1、BS EN13126-6:2008ICS 91.190NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDBuilding hardware Requirements andtest methods forwindows and doorsheight windowsPart 6: Variable geometry stay hinges(with or without a friction stay)This British Standardwas published u
2、nder theauthority of the StandardsPolicy and StrategyCommittee on 31 March2009 BSI 2009ISBN 978 0 580 58563 0Amendments/corrigenda issued since publicationDate CommentsBS EN 13126-6:2008National forewordThis British Standard is the UK implementation of . It supersedes DDCEN/TS 13126-6:2004 which is
3、withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee B/538/4, Building hardware.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Us
4、ers are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.EN 13126-6:2008BS EN 13126-6:2008EUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 13126-6November 2008ICS 91.190 Supersedes CEN/TS 13126-6:2004 English VersionBuilding har
5、dware - Requirements and test methods for windowsand doors height windows - Part 6: Variable geometry stayhinges (with or without a friction stay)Quincaillerie pour le btiment - Exigences et mthodesdessai des ferrures de fentres et portes-fentres - Partie6: Compas friction gomtrie variable (avec ou
6、sanssystme de friction)Baubeschlage - Beschlge fr Fenster und Fenstertren -Anforderungen und Prfverfahren - Teil 6: Scheren mitvernderlicher Geometrie (mit oder ohne Friktionssystem);Deutsche Fassung EN 13126-6:2008This European Standard was approved by CEN on 5 October 2008.CEN members are bound to
7、 comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Mana
8、gement Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as th
9、eofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia,
10、Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2008 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN
11、national Members.Ref. No. EN 13126-6: EBS EN 13126-6:2008EN 13126-6:2008 (E) 2 Contents Page Foreword. 4 1 Scope 6 2 Normative references . 6 3 Terms and definitions. 6 4 Classification. 7 4.1 General. 7 4.2 Category of use (1 first digit) 7 4.3 Durability (2 second digit). 7 4.4 Mass (3 third digit
12、) . 7 4.5 Fire resistance (4 fourth digit) 7 4.6 Safety in use (5 fifth digit) . 7 4.7 Corrosion resistance (6 sixth digit) 8 4.8 Security (7 seventh digit) 8 4.9 Application (8 eighth digit) 8 4.10 Test sizes size limitations (9 ninth digit) 8 4.11 Example of classification for variable geometry st
13、ay hinges (with or without a friction system EN 13126-6) 9 5 Requirements 10 5.1 General. 10 5.2 Integrated restrictors 10 5.3 Additional requirements. 10 5.3.1 Pull-in and pull-in abuse test . 10 5.3.2 Friction test (where applicable) . 10 5.3.3 Obstructed track test 11 5.3.4 Ease of sash movement
14、test 11 5.3.5 Durability test 11 5.3.6 Durability pull-in test 12 5.3.7 Simulated negative pressure test 12 5.3.8 Static load test. 13 5.3.9 Additional load test. 13 6 Test apparatus. 13 6.1 General. 13 6.2 Assembly . 13 6.2.1 General. 13 6.2.2 Fixing 13 6.3 Additional equipment . 14 6.3.1 Block for
15、 pull-in abuse test 14 6.3.2 Steel cross for simulated negative pressure test 14 7 Test methods. 14 7.1 Samples . 14 7.2 Pull-in test 14 7.2.1 General. 14 7.2.2 Pull-in test procedure . 14 7.3 Friction test 15 7.3.1 General. 15 7.3.2 Friction test procedure. 15 7.4 Obstructed track test procedure .
16、15 7.5 Pull-in abuse test 16 BS EN 13126-6:2008EN 13126-6:2008 (E) 3 7.6 Ease of sash movement test procedure. 16 7.7 Durability test 16 7.7.1 General. 16 7.7.2 Durability pull-in test procedure 17 7.8 Simulated negative pressure test 17 7.9 Static load test procedure 18 7.10 Additional load test pr
17、ocedure 18 7.11 Corrosion resistance 18 Annex A (normative) Types of variable geometry stay hinges (with or without a friction system). 19 Annex B (informative) Test method diagrams. 20 Annex C (normative) Flow chart of test procedures. 25 BS EN 13126-6:2008EN 13126-6:2008 (E) 4 Foreword This docume
18、nt (EN 13126-6:2008) has been prepared by Technical Committee CEN/TC 33 “Doors, windows, shutters, building hardware and curtain walling”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or
19、 by endorsement, at the latest by May 2009, and conflicting national standards shall be withdrawn at the latest by May 2009. This document supersedes CEN/TS 13126-6:2004. This European Standard is one of a series of European Standards dedicated to building hardware products. A full contribution to t
20、he preparation of this European Standard has been made by the European manufacturers organization “ARGE” and national standards bodies. EN 13126 Building hardware Requirements and test methods for windows and doors height windows consists of the following parts: Part 1: Requirements common to all ty
21、pes of hardware Part 2: Casement fastener handles1)Part 3: Manoeuvring fittings for espagnolette bolts/sliding button1)Part 4: Espagnolette bolts1)Part 5: Devices that restrict the opening of windows1)Part 6: Variable geometry stay hinges (with or without a friction system) Part 7: Finger catches Pa
22、rt 8: Tilt the point about which the casement pivots being near the outer end of a link arm. The freedom of movement of the variable geometry stay hinge system is controlled by the friction between some or all of its moveable components NOTE Friction is usually applied either at the pivot points or
23、between a sliding shoe and its track. BS EN 13126-6:2008EN 13126-6:2008 (E) 7 3.2 working stack height perpendicular distance between the outer faces of the frame plate and casement plate of a variable geometry stay hinge (with or without a friction system) 3.3 pull-in characteristic of the design o
24、f the variable geometry stay hinge (with or without a friction system), which maintains the non-locking edge of a casement in contact with the window frame or weather stripping when the casement fastener is closed 3.4 integrated restrictor mechanism that is an integral part of the variable geometry
25、stay hinge (with or without a friction system) that limits the initial opening of the window 3.5 declared minimum opening distance measured between the nearest adjacent edges of the sash and frame as the outward movement, from fully closed to where the friction in a variable geometry stay hinge with
26、 a friction system is sufficient to conform to the requirements of 7.3 4 Classification 4.1 General The classification for variable geometry stay hinge (with or without a friction system) shall be in accordance with the requirements of EN 13126-1:2006, Clause 4. 4.2 Category of use (1 first digit) N
27、o marking is required for the category of use in accordance with EN 13126-1:2006, 4.2. 4.3 Durability (2 second digit) Grades shall be in accordance with EN 13126-1:2006, 4.3. 4.4 Mass (3 third digit) Grades shall be in accordance with EN 13126-1:2006, 4.4. 4.5 Fire resistance (4 fourth digit) One g
28、rade shall be identified in accordance with EN 13126-1:2006, 4.5. grade 0: no requirements. 4.6 Safety in use (5 fifth digit) One grade shall be identified in accordance with EN 13126-1:2006, 4.6. grade 1: hardware shall conform to the requirements of EN 13126-1 and EN 13126-6. BS EN 13126-6:2008EN
29、13126-6:2008 (E) 8 4.7 Corrosion resistance (6 sixth digit) Grades shall be in accordance with EN 13126-1:2006, 4.7. 4.8 Security (7 seventh digit) No marking is required for the category of security in accordance with EN 13126-1:2006, 4.8. 4.9 Application (8 eighth digit) The eighth digit shows “6/
30、1”, “6/2” or “6/3” indicating the part of the standard which was used for testing the variable geometry stay hinges (with or without a friction system) and their common application to the following window assemblies in accordance with EN 13126-1:2006, 4.9. Three grades are identified: grade 6/1: ind
31、icating window operates on a horizontal axis of rotation: type C: bottom-hung window, inward opening or outward opening; type D: top-hung window, inward opening or outward opening; type H: projecting top-hung window, inward or outward opening; type J: projecting bottom-hung window, inward or outward
32、 opening; type U: top-hung, inward opening window multi-light; type V: bottom-hung, inward opening window multi-light; grade 6/2: indicating window operates on a vertical axis of rotation: type A: side-hung window inward opening; type B: side-hung window outward opening; grade 6/3: indicating the wi
33、ndow operates on both horizontal and vertical axis of rotation. 4.10 Test sizes size limitations (9 ninth digit) The ninth digit shows the test sizes in accordance with EN 13126-1:2006, 4.10 as follows: S.W.2)in mm / S.H.3)in mm tolerance of -2 mm/+0 mm EXAMPLE 1 200 S.W. 900 S.H. Where a variable g
34、eometry stay hinge (with or without friction) operates on a horizontal axis of rotation, the test size is determined in accordance with Table 1. Where a variable geometry stay hinge (with or without friction) operates on a vertical axis of rotation, the test size is determined in accordance with Tab
35、le 2. 2)S.W. = sash width 3)S.H. = sash height BS EN 13126-6:2008EN 13126-6:2008 (E) 9 Table 1 Test window size for top hung variable geometry stay hinges Overall length of variable geometry stay hinge (mm) Sash width (mm) Sash height (mm) 30 kg 1 500 N 500+N On completion of the simulated negative
36、pressure test in accordance with 7.8: recorded additional displacement of the datum surfaces shall be a maximum of 1,5 mm. BS EN 13126-6:2008EN 13126-6:2008 (E) 13 5.3.8 Static load test The test specified in 7.9 shall be used only on side hung windows (type A and type B) to ensure the mechanical st
37、rength of the hardware is appropriate for the intended use. On completion of the static load test in accordance with 7.9: side hung projecting reversible hardware shall continue to function normally; measured clearance gap between sash and frame shall not have increased by more than 3 mm from the me
38、asured clearance gap prior to the test commencing. 5.3.9 Additional load test The test specified in 7.10 shall be used only on side-hung windows (type A and type B) to comply with safety in use, the test specified in 7.10 shall be used. On completion of the additional load test in accordance with 7.
39、10: side-hung projecting reversible hardware shall continue to hold the sash. NOTE Permanent deformation of the hardware is acceptable. 6 Test apparatus 6.1 General The variable geometry stay hinge (with or without a friction system) shall be installed in the test specimen for testing as in EN 13126
40、-1:2006, Clause 6 and in accordance with the manufacturers fixing instructions. The hardware manufacturer shall provide test specimens for the testing institute. A drawing of the profile cross-section with relevant information shall be enclosed in the test application, which also contains the necess
41、ary hardware installation information for the windows. NOTE Purpose-built test steel test apparatus may also be used. Mounting blocks should be used to ensure the fixing gap on the test apparatus is equal to the working stack height of the variable geometry stay hinge (with or without a friction sys
42、tem). 6.2 Assembly 6.2.1 General The test shall be conducted on a test rig which corresponds in function and shape to the window for which the hardware was intended. The hardware tested shall be in accordance with the manufacturers recommendation for size and mass of the test specimen. The test rig
43、shall be provided with adjustable datum surfaces near the free corners of the edge of the casements, opposite to its detected locking rail, so that wear and loss of pull-in can be detected. 6.2.2 Fixing Any gap between sash and outer frame shall be equal to the working stack height of the variable g
44、eometry stay hinge (with or without a friction system) 10+mm. BS EN 13126-6:2008EN 13126-6:2008 (E) 14 If the fixing position of the variable geometry stay hinge (with or without a friction system) is not specified, the variable geometry stay hinge (with or without a friction system) shall be mounte
45、d with its centre line in the plane containing the centre of gravity of the sash, or test panel, to 3 mm and as close to its free corners as practicable. 6.3 Additional equipment 6.3.1 Block for pull-in abuse test The pull-in abuse test requires a softwood block of dimensions (25 mm 25 mm 6 mm) 10 %
46、 (see Figure B.3). 6.3.2 Steel cross for simulated negative pressure test The simulated negative pressure test requires a welded steel cross to be used to distribute the applied force to the mid-points of the panel rails and stiles. 7 Test methods 7.1 Samples Four samples shall be used for testing i
47、n accordance with this European Standard: sample A pull-in, friction and pull-in abuse tests; sample B pull-in, durability and simulated negative pressure tests; sample C corrosion tests; sample D retained for reference control. NOTE 1 Sample C should only be necessary if no test report can be suppl
48、ied from the manufacturer regarding the testing of the hardware component or set in accordance with EN 1670. NOTE 2 Sample D should be retained by the test institute for the duration of the validity of the test report. 7.2 Pull-in test 7.2.1 General Position the datum surfaces into the corners where
49、 the variable geometry stay hinges (with or without a friction system) are fitted, opposite the locking rail (see Figure B.5). Adjust the datum surfaces so that a measurable gap of between 2 mm to 3 mm is achieved when a force of 10 N 1 N is applied horizontally in the opening direction to each corner in turn. Measure and record each of the gaps to establish the initial datum position for the test. The datum surfaces shall not be readjusted until all tests on t