1、BRITISH STANDARDBS EN 2591-224:2007Aerospace series Elements of electrical and optical connection Test methods Part 224: RF leakageICS 49.060g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g6
2、0g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 2591-224:2007This British Standard was published under the authority of the Standards Policy and Strategy Committee on 29 February 2008 BSI 2008ISBN 978 0 580 56478 9National forewordThis British Standard is the UK implementation of EN 2591-224:2007.The
3、 UK participation in its preparation was entrusted by Technical Committee ACE/6, Aerospace avionic electrical and fibre optic technology, to Panel ACE/6/-/3, Aerospace Connectors.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does n
4、ot purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments/corrigenda issued since publicationDate CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE N
5、ORMEN 2591-224December 2007ICS 49.060English VersionAerospace series - Elements of electrical and optical connection- Test methods - Part 224: RF leakageSrie arospatiale - Organes de connexion lectrique etoptique - Mthodes dessais - Partie 224: Fuite HFLuft- und Raumfahrt - Elektrische und optischeV
6、erbindungselemente - Prfverfahren - Teil 224: HF-StreuverlustThis European Standard was approved by CEN on 27 April 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without
7、 any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made
8、 by translationunder the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, G
9、ermany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGM
10、anagement Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 2591-224:2007: E2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Preparation of specimens.4 4 Apparatus .6 5 Met
11、hod 6 6 Results 6 EN 2591-224:20073 Foreword This document (EN 2591-224:2007) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has receiv
12、ed the approval of the National Associations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by June 2008,
13、and conflicting national standards shall be withdrawn at the latest by June 2008. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. Acco
14、rding to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latv
15、ia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 2591-224:20074 1 Scope This standard specifies a test method of measuring the total RF leakage of wired coaxial connectors. It shall be used tog
16、ether with EN 2591-100. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN
17、 2591-100, Aerospace series Elements of electrical and optical connection Test methods Part 100: General. 3 Preparation of specimens The mating connector pair to be tested shall be assembled as shown on Figure 2 and tested as shown on Figure 1. Detail of Test assembly shall conform to Figure 3. Key
18、1 RF source 2 Triaxial test set up. 3 Sensitive calibrated microwave receiver Figure 1 RF leakage set-up EN 2591-224:20075 Key 1 See Figure 3. 2 Self contained termination for inner conductor (VSWR 1,30) 3 High performance connector to RF detector 4 Travel of short must exceed /2 5 High performance
19、connector from RF source 6 Push rods or devices for adjusting position of short 7 Brass tubing Figure 2 Key 1 Metal to metal contact 2 Brass tubing forming a continuous shielding (external conductor of triaxial assembly) Figure 3 Mated connector pair 7 7EN 2591-224:20076 4 Apparatus Mounting of spec
20、imens The close fitting brass tubing shall be machined to thread into connector in lieu of compression nut or any device, which insure the coaxial braid connection. This test set-up between 500 MHz and 11 GHz shall have a dynamic range from 20 dBm to 100 dBm. Using an additional RF source amplifier
21、(e.g. 20 dB), increase total dynamic range. The shorting plunger is adjusted to produce a maximum reading in the detector with the triaxial assembly inserted. 5 Method The insertion loss caused by the insertion of the triaxial assembly adjusted as shown in a measure of total leakage of the mated con
22、nector pair both at its interface as well as the clamping points at both cable ends. The short circuit position is adjusted to assure that adequately low impedance appears behind the equivalent leakage generator. The characteristic impedance of the outer coaxial line of the triaxial system, which is
23、 formed with the inner conductor, should be matched to the detector, 50 coaxial circuits are generally desired for convenience. 6 Results The leakage power ratio is defined as the ratio of the power detected to a detector at the output of the triaxial unit to the power flowing through the internal f
24、lowing power (also through a 50 load). The relative leakage is the ratio: 1221IEZ = where E2is equivalent leakage voltage in external line; I1is the current flowing in internal line. The value must be under the requirement given in the product standard. The insertion loss caused by the insertion of
25、the triaxial assembly adjusted as shown is a measure of the total leakage of the mated connector pair both at its interface as well as at the clamping points to both cables. EN 2591-224:2007blankBS EN 2591-224:2007BSI389 Chiswick High RoadLondonW4 4ALBSI British Standards InstitutionBSI is the indep
26、endent national body responsible for preparing British Standards. It presents the UK view on standards in Europe and at the international level. It is incorporated by Royal Charter.RevisionsBritish Standards are updated by amendment or revision. Users of British Standards should make sure that they
27、possess the latest amendments or editions.It is the constant aim of BSI to improve the quality of our products and services. We would be grateful if anyone finding an inaccuracy or ambiguity while using this British Standard would inform the Secretary of the technical committee responsible, the iden
28、tity of which can be found on the inside front cover. Tel: +44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.BSI offers members an individual updating service called PLUS which ensures that subscribers automatically receive the latest editions of standards.Buying standardsOrders for all BSI, internation
29、al and foreign standards publications should be addressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 8996 7001. Email: ordersbsi-. Standards are also available from the BSI website at http:/www.bsi-.In response to orders for international standards, it is BSI policy to supply the
30、 BSI implementation of those that have been published as British Standards, unless otherwise requested.Information on standardsBSI provides a wide range of information on national, European and international standards through its Library and its Technical Help to Exporters Service. Various BSI elect
31、ronic information services are also available which give details on all its products and services. Contact the Information Centre. Tel: +44 (0)20 8996 7111. Fax: +44 (0)20 8996 7048. Email: infobsi-.Subscribing members of BSI are kept up to date with standards developments and receive substantial di
32、scounts on the purchase price of standards. For details of these and other benefits contact Membership Administration. Tel: +44 (0)20 8996 7002. Fax: +44 (0)20 8996 7001. Email: membershipbsi-.Information regarding online access to British Standards via British Standards Online can be found at http:
33、/www.bsi- information about BSI is available on the BSI website at http:/www.bsi-.CopyrightCopyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of the publications of the international standardization bodies. Except as permitted under the Copyright, Designs and Patent
34、s Act 1988 no extract may be reproduced, stored in a retrieval system or transmitted in any form or by any means electronic, photocopying, recording or otherwise without prior written permission from BSI.This does not preclude the free use, in the course of implementing the standard, of necessary de
35、tails such as symbols, and size, type or grade designations. If these details are to be used for any other purpose than implementation then the prior written permission of BSI must be obtained.Details and advice can be obtained from the Copyright & Licensing Manager. Tel: +44 (0)20 8996 7070. Fax: +44 (0)20 8996 7553. Email: copyrightbsi-.
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1