1、BS EN13523-10:2010ICS 25.220.60NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDCoil coated metals Test methodsPart 10: Resistance to fluorescent UVradiation and water condensationCopyright European Committee for Standardization Provided by IHS under license with
2、 CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-This British Standardwas published under theauthority of the StandardsPolicy and StrategyCommittee on 30 June2010 BSI 2010ISBN 978 0 580 65805 1Amendments/corrigenda issued since publicationDate CommentsBS EN 1352
3、3-10:2010National forewordThis British Standard is the UK implementation of EN 13523-10:2010. Itsupersedes BS EN 13523-10:2001 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee STI/27, Paint systems for metallic substrates.A list of organizations represen
4、ted on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obligations.Copyright Europea
5、n Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13523-10:2010EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 13523-10 March 2010 ICS 25.220.60 Supersedes EN 13523-10:2001English Versio
6、n Coil coated metals - Test methods - Part 10: Resistance to fluorescent UV radiation and water condensation Tles prlaques - Mthodes dessai - Partie 10 : Rsistance un rayonnement UV fluorescent et la condensation de leau Bandbeschichtete Metalle - Prfverfahren - Teil 10: Bestndigkeit gegen UV-Strahl
7、ung mit Leuchtstofflampen und Kondensation von Wasser This European Standard was approved by CEN on 20 February 2010. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without a
8、ny alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made
9、 by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finla
10、nd, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KO
11、MITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13523-10:2010: ECopyright European Committee for Standardization Provided by IHS under license with CENNot f
12、or ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13523-10:2010EN 13523-10:2010 (E) 2 Contents Page Foreword 31 Scope 52 Normative references 53 Terms and definitions .54 Principle 55 Apparatus and materials .56 Sampling .67 Test panels .68 Procedure .68.1 Exposure
13、.68.2 Calibration and maintenance of calibration 78.3 Evaluation of test specimens .79 Expression of results 710 Precision .711 Test report 7Bibliography 8Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted with
14、out license from IHS-,-,-BS EN 13523-10:2010EN 13523-10:2010 (E) 3 Foreword This document (EN 13523-10:2010) has been prepared by Technical Committee CEN/TC 139 “Paints and varnishes”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, e
15、ither by publication of an identical text or by endorsement, at the latest by September 2010, and conflicting national standards shall be withdrawn at the latest by September 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. C
16、EN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 13523-10:2001. The main technical changes are: a) the title is changed; b) UV light is changed to UV radiation; c) black-standard temperature is changed to black-panel temperatu
17、re; d) amendments concerning the UV lamps are made; e) a clause on calibration is added. EN 13523, Coil coated metals Test methods, consists of the following parts: Part 0: General introduction and list of test methods Part 1: Film thickness Part 2: Specular gloss Part 3: Colour difference Instrumen
18、tal comparison Part 4: Pencil hardness Part 5: Resistance to rapid deformation (impact test) Part 6: Adhesion after indentation (cupping test) Part 7: Resistance to cracking on bending (T-bend test) Part 8: Resistance to salt spray (fog) Part 9: Resistance to water immersion Part 10: Resistance to f
19、luorescent UV radiation and water condensation Part 11: Resistance to solvents (rubbing test) Part 12: Resistance to scratching Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS
20、 EN 13523-10:2010EN 13523-10:2010 (E) 4 Part 13: Resistance to accelerated ageing by the use of heat Part 14: Chalking (Helmen method) Part 15: Metamerism Part 16: Resistance to abrasion Part 17: Adhesion of strippable films Part 18: Resistance to staining Part 19: Panel design and method of atmosph
21、eric exposure testing Part 20: Foam adhesion Part 21: Evaluation of outdoor exposed panels Part 22: Colour difference Visual comparison Part 23: Colour stability in humid atmospheres containing sulfur dioxide Part 24: Resistance to blocking and pressure marking Part 25: Resistance to humidity Part 2
22、6: Resistance to condensation of water Part 27: Resistance to humid poultice (Cataplasm test) Part 29: Resistance to environmental soiling (Dirt pick-up and striping) According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to imple
23、ment this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Swi
24、tzerland and the United Kingdom. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13523-10:2010EN 13523-10:2010 (E) 5 1 Scope This European Standard specifies the basic prin
25、ciples and procedure for determining the resistance of an organic coating on a metallic substrate (coil coating) to a combination of fluorescent UV radiation, and water condensation and temperature under controlled conditions. Due to varied conditions which occur during natural weathering and the ex
26、treme nature of accelerated testing, correlation between the two cannot be expected. Not all organic coatings will perform on an equal basis but a degree of correlation between the same generic type might be observed. 2 Normative references The following referenced documents are indispensable for th
27、e application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 13523-0:2001, Coil coated metals Test methods Part 0: General introduction and list of test methods EN 13
28、523-2, Coil coated metals Test methods Part 2: Specular gloss EN 13523-3, Coil coated metals Test methods Part 3: Colour difference Instrumental comparison EN 13523-14, Coil coated metals Test methods Part 14: Chalking (Helmen method) EN 13523-22, Coil coated metals Test methods Part 22: Colour diff
29、erence Visual comparison EN ISO 11507, Paints and varnishes Exposure of coatings to artificial weathering Exposure to fluorescent UV lamps and water (ISO 11507:2007) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 13523-0:2001 apply. 4 Principle The c
30、oating is exposed in a cyclic manner to UV radiation, condensation of water and temperature under controlled conditions. One of two types of fluorescent UV lamps, UVA-340 or UVB-313, are used. After exposure to UV radiation under controlled conditions chalking and changes in gloss and colour are ass
31、essed. 5 Apparatus and materials Ordinary laboratory apparatus and glassware, together with the following. 5.1 Test chamber. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN
32、 13523-10:2010EN 13523-10:2010 (E) 6 The test chamber shall be constructed of corrosion resistant materials. Enclosed within the test chamber shall be eight fluorescent lamps (5.2), a heater pan, racks for test specimens, and provisions for indicating and controlling operating times and temperatures
33、. The lamps shall be in banks of four on either side of the cabinet. Electrical operating conditions for the lamps shall be as given by the manufacturer. 5.2 UV lamps. Either UVA-340 or UVB-313, as specified in EN ISO 11507: UVA-340 starting at a wavelength of approximately 300 nm with a peak emissi
34、on at 340 nm; UVB-313 starting at a wavelength of approximately 280 nm with a peak emission at 313 nm. 5.3 Water supply. Deionized water. 6 Sampling See EN 13523-0. 7 Test panels See EN 13523-0. The test specimens shall be flat and about 150 mm 75 mm in size. NOTE Deviations from the standard method
35、s of panel shape, size, previous working, or conditioning may be agreed between the interested parties. 8 Procedure 8.1 Exposure Place the test specimens in racks which are made of inert material. Expose the face of the test specimens parallel to the lamps at a distance of about 50 mm from the neare
36、st surface of the lamp. If there are empty spaces within the racks fill these with blanks to maintain the conditions within the test chamber. Cycle the test specimens through periods of 4 h of dry UV exposure at a black panel temperature of (60 3) C, followed by a period of 4 h of water condensation
37、 exposure, without radiation, at a black panel temperature of (40 3) C. (One cycle consists of 8 h exposure.) Arrange the test specimens to allow the condensate to freely run off the surface under gravity. Conclude the exposure at an agreed time, for example 2 000 h for UVA-340 or 1 000 h for UVB-31
38、3, or an agreed number of cycles, for example 250 cycles for UVA-340 or 125 cycles for UVB-313. NOTE Where possible, use an agreed irradiance level, typically 0,89 W/m for UVA-340 or 0,71 W/m for UVB-313. Copyright European Committee for Standardization Provided by IHS under license with CENNot for
39、ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13523-10:2010EN 13523-10:2010 (E) 7 8.2 Calibration and maintenance of calibration Calibration of the UV-lamps depends on the type of weathering apparatus, whether the irradiance level can be set or not. For apparatus w
40、ithout the possibility to set the irradiance, after every usage of 400 radiation hours, replace one lamp and rotate the others within the bank with the oldest lamp being taken out of service unless otherwise specified by the equipment manufacturer. For apparatus with irradiance measurement the appar
41、atus indicates when the radiation sensors need to be calibrated. Carry out the calibration of the radiation sensors according to the method provided by the equipment manufacturer using the calibration equipment. When the irradiance of a lamp falls below the set point, it shall be replaced. This is u
42、sually triggered by an alarm on the equipment. 8.3 Evaluation of test specimens At the conclusion of the exposure evaluate the test specimens for chalking, changes of gloss and colour. Assess the coating for chalking, change of gloss and change of colour at ambient temperature. For more accurate mea
43、surements, as required for instance in case of dispute, the temperature shall be (23 2) C and the relative humidity (50 5) %, in accordance with EN 23270. 9 Expression of results The results shall be expressed as comparison between an unexposed test specimen and an exposed test specimen for properti
44、es defined in EN 13523-2, EN 13523-3, EN 13523-14 and EN 13523-22, if appropriate in terms of, for example, x % gloss retention EN 13523-2, E*b = y EN 13523-3, z chalking EN 13523-14. 10 Precision No precision data are currently available. 11 Test report The test report shall contain at least the fo
45、llowing information: a) all details necessary to identify the product tested; b) reference to this part of EN 13523 (EN 13523-10); c) type of UV lamps used; d) duration of exposure in hours (h); e) results of the test, as indicated in Clause 9; f) any deviation, by agreement or otherwise, from the t
46、est method specified; g) date(s) of the test. Copyright European Committee for Standardization Provided by IHS under license with CENNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-BS EN 13523-10:2010EN 13523-10:2010 (E) 8 Bibliography 1 EN 1396, Aluminium and alum
47、inium alloys Coil coated sheet and strip for general applications Specifications 2 EN 10169-1, Continuously organic coated (coil coated) steel flat products Part 1: General information (definitions, materials, tolerances, test methods) 3 EN 10169-2, Continuously organic coated (coil coated) steel fl
48、at products Part 2: Products for building exterior applications 4 EN 10169-3, Continuously organic coated (coil coated) steel flat products Part 3: Products for building interior applications 5 EN ISO 4892-3, Plastics Methods of exposure to laboratory light sources Part 3: Fluorescent UV lamps (ISO 4892-3:2006) 6 EN 23270, Paints and varnishes and their raw materials Temperatures and humidities for conditioning