1、BS EN 14037-1:2016Free hanging heating andcooling surfaces for water witha temperature below 120CPart 1: Pre-fabricated ceiling mountedradiant panels for space heating T e c h n i c a l s p e c i f i c a t i o n s a n d r e q u i r e m e n t sBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW
2、.indd 1 15/05/2013 15:06BS EN 14037-1:2016 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 14037-1:2016.It supersedes BS EN 14037-1:2003 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee RHE/6, Air or space heaters or
3、 coolers without com-bustion.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 20
4、16.Published by BSI Standards Limited 2016ISBN 978 0 580 90457 8ICS 91.140.10Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 30 September 2016.Amendments/corrigend
5、a issued since publicationDate T e x t a f f e c t e dBS EN 14037-1:2016EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 14037-1 September 2016 ICS 91.140.10; 91.140.30 Supersedes EN 14037-1:2003English Version Free hanging heating and cooling surfaces for water with a temperature below 120C - P
6、art 1: Pre-fabricated ceiling mounted radiant panels for space heating - Technical specifications and requirements Panneaux rayonnants de chauffage et de rafrachissement aliments avec une eau une temprature infrieure 120 C - Partie 1 : Panneaux rayonnants de plafond prfabriqus destins au chauffage d
7、es locaux - Spcifications techniques et exigences An der Decke frei abgehngte Heiz- und Khlflchen fr Wasser mit einer Temperatur unter 120 C - Teil 1: Vorgefertigte Deckenstrahlplatten zur Raumheizung - Technische Spezifikationen und Anforderungen This European Standard was approved by CEN on 19 Mar
8、ch 2016. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obta
9、ined on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CE
10、N-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland
11、, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey andUnited Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre:
12、 Avenue Marnix 17, B-1000 Brussels 2016 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 14037-1:2016 EBS EN 14037-1:2016EN 14037-1:2016 (E) 2 Contents European foreword 4 Introduction . 5 1 Scope . 6 2 Normative references . 6 3 Te
13、rms and definitions 6 4 Symbols and units . 11 5 Requirements . 13 5.1 General manufacturing requirements 13 5.2 Surface protection. 13 5.3 Materials . 14 5.4 Surface emissivity . 14 5.5 Mechanical resistance . 14 5.5.1 Horizontal curvature of radiant ceiling panels 14 5.5.2 Vertical deflection of r
14、adiant ceiling panels . 15 5.6 Resistance to fixings . 15 5.7 Pressure tightness 15 5.8 Resistance to pressure 15 5.9 Dimensional tolerances 15 5.10 Upper Insulation 16 5.11 Water flow resistance 16 5.12 Release of dangerous substances 16 5.13 Reaction to fire . 16 5.13.1 General 16 5.13.2 Free hang
15、ing heating and cooling surfaces classified as Class A1 without the need for testing 16 5.13.3 Free hanging heating and cooling surfaces classified according to the test results . 17 5.14 Rated thermal output and characteristic equation 17 5.15 Surface temperature 17 6 Assessment and verification of
16、 constancy of performance - AVCP . 17 6.1 General 17 6.2 Type testing . 17 6.2.1 General 17 6.2.2 Test samples, testing and compliance criteria . 18 6.2.3 Test reports . 19 6.2.4 Shared other party results . 19 6.3 Factory production control (FPC) . 20 6.3.1 General 20 6.3.2 Requirements . 20 6.3.3
17、Product specific requirements . 24 6.3.4 Initial inspection of factory and of FPC . 24 6.3.5 Continuous surveillance of FPC 25 6.3.6 Procedure for modifications . 25 6.3.7 One-off products, pre-production products (e.g. prototypes) and products produced in very low quantity 26 7 Technical documentat
18、ion . 27 7.1 General 27 7.2 Designation of the ceiling mounted radiant panels 27 7.3 Maximum operating pressure 27 7.4 Maximum operating temperature 27 BS EN 14037-1:2016EN 14037-1:2016 (E) 3 7.5 Thermal output respectively cooling capacity 27 7.6 Dimensions and technical data . 27 7.7 Reference dat
19、a 28 7.8 Installation manual . 28 Annex ZA (informative) Relationship of this European Standard with Regulation (EU) No. 305/2011 29 ZA.1 Scope and relevant characteristics . 29 ZA.2 System of Assessment and Verification of Constancy of Performance (AVCP) . 30 ZA.3 Assignment of AVCP tasks 30 Biblio
20、graphy 32 BS EN 14037-1:2016EN 14037-1:2016 (E) 4 European foreword This document (EN 14037-1:2016) has been prepared by Technical Committee CEN/TC 130 “Space heating appliances without integral heat sources”, the secretariat of which is held by UNI. This document supersedes EN 14037-1:2003. This Eu
21、ropean Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by March 2017, and conflicting national standards shall be withdrawn at the latest by June 2018. Attention is drawn to the possibility that some of the elemen
22、ts of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the Eu-ropean Free Trade Association, and supports basi
23、c work requirements of Regulation (EU) No. 305/2011. For relationship with Regulation (EU) No. 305/2011, see informative Annex ZA, which is an integral part of this document. The main changes are: the title has been changed, the introduction has been changed, the scope has been changed, new definiti
24、ons have been added, the Annex ZA has been adapted. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland
25、, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portu-gal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 14037-1:2016EN 14037-1:2016
26、(E) 5 Introduction This European Standard results from the recognition, that heated and chilled ceiling radiant panels falling into the field of application hereinafter stated are traded on the basis of their thermal output. For evaluating and comparing different heated and chilled ceiling surfaces
27、it is therefore necessary to refer to a heating stipulated value. As installations with ceiling mounted radiant panels can also be used in practice for space cooling, it is nec-essary to have a test method for evaluating the cooling capacity. Installations with different free hanging heating and coo
28、ling surfaces need, for the use of space heating a test method for evaluating the heating out-put. The test method differs from the method for ceiling mounted radiant panels. The European Standard EN 14037, Free hanging heating and cooling surfaces for water with a temperature below 120C, consists o
29、f the following parts: Part 1: Pre-fabricated ceiling mounted radiant panels for space heating - Technical specifications and re-quirements; Part 2: Pre-fabricated ceiling mounted radiant panels for space heating - Test method for thermal output; Part 3: Pre-fabricated ceiling mounted radiant panels
30、 for space heating - Rating method and evaluation of radiant thermal output; Part 4: Pre-fabricated ceiling mounted radiant panels for space heating - Test method for cooling capacity; Part 5: Open or closed heated ceiling surfaces - Test method for thermal output. BS EN 14037-1:2016EN 14037-1:2016
31、(E) 6 1 Scope This European Standard defines technical specifications and requirements of free hanging pre-fabricated ceiling mounted radiant panels with an air gap between construction and the emitter (not embedded) fed with water at temperatures below 120 C connected with a centralized heating sup
32、ply source intended to be installed in buildings. The panels should be installed with an upper insulation. The European Standard does not apply to independent heating devices. The European Standard also defines the additional common data that the manufacturer has to provide to the trade in order to
33、ensure the correct application of the products. This European standard does not cover the performance of hanging accessories. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indis-pensable for its application. For dated referen
34、ces, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 13501-1, Fire classification of construction products and building elements - Part 1: Classification using da-ta from reaction to fire tests EN 14037-2:20
35、16, Free hanging heating and cooling surfaces for water with a temperature below 120C Part 2: Pre-fabricated ceiling mounted radiant panels for space heating - Test method for thermal output EN 14037-3:2016, Free hanging heating and cooling surfaces for water with a temperature below 120C - Part 3:
36、Pre-fabricated ceiling mounted radiant panels for space heating - Rating method and evaluation of radiant thermal output EN ISO 2409, Paints and varnishes - Cross-cut test (ISO 2409) 3 Terms and definitions For the purposes of this document, the terms and definitions given below apply. 3.1 heating a
37、ppliance device having the purpose of transferring heat in order to provide specific temperature conditions inside buildings 3.2 independent heating appliance self-contained heating appliance which does not need to be connected to a remote heat source (e. g. a boiler) as it contains its own heat sou
38、rce (e. g. gas fired appliances, electric appliances, heat pump appliances) 3.3 pre-fabricated ceiling mounted radiant panel pre-fabricated heat-transmitting device in the form of a heating or cooling element with width of 0,3 m up to 1,5 m fitted with connection components or open pipes for in-side
39、-assembling and designed to operate on water flow heating and/or cooling facilities BS EN 14037-1:2016EN 14037-1:2016 (E) 7 3.4 model ceiling mounted radiant panel or heated ceiling surface of defined construction, e.g. width, height, number and diameter of the tubes 3.5 type group of models with id
40、entical modular cross section 3.6 sample ceiling mounted radiant panel or heated ceiling surface, used for testing 3.7 inlet water temperature bulk temperature of the water entering the ceiling mounted radiant panel 3.8 outlet water temperature bulk temperature of the water leaving the ceiling mount
41、ed radiant panel 3.9 mean water temperature arithmetical mean of inlet and outlet water temperature 3.10 water temperature drop temperature difference between the inlet and outlet water temperature of the pre-fabricated ceiling mount-ed radiant panel 3.11 mean radiant temperature temperature in a de
42、fined point of the room resulting from the radiation of all surrounding surfaces and of the pre-fabricated ceiling mounted radiant panel respectively heated ceiling surface 3.12 reference room temperature temperature measured with a globe thermometer 3.13 temperature difference temperature differenc
43、e between mean water temperature and reference room temperature 3.14 standard temperature difference of ceiling mounted radiant panels (EN 14037-2) mean water temperature 75C and reference room temperature 20C, determined temperature difference 55 K 3.15 surface temperatures of the inside surfaces o
44、f the test room mean temperatures of the inside surfaces of the test room 3.16 mean surface temperature of the pre-fabricated ceiling mounted radiant panel mean temperature on the heating or cooling surfaces of the ceiling mounted radiant panel facing the room below BS EN 14037-1:2016EN 14037-1:2016
45、 (E) 8 3.17 surface temperature maximum inlet water temperature Note 1 to entry: This definition is given for safety requirements only. 3.18 air temperature indoor air temperature measured by using radiation shields 3.19 active length of the pre-fabricated ceiling mounted radiant panel length of the
46、 usable heating and cooling panels with identical cross section and without connection compo-nents and covers, which are bonded together with the water flow components 3.20 connection components all other components attached to the active length of the ceiling mounted radiant panel which are used fo
47、r connecting to the distribution system or for venting and draining (see Figure 1) 3.21 indirect heating surface (dry surface) portion of the heating surface of the panel which is in contact with air only (e.g. radiant sheet between the tubes) 3.22 direct heating surface (wet surface) portion of the
48、 heating surface of the panel which is in contact with the water 3.23 active surface of the pre-fabricated ceiling mounted radiant panel lower panel surface, the lateral edges are not included 3.24 air pressure pressure of air measured by a barometer at the testing place 3.25 standard air pressure p
49、ressure of air which is defined as 101,325 kPa (1,01325 bar) 3.26 water flow rate amount of water flowing through the ceiling mounted radiant panel resp. heating and cooling surface, per unit of time 3.27 total thermal output thermal output of the active length and of the connection components 3.28 radiant output thermal output emitted downwards by radiation of the active length BS EN 14037-1:2016EN 14037-1:2016 (E) 9 3.29 standard thermal output thermal output at standard temperature difference, standard air pressure and upper insu