1、BS EN 4165-025:2017Aerospace series Connectors, electrical,rectangular, modular Operating temperature 175 CcontinuousPart 025: Single module receptacle Product standardBSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 4165-025:2017 BRITISH STANDARDNational forewo
2、rdThis British Standard is the UK implementation of EN 4165-025:2017.It supersedes BS EN 4165-025:2011 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee ACE/6, Aerospace avionic electrical and fibre optictechnology.A list of organizations represented on t
3、his committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2017. Published by BSI Standards Limited 2017ISBN 978 0 580 95146 6ICS
4、49.060Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 March 2017.Amendments/corrigenda issued since publicationDate Text affectedBS EN 4165-025:2017EUROPEAN STA
5、NDARD NORME EUROPENNE EUROPISCHE NORM EN 4165-025 February 2017 ICS 49.060 Supersedes EN 4165-025:2011English Version Aerospace series - Connectors, electrical, rectangular, modular - Operating temperature 175 C continuous - Part 025: Single module receptacle - Product standard Srie Arospatiale - Co
6、nnecteurs lectriques rectangulaires, modulaires - Temprature dutilisation 175 C continu - Partie 025 : Embase mono-module - Norme de produit Luft- und Raumfahrt - Elektrischer Rechtecksteckverbinder in modularer Bauweise - Betriebstemperatur 175 C konstant - Teil 025: Fester Steckverbinder fr Einzel
7、modul - Produktnorm This European Standard was approved by CEN on 26 October 2016. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and
8、 bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the r
9、esponsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav
10、 Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUR
11、OPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 4165-025:2017 EBS EN 4165-025:2017EN 4165-025:2017 (E) 2 Con
12、tents Page European foreword . 3 1 Scope 4 2 Normative references 4 3 Terms and definitions . 4 4 Required characteristics 4 5 Designation. 26 6 Marking 27 7 Technical specification . 27 8 Mounting example . 28 BS EN 4165-025:2017EN 4165-025:2017(E) 3 European foreword This document (EN 4165-025:201
13、7) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Associations and the Official Services of t
14、he member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by September 2017, and conflicting national standards shall be withdrawn at the latest by
15、 September 2017. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 4165-025:2011. According to the CEN-CENEL
16、EC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Ice
17、land, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 4165-025:2017EN 4165-025:2017 (E) 4 1 Scope This European Standard defines the single module recept
18、acle used in the family of rectangular electrical connectors. The plug corresponding to this receptacle is defined in EN 4165-024. Accessories and protective cover corresponding to those plugs are defined in EN 4165-026. The cavity of this connector is uncoded, so it can accept polarized modules N,
19、A, B, C and D as defined in EN 4165-002. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the
20、 referenced document (including any amendments) applies. EN 2424, Aerospace series Marking of aerospace products EN 4165-001, Aerospace series Connectors, electrical, rectangular, modular Operating temperature 175 C continuous Part 001: Technical specification EN 4165-002, Aerospace series Connector
21、s, electrical, rectangular, modular Operating temperature 175 C continuous Part 002: Specification of performance and contact arrangements EN 4165-018, Aerospace series Connectors, electrical, rectangular, modular Operating temperature 175 C continuous Part 018: Protective cover for all receptacles
22、series 2 Product standard EN 4165-024, Aerospace series Connectors, electrical, rectangular, modular Operating temperature 175 C continuous Part 024: Single module plug Product standard EN 4165-026, Aerospace series Connectors, electrical, rectangular, modular Operating temperature 175 C continuous
23、Part 026: Accessories for single module connector Product standard 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 4165-001 apply. 4 Required characteristics 4.1 Single module flange receptacle design (short receptacle) Type 0 Dimensions, alternative
24、design and positions of keying polarization, see Clause 5. See Figures 1, 2, 3 and 4. Dimensions are in millimetres. Mass = 6 g max. BS EN 4165-025:2017EN 4165-025:2017(E) 5 Figure 1 With alternatives designs BS EN 4165-025:2017EN 4165-025:2017 (E) 6 Detail A Figure 2 With alternatives designs BS EN
25、 4165-025:2017EN 4165-025:2017(E) 7 Figure 3 With alternatives designs BS EN 4165-025:2017EN 4165-025:2017 (E) 8 Figure 4 With alternatives designs BS EN 4165-025:2017EN 4165-025:2017(E) 9 4.2 Single module jack receptacle (extender) design (long receptacle) Type 7 Dimensions and positions of keying
26、 polarizations, see Clause 5. See Figures 5, 6, 7, 8 and 9. Dimensions are in millimetres. Mass = 7,5 g max. Figure 5 With alternatives designs BS EN 4165-025:2017EN 4165-025:2017 (E) 10 Figure 6 With alternatives designs BS EN 4165-025:2017EN 4165-025:2017(E) 11 Detail A Figure 7 With alternatives
27、designs BS EN 4165-025:2017EN 4165-025:2017 (E) 12 Figure 8 With alternatives designs BS EN 4165-025:2017EN 4165-025:2017(E) 13 Key 1 Orientation module 2 Index for rear accessory Figure 9 With alternatives designs BS EN 4165-025:2017EN 4165-025:2017 (E) 14 4.3 Single module extender rear accessory
28、attachment design for Type 7 only Dimensions and positions of keying polarizations, see Clause 5. See Figures 10, 11 and 12. Dimensions are in millimetres. Figure 10 With alternatives designs BS EN 4165-025:2017EN 4165-025:2017(E) 15 Key 1 Cavity 2 2 on flats Figure 11 With alternatives designs BS E
29、N 4165-025:2017EN 4165-025:2017 (E) 16 Figure 12 With alternatives designs BS EN 4165-025:2017EN 4165-025:2017(E) 17 4.4 Class See Table 1. Table 1 Class Description M Receptacle with housing (shell) nickel plated, composite material, 500 h resistance to salt mist, maximum operating temperature 175
30、C continuous 4.5 Panel cut out See Figures 13, 14, 15, 16, 17, 18, 19 and 20. Free cut out is all receptacles whatever polarization, see Figure 14. Orientation cut out is for all receptacles whatever polarization but provide 180 orientation, see Figure 15. Other Figure 16 to Figure 20 provides polar
31、ized panel cut out. Dimensions are in millimetres. Figure 13 Panel cut out general dimensions BS EN 4165-025:2017EN 4165-025:2017 (E) 18 Figure 14 Free mounting cut out dimensions Figure 15 Oriented panel cut out dimensions BS EN 4165-025:2017EN 4165-025:2017(E) 19 Polarization N Polarization A Figu
32、re 16 Detail keying dimensions for N and A panel cut out Polarization B Polarization C Figure 17 Detail keying dimensions for B and C panel cut out BS EN 4165-025:2017EN 4165-025:2017 (E) 20 Polarization D Polarization E Figure 18 Detail keying dimensions for D and E panel cut out Polarization F Pol
33、arization G Figure 19 Detail keying dimensions for F and G panel cut out BS EN 4165-025:2017EN 4165-025:2017(E) 21 Polarization H Figure 20 Detail keying dimensions for H panel cut out 4.6 Additional parts 4.6.1 Colour coding plate (Type code C) Colour according to polarization, see 5.2. See Figures
34、 21, 22, 23, 24, 25 and 26. Dimensions are in millimetres. Mass = 1,2 g max. Key 1 Four holes 2,93,1Figure 21 Panel cut out general dimensions BS EN 4165-025:2017EN 4165-025:2017 (E) 22 Polarization N Polarization A Figure 22 Detail keying dimensions for N and A colour coding plate Polarization B Po
35、larization C Figure 23 Detail keying dimensions for B and C colour coding plate BS EN 4165-025:2017EN 4165-025:2017(E) 23 Polarization D Polarization E Figure 24 Detail keying dimensions for D and E colour coding plate Polarization F Polarization G Figure 25 Detail keying dimensions for F and G colo
36、ur coding plate BS EN 4165-025:2017EN 4165-025:2017 (E) 24 Polarization H Figure 26 Detail keying dimensions for H colour coding plate 4.6.2 Nut plate (Type code D) See Figure 27. Dimensions are in millimetres. Material: Stainless steel. Mass = 1 g max. Key 1 Four threads for screw 4-40 UNC-2A Figur
37、e 27 BS EN 4165-025:2017EN 4165-025:2017(E) 25 4.6.3 Sealing gasket (Type code E) See Figure 28. Dimensions are in millimetres. Material: Silicone elastomer. Mass = 0,8 g max. Figure 28 BS EN 4165-025:2017EN 4165-025:2017 (E) 26 5 Designation 5.1 Designation of receptacle EXAMPLE Description block E
38、LECTRICAL CONNECTOR RECEPTACLE Identity block EN4165 M 7 1 A N Not marked on product 0 G 0 Number of the basic standard Classes type, see 4.4 M = composite nickel plated Shell type, see EN 4165-002 0: short receptacle (see EN 4165-002) 7: extender receptacle Shells type 1 = Mono module Type A = Modu
39、le type series 2 (see EN 4165-002) Polarization code Code Colour N Black A Red B Blue C Green D Yellow E Pink F Clear green G Clear grey H Light olive Keying colour coding plate 0 Not included 1 Included Sealing gasket U Without sealing gasket G Delivered with sealing gasket Nut plate 0 Without nut
40、plate 1 Delivered with integrated rear nut plate Receptacle may be delivered with or without keying colour coding plate, sealing gasket, and nut plate. The full reference containing last three digits is only marked on packaging. BS EN 4165-025:2017EN 4165-025:2017(E) 27 5.2 Designation of colour cod
41、ing plate EXAMPLE Description block COLOUR CODING PLATE Identity block EN4165-25 C N Number of the basic standard Type code C colour plate (see Figures 21 to 26) Polarization code Code Colour N Black A Red B Blue C Green D Yellow E Pink F Clear green G Clear grey H Light olive 5.3 Designation of nut
42、 plate EXAMPLE Description block NUT PLATE Identity block EN4165-25 D Type code D (see Figure 27) 5.4 Designation of sealing gasket EXAMPLE Description block SEALING GASKET Identity block EN4165-25 E Type code E (see Figure 28) 6 Marking Unless there are other specific contractual requirements, the
43、marking shall be in accordance with EN 2424, category P. 7 Technical specification See EN 4165-001. BS EN 4165-025:2017EN 4165-025:2017 (E) 28 8 Mounting example See Figure 29. Key 1 Receptacle 2 Colour coding plate (option) 3 Sealing gasket 4 Nut plate (option) 5 Screw (not delivered) 6 Panel (up to 2 mm thick.) Figure 29
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有