1、Aerospace series - Cables, electrical, for general purpose - Operating temperatures between -55 C and 260 CPart 010: DR family, single UV laser printable - Product standardBS EN 2267-010:2017BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06EUROPEAN STANDARD NORME EURO
2、PENNE EUROPISCHE NORM EN 2267-010 August 2017 ICS 49.060 Supersedes EN 2267-010:2013English Version Aerospace series - Cables, electrical, for general purpose - Operating temperatures between -55 C and 260 C - Part 010: DR family, single UV laser printable - Product standard Srie arospatiale - Cbles
3、, lectriques, dusage gnral - Tempratures de fonctionnement comprises entre -55 C et 260 C - Partie 010: Famille DR, fil simple marquable au laser UV - Norme de produit Luft- und Raumfahrt - Leitungen, elektrisch, fr allgemeine Verwendung - Betriebstemperaturen zwischen -55 C und 260 C - Teil 010: DR
4、-Familie Einadrige Leitungen UV-Laser bedruckbar - Produktnorm This European Standard was approved by CEN on 20 February 2017. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard
5、without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any ot
6、her language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic
7、, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EURO
8、PEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 2267-010:2017 EN
9、ational forewordThis British Standard is the UK implementation of EN 2267-010:2017. It supersedes BS EN 2267-010:2013, which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee ACE/6, Aerospace avionic electrical and fibre optic technology.A list of organization
10、s represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017 Published by BSI Standards Limited 2017ISBN 9
11、78 0 580 96345 2ICS 49.060Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 August 2017.Amendments/corrigenda issued since publicationDate Text affectedBRITISH
12、STANDARDBS EN 2267010:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 2267-010 August 2017 ICS 49.060 Supersedes EN 2267-010:2013English Version Aerospace series - Cables, electrical, for general purpose - Operating temperatures between -55 C and 260 C - Part 010: DR family, single UV laser
13、 printable - Product standard Srie arospatiale - Cbles, lectriques, dusage gnral - Tempratures de fonctionnement comprises entre -55 C et 260 C - Partie 010: Famille DR, fil simple marquable au laser UV - Norme de produit Luft- und Raumfahrt - Leitungen, elektrisch, fr allgemeine Verwendung - Betrie
14、bstemperaturen zwischen -55 C und 260 C - Teil 010: DR-Familie Einadrige Leitungen UV-Laser bedruckbar - Produktnorm This European Standard was approved by CEN on 20 February 2017. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving thi
15、s European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official v
16、ersions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austr
17、ia, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain
18、, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by any means reserved worldwide
19、for CEN national Members. Ref. No. EN 2267-010:2017 EBS EN 2267010:2017EN 2267-010:2017 (E) 2 Contents Page European foreword 3 1 Scope 4 2 Normative references 4 3 Terms, definitions, symbols and abbreviations . 4 4 Materials and construction . 5 5 Required characteristics 6 6 Quality assurance 9 7
20、 Designation . 9 8 Identification and marking 10 9 Packaging, labelling and delivery lengths 10 10 Technical specification . 10 BS EN 2267010:2017EN 2267-010:2017 (E) 3 European foreword This document (EN 2267-010:2017) has been prepared by the Aerospace and Defence Industries Association of Europe
21、- Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this European Standard has received the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This Europea
22、n Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2018, and conflicting national standards shall be withdrawn at the latest by February 2018. Attention is drawn to the possibility that some of the elem
23、ents of this document may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 2267-010:2013. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries ar
24、e bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Po
25、rtugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 2267010:2017EN 2267-010:2017 (E) 4 1 Scope This European Standard specifies the characteristics of UV laser printable electrical lightweight wires DR family for use in the on-board 115 V (ph
26、ase to neutral) or 200 V (phase to phase) AC electrical systems of aircraft at operating temperatures between 65 C and 260 C. These cables are demonstrated to be arc resistant in sizes AWG 26 to 14 (115/200 V AC). In addition, these cables may be suitable for use at 230/400 V AC in pressurised zones
27、 only when installed to take account of possible short circuit effects. It shall also be possible to mark these cables by qualified compatible marking. These markings shall satisfy the requirements of EN 3838. 2 Normative references The following documents, in whole or in part, are normatively refer
28、enced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2083, Aerospace series Copper and copper alloys conductors for electric
29、al cables Product standard EN 2084, Aerospace series Cables, electrical, general purpose, with conductors in copper or copper alloy Technical specification EN 2267-002, Aerospace series Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 002: General EN 3475 (a
30、ll parts), Aerospace series Cables, electrical, aircraft use Test methods EN 3838, Aerospace series Requirements and tests on user-applied markings on aircraft electrical cables EN 4434, Aerospace series Copper or copper alloy lightweight conductors for electrical cables Product standard (Normal and
31、 tight tolerances) EN 9133, Aerospace series Quality management systems - Qualification procedure for aerospace standard parts TR 6058, Aerospace series Cable code identification list 1)3 Terms, definitions, symbols and abbreviations For the purposes of this document, the terms, definitions, symbols
32、 and abbreviations given in EN 3475-100 apply. 1) Published as ASD-STAN Technical Report at the date of publication of this European Standard by AeroSpace and Defence industries Association of Europe - Standardization (ASD-STAN) (www.asd-stan.org) BS EN 2267010:2017EN 2267-010:2017 (E) 5 4 Materials
33、 and construction 4.1 Materials Conductor: These cable conductors shall be made of copper or copper alloy and nickel plated according to EN 4434 code D. Insulation: For all sizes codes shall be defined to satisfy all required characteristics of Clause 5. For single core, it shall be possible to mark
34、 the outer layer of the insulation by UV laser printing. 4.2 Construction See EN 4434 and Table 1. Table 1 Code for nominal section Nominal section AWG a Linear resistance at 20 C External diameter Mass mm2/km mm kg/km max. min. max. max. 001 0,15 26 160,0 0,75 0,84 2,08 002 0,25 24 114,0 0,85 0,96
35、2,72 004 0,4 22 60,0 1,00 1,10 4,14 006 0,6 20 33,2 1,22 1,34 6,85 010 1 18 21,1 1,46 1,61 10,43 012 1,2 16 14,5 1,76 1,92 14,61 020 2 14 10,9 2,04 2,24 19,78 030 3 12 6,8 2,50 2,70 31,33 051 5 10 4,1 3,13 3,33 49,85 090 9 8 2,3 4,10 4,40 90,00 140 14 6 1,58 5,30 5,70 135,00 220 22 4 0,97 6,71 7,41
36、222,00 340 34 2 0,61 8,28 9,16 347,00 a AWG = closest American Wire Gage.4.3 Number of cores See EN 2267-002. BS EN 2267010:2017EN 2267-010:2017 (E) 6 4.4 Colour coding of cores See EN 2267-002. 5 Required characteristics According to EN 2084 and EN 3475-100. See Table 2. Table 2 (1 of 4) EN 3475- D
37、esignation of the test Details 201 Visual examination Applicable including laser marked specimen 202 Mass Applicable, see Table 1. 203 Dimensions Applicable, see Table 1. 301 Ohmic resistance per unit length Applicable, see Table 1. 302 Voltage proof test Applicable 303 Insulation resistance Applica
38、ble 304 Surface resistance Applicable 305 Overload resistance Applicable T1 = (310 5) C; T2 = (450 5) C 306 Continuity of conductors Applicable 307 Corona extinction voltage Not applicable 401 Accelerated ageing Applicable including laser marked specimen Temperature (310 5) C 402 Shrinkage and delam
39、ination Applicable Temperature (290 5) C Maximum shrinkage at each end of cable: 0,15 mm2to 0,60 mm2: 0,80 mm; 1,00 mm2to 1,20 mm2: 1,00 mm; 2,00 mm2to 5,00 mm2: 1,20 mm; 9,00 mm2: 1,50 mm; 14,00 mm2: 2,00 mm. 403 Delamination and blocking Applicable Temperature (310 5) C 404 Thermal shock Applicabl
40、e Temperature (260 5) C and ( 65 2) C Maximum shrinkage at each end of cable: 0,15 mm2to 0,60 mm2: 0,80 mm; 1,00 mm2to 1,20 mm2: 1,00 mm; 2,00 mm2to 5,00 mm2: 1,20 mm; 9,00 mm2: 1,50 mm; 14,00 mm2: 2,00 mm. BS EN 2267010:2017EN 2267-010:2017 (E) 7 Table 2 (2 of 4) EN 3475- Designation of the test De
41、tails 405 Bending at ambient temperature Applicable including laser marked specimen 406 Cold bend test Applicable Temperature ( 65 2) C 407 Flammability Applicable Extinguishing time: 3 s max. 408 Fire resistance Not applicable 409 Air-excluded ageing Not applicable 410 Thermal endurance Applicable
42、10 000 h at 260 C with curve extrapolation 100 000 h at 200 C with curve reading 411 Resistance to fluids Applicable including laser marked specimens 412 Humidity resistance Applicable Method B Temperature (95 5) C Duration 360 h 413 Wrap back test Applicable 414 Differential scanning calorimeter (D
43、SC test) Applicable (only if PTFE in the construction) 415 Rapid change of temperature Not applicable 416 Thermal stability Not applicable 501 Dynamic cut-through Applicable Temperatures (20 3) C and (260 5) C Nominal section Cut-through force 20 C 260 C mm2N N 0,15 70 15 0,25 85 30 0,40 110 45 0,60
44、 140 55 1,00 140 70 1,20 150 85 2,00 150 95 3,00 165 105 5,00 180 120 9,00 195 135 14,00 210 150 BS EN 2267010:2017EN 2267-010:2017 (E) 8 Table 2 (3 of 4) EN 3475- Designation of the test Details 502 Notch propagation Applicable Notch depth: 40 m 503 Scrape abrasion Applicable Test force on needle f
45、or cables: 0,15 mm2= 5 N; 0,25 mm2to 0,60 mm2= 8 N; 1,00 mm2to 1,20 mm2= 10 N; 2,00 mm2to 9,00 mm2= 12 N; 14,00 mm2= 15 N. 504 Torsion Applicable T3 = (260 5) C; T4 = (310 5) C 505 Tensile test on conductors and strands Applicable 506 Plating continuity Applicable 507 Adherence of plating Applicable
46、 508 Plating thickness Applicable 509 Solderability Not applicable 510 Tensile strength and elongation of extruded insulation, sheath and jacket material Not applicable 511 Cable-to-cable abrasion Applicable code 006 0,6 mm2, weight 25 N 2 800 000 cycles 512 Flexure endurance Applicable code 006 0,6
47、 mm2, mandrel diameter 15 mm Weight 9 N 1 000 cycles 513 Deformation resistance (Installation with plastic cable ties) Not applicable 601 Smoke density Applicable 602 Toxicity Applicable 603 Resistance to wet arc tracking Applicable code 006 Test voltage 115/200 V AC Wire damage maximum 70 mm; 75 %
48、of collateral wires must pass the wet dielectric voltage proof test EN 3475-302. Applicable code 006 Test voltage 230/400 V AC Wire damage maximum 70 mm. 604 Resistance to dry arc propagation Applicable Test voltage 115/200 V AC Wire damage maximum 70 mm; 75 % of collateral wires must pass the wet d
49、ielectric voltage proof test EN 3475-302. Applicable Test voltage 230/400 V AC Wire damage maximum 70 mm. 605 Wet short circuit test Applicable Test voltage 115/200 V AC and 230/400 V AC Wire damage maximum 70 mm. 701 Strippability and adherence of insulation to the conductor Applicable BS EN 2267010:2017EN 2267-010:2017 (E) 9 Table 2 (4 of 4) EN 3475- Designation of the test Details 702 Scree