1、BRITISH STANDARD BS EN 13141-3:2004 Ventilation for buildings Performance testing of components/products for residential ventilation Part 3: Range hoods for residential use The European Standard EN 13141-3:2004 has the status of a British Standard ICS 91.140.30; 97.040.20 BS EN 13141-3:2004 This Bri
2、tish Standard was published under the authority of the Standards Policy and Strategy Committee on 29 January 2004 BSI 29 January 2004 ISBN 0 580 43329 3 National foreword This British Standard is the official English language version of EN 13141-3:2004. The UK participation in its preparation was en
3、trusted to Technical Committee RHE/2, Air distribution and air diffusion, which has the responsibility to: A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications
4、referred to in this document may be found in the BSI Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online. This publication does not purport to include all the necessary p
5、rovisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretat
6、ion, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. Summary of pages This document comprises a front cover, an inside front cover, the EN title page, pages 2 to 9 and a back cover. The BSI copyright
7、notice displayed in this document indicates when the document was last issued. Amendments issued since publication Amd. No. Date CommentsEUROPEANSTANDARD NORMEEUROPENNE EUROPISCHENORM EN131413 January2004 ICS91.140.30;97.040.20 Englishversion VentilationforbuildingsPerformancetestingof components/pr
8、oductsforresidentialventilationPart3:Range hoodsforresidentialuse VentilationdesBtimentsEssaisdesperformancesdes composants/produitspourlaventilationdeslogements Partie3:Hottesdecuisinepourutilisationdomestique LftungvonGebudenLeistungsprfungenvon Bauteilen/ProduktenfrdieLftungvonWohnungenTeil 3:Dun
9、stabzugshaubenfrdenHausgebrauch ThisEuropeanStandardwasapprovedbyCENon22October2003. CENmembersareboundtocomplywiththeCEN/CENELECInternalRegulationswhichstipulatetheconditionsforgivingthisEurope an Standardthestatusofanationalstandardwithoutanyalteration.Uptodatelistsandbibliographicalreferencesconc
10、ernings uchnational standardsmaybeobtainedonapplicationtotheCentralSecretariatortoanyCENmember. ThisEuropeanStandardexistsinthreeofficialversions(English,French,German).Aversioninanyotherlanguagemadebytra nslation undertheresponsibilityofaCENmemberintoitsownlanguageandnotifiedtotheCentralSecretariat
11、hasthesamestatusast heofficial versions. CENmembersarethenationalstandardsbodiesofAustria,Belgium,Cyprus,CzechRepublic,Denmark,Estonia,Finland,France, Germany,Greece,Hungary,Iceland,Ireland,Italy,Latvia,Lithuania,Luxembourg,Malta,Netherlands,Norway,Poland,Portugal, Slovakia, Slovenia,Spain,Sweden,Sw
12、itzerlandandUnitedKingdom. EUROPEANCOMMITTEEFORSTANDARDIZATION COMITEUROPENDENORMALISATION EUROPISCHESKOMITEEFRNORMUNG ManagementCentre:ruedeStassart,36B1050Brussels 2004CEN Allrightsofexploitationinanyformandbyanymeansreserved worldwideforCENnationalMembers. Ref.No.EN131413:2004:EEN131413:2004(E) 2
13、 Contents page Foreword .3 1 Scope 5 2 Normativereferences 5 3 Termsanddefinitions . 5 4 Performancetestingofaerodynamiccharacteristics6 4.1 Principle6 4.2 TestInstallationandConditions 6 4.3 Testprocedure .6 4.4 Analysisofresults. 6 4.5 Presentationofresults. .7 5 Performancetestingofacousticcharac
14、teristics .7 5.1 Noiseproduction .7 5.2 Insertionloss .7 6 Performancetestingofgreaseabsorption .8 7 Performancetestingofodourextraction. .8 8 Performancetestingofelectricalpower . 8 8.1 Method8 8.2 Analysisofresults. 8 8.3 Presentationofresults. .8 9 Safety 8 Bibliography9EN131413:2004(E) 3 Forewor
15、d Thisdocument(EN131413:2004)hasbeenpreparedbyTechnicalCommitteeCEN/TC156“Ventilationfor buildings“,thesecretariatofwhichisheldbyBSI. ThisEuropeanStandardshallbegiventhestatusofanationalstandard,eitherbypublicationofanidentical textorbyendorsement,atthelatestbyJuly2004,andconflictingnationalstandard
16、sshallbewithdrawnat thelatestbyJuly2004. Thestandardisoneofaseriesofstandardsonresidentialventilation.Theperformancecharacteristicsofthe components/productsforresidentialventilationaregiveninEN13142. ThepositionofthisstandardinthefieldofmechanicalbuildingservicesisshowninFigure1. AccordingtotheCEN/C
17、ENELECInternalRegulations,thenationalstandardsorganizationsofthefollowing countriesareboundtoimplementthisEuropeanStandard:Austria,Belgium,Cyprus,CzechRepublic, Denmark,Estonia,Finland,France,Germany,Greece,Hungary,Iceland,Ireland,Italy,Latvia,Lithuania, Luxembourg,Malta,Netherlands,Norway,Poland,Po
18、rtugal,Slovakia,Slovenia,Spain,Sweden,Switzerland andUnitedKingdom.EN131413:2004(E) 4 MechanicalBuildingServices Controlsystems Ventilationandairconditioning systems Heatingsystems Ductwork Airterminal devices Airhandling units Mechanicaland naturalresidential ventilation Designcriteria fortheindoor
19、 environment System performance Installation Components/productsfor residentialventilation Requiredandoptional performance characteristics Performancetestingof components/productsfor residentialventilation Simplifiedcalculation methodsfor residentialventilation systems Designand dimensioning forresi
20、dential ventilationsystems Performancetesting andinstallation checksforresidential ventilationsystems Part1:Externallyandinternallymountedairtransferdevices Part2:Exhaustandsupplyairterminaldevices Part3:Rangehoodsforresidentialuse Part4:Fansusedinresidentialventilationsystems Part5:Cowlsandroofoutl
21、etterminaldevices Part6:Exhaustventilationsystempackagesusedinasingledwelling Part7:Mechanicalsupplyandexhaustventilationunits(including heatrecovery)formechanicalventilationsystemsintendedforsingle familydwellings Figure1PositionofEN131413inthefieldofmechanicalbuildingservicesEN131413:2003(E) 5 1Sc
22、ope ThisEuropeanStandardspecifiesmethodsformeasuringthemainperformancecharacteristicsofrangehoodsfor residentialuse.Itappliestorecirculatingrangehoods,airextractionrangehoodsincorporatingafanandair extractionrangehoodswithoutfan. Thisstandarddoesnotspecifyvaluesforperformancecharacteristics. 2 Norma
23、tivereferences ThisEuropeanStandardincorporates,bydatedorundatedreference,provisionsfromotherpublications.These normativereferencesarecitedattheappropriateplacesinthetext,andthepublicationsarelistedhereafter.For datedreferences,subsequentamendmenttoorrevisionsofanyofthesepublicationsapplytothisEurop
24、ean Standardonlywhenincorporatedinitbyamendmentorrevision.Forundatedreferencesthelatesteditionofthe publicationreferredtoapplies(includingamendments). EN12792, VentilationforbuildingsSymbols,terminologyandgraphicalsymbols. EN131412:2003, VentilationforbuildingsPerformancetestingofcomponents/products
25、forresidentialventilation Part2:Exhaustandsupplyairterminaldevices. EN131414:2003, VentilationforbuildingsPerformancetestingofcomponents/productsforresidentialventilation Part4:Fansusedinresidentialventilationsystems. EN60335231, SafetyofhouseholdandsimilarelectricalappliancesPart2:Particularrequire
26、mentsforrange hoods(IEC60335231:1995). ISO5801, IndustrialFansPerformancetestingusingstandardizedairways . IEC61591:1997, HouseholdrangehoodsMethodsformeasuringperformance. 3 Termsanddefinitions ForthepurposesofthisEuropeanStandard,thetermsanddefinitionsgiveninEN 12792andEN131412together withthefoll
27、owingdefinitionsapply. 3.1 rangehood(cookerhood) deviceintendedtocollectcontaminatedairfromaboveacookingapplianceandeitherdischargeitintotheroomor removeitfromtheroom NOTE Rangehoodmayincorporateoneormoreofthefollowingcomponents: filters(essentialwhenthecontaminatedairisdischargedintotheroom); fan;
28、firedamper; nonreturnflowdamper. 3.2 recirculatingairrangehood rangehoodcontainingfilterstoremovecontaminantsafterwhichthecleanedairisdischargedbackintotheroom 3.3 airextractionrangehood rangehoodwhichdischargesthecollectedairtotheoutsideofthebuildingbymeansofductingEN131413:2003(E) 6 3.4 testvoltag
29、e voltagetobeusedforsupplyingtherangehoodduringthetesting 3.5 greaseabsorptionfactor measureofthepercentageofgreaseretainedwithinafilter 3.6 odourreductionfactor measureofthecapabilityoftherangehoodtoreduceodours 3.7 odourdispersiontime timetakentoreduceodourtoadefinedlevelafterodourgeneratingsource
30、hasbeenswitchedoff 4 Performancetestingofaerodynamiccharacteristics 4.1Principle Thetestconsistsinmeasuringthevolumeflowratesinducedthroughthedeviceatseveralvaluesofthepressure differenceacrossthedeviceinordertodefinetheflowrate/pressurecharacteristiccurve. Testsshallbecarriedoutwithallnewfilters. R
31、angehoodsnotincorporatingafanshallbetestedaccordingtotheExhaust/SupplyAirTerminalDevicetest method,describedinEN131412:2003,clause4. Wherereferenceismadetoexistingtestmethods,careshallbetakenintheinstallationoftherangehoodbecause itsdimensionscouldbemuchlargerthanthoseofotherairterminaldevices. 4.2
32、TestInstallationandConditions Fortherecirculatingairrangehood,thetestinstallationandconditionsshallconformto4.2ofprEN141344:2003 underCategoryAconditions. Fortheairextractionrangehood(incorporatingafan),thetestinstallationandconditionsshallconformto4.2of EN131414:2003underCategoryBconditions.Theaire
33、xtractionrangehoodshallbeconnectedtoductwork whichgivesapressuredropof30Pathroughtheductworkatmaximumflowrate. 4.3 Testprocedure Thetestprocedureshallconformto4.3ofEN131414:3003. Measurementsshallbemadeatthelowestandhighestairflowratesettings,andforanyotherlevelspecifiedby themanufacturer. Whereasin
34、glevalueisassignedbythemanufacturerasratedvoltage,thisshallbethetestvoltage.Wherea voltagerangeisassignedtotheproductbythemanufacturerthatincludes230 V,thetestvoltageshallbe 230V. Thisvoltageshallbemaintainedto 1%throughoutthetesting. 4.4 Analysisofresults Analysisoftheresultsshallconformto4.4ofEN13
35、1414:2003,forthedeterminationoftheflowrate/pressure characteristiccurves.EN131413:2003(E) 7 Thevolumetricairflowrateoftherangehoodshallthenbedetermined,foreachsettingoffanspeed,bythe intersectionbetweenthecharacteristiccurveandtheairflow/pressurecurvesoftwostandardductsystems. 4.5Presentation of res
36、ults Resultsshallbepresentedaccordingto4.4ofEN131414:2003. 5 Performancetestingofacousticcharacteristics 5.1Noise production 5.1.1Principle Whenoperating,therangehoodgeneratesnoise,someofwhichisradiatedintotheroom.Themethoddescribed belowallowstodeterminetheacousticpowerlevelofthenoisethusemitted. R
37、angehoodsnotincorporatingafanshallbetestedaccordingtotheExhaustAirTerminalDevicetestmethod specifiedin5.1ofEN131412:2003. 5.1.2 Testinstallationandconditions Testinstallationandconditionsshallconformto5.1ofEN131412:2003withthefollowingarrangements: fortherecirculatingairrangehood,thecompletedevicesh
38、allbelocatedinthereverberantroomwherethe measurementsaremade.Thereshallbenoconnectionwiththesecondroom; fortheairextractionrangehood(incorporatingafan),aductwithanominallengthof1,8mshallbeconnected tothedeviceandpositionedintheadjacentreverberantroom; duetothesizeoftherangehoodanditspositioninaroomi
39、nnormaluse,thepositionoftherangehoodin/on thewallseparatingthe2reverberantroomsshallbeataminimumdistanceof1mfromallotherwalls,and preferablyawayfromanysymmetryaxisoftheroom. 5.1.3 Testprocedure Thetestshallbecarriedoutinaccordancewith5.1ofEN131412:2003. 5.1.4 Presentationofresults Theresultsshallbep
40、resentedaccordingto5.3ofEN131412:2003. 5.2Insertion loss 5.2.1Principle Thefollowingtestquantifiesthesoundattenuationthrougharangehood,theobjectivebeingtoallowthe evaluationofsoundtransmissionfromonedwellingtoanotherthroughtheventilationduct.Thistestistherefore notrequiredforrecirculatingairrangehoo
41、ds. NOTE Forarangehoodincorporatingafan,itisassumedthatwhenthefanisoperating,thenoisetransmissionisless significantthanthenoiseproductiondeterminedin5.1. 5.2.2 Testinstallationandconditions Thetestshallconformto5.2.2ofEN131412:2003.EN131413:2003(E) 8 5.2.3 Testprocedure Thetestshallbecarriedoutinacc
42、ordancewith5.2.3ofEN131412:2003. 5.2.4 Analysisofresults Analysisoftheresultsshallconformto5.2.4ofEN131412:2003. 5.2.5 Presentationofresults Theresultsshallbepresentedaccordingto5.3ofEN131412:2003. 6 Performancetestingofgreaseabsorption Thegreaseabsorptionperformanceshallbedeterminedaccordingtoclaus
43、e12ofIEC61591:1997.Forrange hoodsnotincorporatingafan,thesameprocedureshallbefollowedtakingintoaccounttheflowratespecifiedby themanufacturer. 7 Performancetestingofodourextraction Theodourextractionperformance(odourreductionfactorandodourdispersiontime)shallbedetermined accordingtoclause13ofIEC61591:1997.Forrangehoodsnotincorporatingafan,thesameprocedureshallbe followedtakingintoaccounttheflowratespecifiedbythemanufacturer. 8 Performancetestingofelectricalpower 8.1Method TheelectricalpowerforthefanmotoroftherangehoodshallbedeterminedaccordingtoISO5801. 8.2 A