung und Darstellungphotometrischer Daten von Lampen und Leuchten - Teil 2: Darstellung der Daten fr Arbeitssttten in Innenrumen und im FreienTh
4、is European Standard was approved by CEN on 18 September 2017. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving thisEuropean Standard the status of a national standard without any alteration.Up-to-date lists and bibliographical refer
5、encesconcerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made bytranslation under the responsibility of a CEN m
6、ember into its own language and notified to the CEN-CENELEC ManagementCentre has the same status as the officialversions.CEN members are the nationalstandards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, Fran
7、ce, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCH
8、ES KOMITEE FR NORMUNGCEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by any means reservedworldwide for CENnational Members.Ref. No. EN 13032-2:2017 ENational forewordThis British Standard is the UK implementation of EN 130322:2017
9、. It supersedes BS EN 130322:2004 which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee EL/1, Light and lighting applications.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport
10、to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2018 Published by BSI Standards Limited 2018ISBN 978 0 580 95119 0ICS 29.140.01; 17.180.20Compliance with a British Standard cannot confer immunity from legal o
11、bligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2018.Amendments/corrigenda issued since publicationDate Text affectedBRITISH STANDARDBS EN 130322:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13032-2 November
12、2017 ICS 17.180.20; 29.140.01 Supersedes EN 13032-2:2004English Version Light and lighting - Measurement and presentation of photometric data of lamps and luminaires - Part 2: Presentation of data for indoor and outdoor work places Lumire et clairage - Mesure et prsentation des donnes photometriques
13、 des lampes et luminaires - Partie 2: Prsentation des donnes utiliss dans les lieux de travail intrieurs et extrieurs Licht und Beleuchtung - Messung und Darstellung photometrischer Daten von Lampen und Leuchten - Teil 2: Darstellung der Daten fr Arbeitssttten in Innenrumen und im Freien This Europe
14、an Standard was approved by CEN on 18 September 2017. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references c
15、oncerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member
16、 into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, Franc
17、e, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPIS
18、CHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13032-2:2017 EBS EN 130322:2017EN 13032-2:2017 (E) 2 Contents Page European foreword . 4
19、Introduction 5 1 Scope 6 2 Normative references 6 3 Terms and definitions . 6 4 Luminaire data . 7 4.1 General 7 4.2 Essential luminaire data . 7 4.2.1 General 7 4.2.2 Luminaire code 7 4.2.3 Dimensions of the luminous parts of the luminaire . 7 4.2.4 Luminaire luminous flux 7 4.2.5 Luminous intensit
20、y table 8 4.2.6 Luminance table 9 4.2.7 Unified Glare Rating . 9 4.2.8 Ballast lumen factor . 9 4.2.9 Shielding angle . 9 4.2.10 Rated luminaire power (Pi) . 9 4.2.11 Luminaire lumen maintenance factor . 9 4.2.12 Luminaire survival factor . 9 4.2.13 General colour rendering index (Ra) . 10 4.2.14 Co
21、rrelated colour temperature (TCP) 10 4.3 Useful luminaire data . 10 4.3.1 General . 10 4.3.2 Physical dimensions of the luminaire 10 4.3.3 Intensity diagram . 10 4.3.4 Maximum and nominal spacing to height ratio . 10 4.3.5 Light output ratios . 10 4.3.6 Upward flux fraction (of a luminaire) . 10 4.3
22、.7 Downward flux fraction (of a luminaire) 10 4.3.8 Luminaire luminous efficacy 10 4.3.9 Luminaire maintenance factor (FLM) . 10 4.3.10 Utilization factor tables . 11 4.3.11 Service Conversion factors . 11 4.3.12 Individual special colour rendering indices (Ri) 11 5 Lamp data 11 5.1 General . 11 5.2
23、 Essential lamp data 11 5.2.1 General . 11 5.2.2 Lamp code . 11 5.2.3 Lamp dimensions . 11 5.2.4 Rated Luminous flux . 11 5.2.5 Lamp lumen maintenance factor (FLLM) . 11 BS EN 130322:2017EN 13032-2:2017 (E) 3 5.2.6 Lamp survival factor (FLS) 11 5.2.7 General colour rendering index (Ra) . 12 5.2.8 Co
24、rrelated colour temperature (TCP) . 12 5.3 Useful lamp data 12 5.3.1 General . 12 5.3.2 Lamp energy efficiency class 12 5.3.3 Nominal lamp wattage (Plamp) 12 5.3.4 Individual special colour rendering indices (Ri) . 12 Annex A (normative) Calculation of UF tables . 13 A.1 General . 13 A.2 The step-by
25、-step calculation procedure. 13 A.3 CEN Flux Code . 15 Bibliography . 22 BS EN 130322:2017EN 13032-2:2017 (E) 4 European foreword This document (EN 13032-2:2017) has been prepared by Technical Committee CEN/TC 169 “Light and lighting”, the secretariat of which is held by DIN. This European Standard
26、shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by May 2018, and conflicting national standards shall be withdrawn at the latest by May 2018. Attention is drawn to the possibility that some of the elements of this document
27、 may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 13032-2:2004. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement t
28、his European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbi
29、a, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 130322:2017EN 13032-2:2017 (E) 5 Introduction There are many lighting solutions that can satisfy the lighting criteria specified in EN 12464-1 and EN 12464-2. To design these solutions, photometric data of the eq
30、uipment are required. The equipment may include the commonly used general purpose luminaires as well as uplighters, wall washers, adjustable directional lights, floodlights, desk lights, etc. This document specifies the required data. BS EN 130322:2017EN 13032-2:2017 (E) 6 1 Scope This European Stan
31、dard specifies the required data for lamps and luminaires for the verification of conformity to the requirements of EN 12464-1 and EN 12464-2. It also specifies data that are commonly used for lighting of indoor and outdoor work places. When these data are provided, they should conform to this docum
32、ent. An increasing number of luminaires mainly those with LED are luminaires with non-replaceable light sources. Therefore data should always be given for luminaires. For luminaires with replaceable lamps, lamp data should also be provided. NOTE Product, safety and performance data can be found in C
33、ENELEC documents (see Bibliography). 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the ref
34、erenced document (including any amendments) applies. EN 12464-1, Light and lighting Lighting of work places Part 1: Indoor work places EN 12464-2:2014, Light and lighting Lighting of work places Part 2: Outdoor work places EN 12665, Light and lighting Basic terms and criteria for specifying lighting
35、 requirements EN 13201-3, Road lighting Part 3: Calculation of performance CIE 117, Discomfort glare in interior lighting 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 12665 and the following apply. 3.1 lamp energy efficiency class energy efficiency
36、 class assigned to the lamp in accordance with the energy efficiency index defined in Reg. 874/2012 3.2 luminaire lumen maintenance factor FLuLMratio of luminous flux of a luminaire at a given time in the life to the initial luminous flux Note 1 to entry: The luminaire lumen maintenance factor is ap
37、plied like the lamp lumen maintenance factor but only to luminaires having non replaceable lamps. BS EN 130322:2017EN 13032-2:2017 (E) 7 3.3 luminaire survival factor FLuSfraction of the total number of luminaires which continue to operate at a given time under defined conditions Note 1 to entry: Th
38、e luminaire survival factor includes the built-in control gear and is therefore not equivalent to the lamp survival factor. 3.4 upward flux fraction ratio of the upward flux to the total flux of a luminaire 3.5 downward flux fraction ratio of the downward flux to the total flux of a luminaire 4 Lumi
39、naire data 4.1 General Data shall be provided for luminaires with replaceable and non-replaceable lamps. 4.2 Essential luminaire data 4.2.1 General The following luminaire data shall be provided for verification, where applicable. 4.2.2 Luminaire code 4.2.3 Dimensions of the luminous parts of the lu
40、minaire The dimensions of those parts of the luminaire, from which light is emitted to produce the luminous intensity values, shall be given in m or m2. NOTE For further information see CIE 117:1995, Annex C. 4.2.4 Luminaire luminous flux For luminaires the rated luminous flux of the luminaire shall
41、 be given. NOTE 1 For guidance on providing LED luminaire rated flux see EN 130324:2015, Clause 4 and Annex E. NOTE 2 For luminaires with replaceable lamps, the rated luminous flux of the luminaire can be derived by multiplying the rated luminous flux of the lamp by the light output ratio (LOR) of t
42、he luminaire. If the ballast(s) of the luminaire mention(s) a ballast lumen factor (BLF) value, it is advised in this case to multiply first LOR by the BLF value. For guidance see also EN 130321. BS EN 130322:2017EN 13032-2:2017 (E) 8 4.2.5 Luminous intensity table The intensity table shall be given
43、 either as absolute or as normalized luminous intensity table. a) Absolute luminous intensity table: Absolute luminous intensity data (in candela (cd) of a lamp or a luminaire (equipped with a lamp or lamps of specified type and power) shall be given as a table. Lamp type and rated power shall be de
44、clared. b) Normalized luminous intensity table: Normalized luminous intensity data of a luminaire (equipped with a lamp or lamps of specified type and power) shall be given as a table, normalized to a luminous flux of 1 000 lm and provided in candela per kilolumen (cd klm1). The source of the normal
45、ization shall be stated (lamp or luminaire). The minimum number of C-planes and -angles at which the I-values shall be presented, is given in Tables 1 and 2. Table 1 Number of C-planes for various intensity distributions Luminous intensity distribution C-planes Radially symmetric One C-plane Symmetr
46、ic about two planes Every 15 from 0 to 90 Symmetric about one plane Every 15 from 0 to 180 or every 15 from 90 to 270 Asymmetric Every 15 from 0 to 360 Table 2 Number of -angles for various types of luminaires Type of luminaire Downward Flux Fraction FDF-angles Downlighting 0,9 Every 5 from 0 to 90
47、Downlighting with upward component 0,1 to 0,9 Every 5 from 0 to 180 Uplighting 0,1 Every 5 from 90 to 180 For floodlights, both used in indoor and outdoor lighting installations, the measurement and presentation of the normalized I-table might be in B- instead of C- notation. For TI-calculations (se
48、e EN 12464-2:2014, Table 3) the data as required in EN 13201-3 shall be provided. NOTE 1 The Downward Flux Fraction FDF is the ratio of the Downward Light Output Ratio RDLO and the Light Output Ratio RLO of the luminaire: FDF = RDLO/RLO (see also 4.3.5). NOTE 2 Luminaires with a concentrated intensi
49、ty distribution might require more angles at which the luminous intensity data are present (e.g. every 1 in the area where 90 % of the luminous flux is emitted). NOTE 3 Data at finer intervals might be required for more accurate calculations and for lighting software involving visualizations. BS EN 130322:2017EN 13032-2:2017 (E) 9 4.2.6 Luminance table The table shall give the average luminaire luminance (at maximum lumen output) at elevation angles of 65, 70, 75, 80 and 85 from the do