1、Sanitary tapware - Automatic shut-off valves PN 10BS EN 816:2017BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 816 August 2017 ICS 23.060.01; 91.140.70 Supersedes EN 816:1996English Version Sanitary tapware - Auto
2、matic shut-off valves PN 10 Robinetterie sanitaire - Robinets fermeture automatique PN 10 Sanitrarmaturen - Selbstschlussarmaturen PN 10 This European Standard was approved by CEN on 24 April 2017. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditio
3、ns for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in
4、 three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standard
5、s bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia,
6、 Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by any means res
7、erved worldwide for CEN national Members. Ref. No. EN 816:2017 ENational forewordThis British Standard is the UK implementation of EN 816:2017. It supersedes BS EN 816:1997, which is withdrawn.The UK participation in its preparation was entrusted to Technical Committee B/504, Water supply.A list of
8、organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2017 Published by BSI Standards Limite
9、d 2017ISBN 978 0 580 91266 5ICS 91.140.70Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2017.Amendments/corrigenda issued since publicationDate Tex
10、t affectedBRITISH STANDARDBS EN 816:2017EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 816 August 2017 ICS 23.060.01; 91.140.70 Supersedes EN 816:1996English Version Sanitary tapware - Automatic shut-off valves PN 10 Robinetterie sanitaire - Robinets fermeture automatique PN 10 Sanitrarmaturen
11、 - Selbstschlussarmaturen PN 10 This European Standard was approved by CEN on 24 April 2017. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date
12、 lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation u
13、nder the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia,Finland, Former
14、 Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION
15、COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2017 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 816:2017 EBS EN 816:2017EN 816:2017 (E) 2 Contents
16、Page European foreword 4 Introduction 5 1 Scope 6 2 Normative references 6 3 Terms and definitions . 7 4 Designation . 7 5 Marking - Identification 7 5.1 Marking 7 5.2 Identification 8 6 Materials 8 6.1 Chemical and hygienic characteristics 8 6.2 Exposed surface condition and quality of coating 8 7
17、Backflow protection . 8 8 Dimensional characteristics . 8 8.1 General 8 8.2 Tap with visible body for horizontal surfaces (see Figure 1 and Table 3) . 9 8.3 Taps with visible body for mounting on vertical surfaces (see Figure 2 and Table 4) 10 8.4 In-line tapware with threaded inlet and outlet . 10
18、8.4.1 Inlets and outlets aligned (see Figure 3 and Table 5) 10 8.4.2 Inlets and outlets at right angles (see Figure 4 and Table 5) 11 8.5 Concealed tapware for vertical surfaces 11 8.6 Mixer for horizontal surface (see Figures 5, 6 and 7 and Table 6) . 12 8.7 Mixer with visible body for mounting on
19、vertical surfaces . 16 8.7.1 Mixers with parallel inlets . 16 8.7.2 Mixer with opposed inlets (see Figure 11 and Table 5) 18 8.8 Nozzle outlets for use with flow rate regulators . 18 8.9 Special cases . 18 8.9.1 Special taps and mixers for installation on horizontal surfaces 18 8.9.2 Special taps an
20、d mixers for installation on vertical surfaces . 19 9 Leaktightness characteristics . 19 9.1 General 19 9.2 Leaktightness tests . 19 9.2.1 Principle . 19 9.2.2 Apparatus 19 9.2.3 Leaktightness of tapware upstream of the obturator . 19 9.2.4 Leaktightness of tapware downstream of the obturator with t
21、he obturator open 20 9.3 Summary of the leaktightness tests . 21 10 Pressure resistance characteristics . 22 10.1 General 22 10.2 Test of mechanical behaviour 22 10.2.1 Principle . 22 10.2.2 Apparatus 22 BS EN 816:2017EN 816:2017 (E) 3 10.2.3 Test of the mechanical behaviour upstream of the obturato
22、r, with the obturator in the closed position . 22 10.2.4 Test of mechanical behaviour downstream of the obturator, with the obturator in the open position 22 10.3 Summary of the pressure tests 23 11 Hydraulic characteristics . 23 11.1 General . 23 11.2 Test method 23 11.2.1 Principle . 23 11.2.2 Tes
23、t apparatus . 23 11.2.3 Mounting of single self-closing taps . 26 11.2.4 Mounting of mixers (see Figures 14 a), 14 b) and 14 c) 26 11.3 Principle of the flow test 27 11.4 Requirements . 28 11.4.1 Flow rate 28 11.4.2 Flow rate curve 28 11.4.3 Flow duration . 28 11.4.4 Specific characteristics of mixe
24、rs . 29 11.4.5 Testing at minimum pressure 31 12 Mechanical properties - Operating force . 31 12.1 General . 31 12.2 Procedure 31 12.3 Requirement . 31 13 Mechanical endurance or wear resistance characteristics . 31 13.1 General . 31 13.2 Procedure 31 13.3 Cycle for a single tap 32 13.4 Cycle for a
25、mixer 32 13.5 Minimum requirements . 32 14 Acoustic characteristics . 33 14.1 General . 33 14.2 Procedure 33 14.2.1 Fitting and operating conditions for tapware 33 14.2.2 Test method 33 14.3 Requirements . 33 14.3.1 Expression of the results 33 14.3.2 Determination of the acoustic group . 33 14.3.3
26、Flow class . 34 Annex A (normative) Pressure take off tees 35 Annex B (informative) Acoustic classification (example) . 37 B.1 Tapware with nozzle . 37 B.2 Tapware with shower head outlet 37 B.3 Tapware with nozzle and shower or shower head outlet 37 BS EN 816:2017EN 816:2017 (E) 4 European foreword
27、 This document (EN 816:2017) has been prepared by Technical Committee CEN/TC 164 “Water supply”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February
28、 2018, and conflicting national standards shall be withdrawn at the latest by February 2018. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN shall not be held responsible for identifying any or all such patent rights. This doc
29、ument supersedes EN 816:1996. The main changes compares to the previous edition are: 1) water saving criteria were introduced; 2) the entire structure of the standard was revised; 3) normative references have been updated; 4) editorial changes and have been made throughout the entire document; 5) fi
30、gures were redrawn. According to the CEN-CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Ma
31、cedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 816:2017EN 816:2017 (E) 5 Introduction In respect of
32、potential adverse effects on the quality of water intended for human consumption, caused by the product covered by this standard: 1) this standard provides no information as to whether the product may be used without restriction in any of the Member States of the EU or EFTA; 2) it should be noted th
33、at, while awaiting the adoption of verifiable European criteria, existing national regulations concerning the use and/or the characteristics of this product remain in force. BS EN 816:2017EN 816:2017 (E) 6 1 Scope This European Standard is applicable to single and mixer taps with automatic shut-off
34、for use with sanitary appliances installed in washrooms. It does not apply to urinal or WC flushing valves or valves which open automatically. The purpose of this standard is to specify the marking, identification, chemical/hygiene, dimensional, leaktightness, pressure resistance, hydraulic, mechani
35、cal endurance, and acoustical characteristics of automatic shut-off tapware. The tests described in all the standard are type tests (laboratory tests) and not quality control tests carried out during manufacture The conditions of pressure and temperature given in Table 1 apply: Table 1 Conditions fo
36、r the use of self-closing tapware (The pressures given are flow pressures) Limits of use Recommended limits of operation Dynamic pressure 0,05 MPa (0,5 bar) min. 0,1 MPa P 0,5 Mpa (1 bar P 5 bar) Static pressure 1 MPa (10 bar) max Hot water temperature Max 90 C 55 C T 65 C Cold water temperature - T
37、 25 C 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any
38、 amendments) applies. EN 246, Sanitary tapware - General specifications for flow rate regulators EN 248, Sanitary tapware - General specification for electrodeposited coatings of Ni-Cr EN 1717, Protection against pollution of potable water in water installations and general requirements of devices t
39、o prevent pollution by backflow EN 13618, Flexible hose assemblies in drinking water installations - Functional requirements and test methods EN 13959, Anti-pollution check valves - DN 6 to DN 250 inclusive family E, type A, B, C and D EN ISO 228-1, Pipe threads where pressure-tight joints are not m
40、ade on the threads - Part 1: Dimensions, tolerances and designation (ISO 228-1) EN ISO 3822-1, Acoustics - Laboratory tests on noise emission from appliances and equipment used in water supply installations - Part 1: Method of measurement (ISO 3822-1) EN ISO 3822-2, Acoustics - Laboratory tests on n
41、oise emission from appliances and equipment used in water supply installations - Part 2: Mounting and operating conditions for draw-off taps and mixing valves (ISO 3822-2) BS EN 816:2017EN 816:2017 (E) 7 EN ISO 3822-4:1997, Acoustics - Laboratory tests on noise emission from appliances and equipment
42、 used in water supply installations - Part 4: Mounting and operating conditions for special appliances (ISO 3822-4:1997) EN ISO 5167 (all parts), Measurement of fluid flow by means of orifice plates, nozzles and venturi tubes inserted in circular cross section conduits running full (ISO 5167) 3 Term
43、s and definitions For the purposes of this document, the following terms and definitions apply. 3.1 automatic shut-off tapware tapware in which opening is effected by operation of a device following which shut-off occurs automatically mechanical after a certain period or volume Note 1 to entry: This
44、 period and /or volume may be adjustable by the manufacturer or installer. 4 Designation An automatic shut-off tapware is designated according to Table 2: Table 2 Designation Tapware Type of valve Mechanical self-closing tap Intended use Basin, sink or shower Nominal size 1/2, 3/4; male or female Bo
45、dy Single or multi-hole; visible, or concealed Mounting method Horizontal or vertical surfaces Type of outlet Fixed, moveable, spout, with or without flow rate regulator Acoustic group and classification Group I, or group II, or unclassified Water saving properties Yes / no Flow rate class Z, A, S,
46、B, C, D Reference to this European Standard EN 816 EXAMPLE Mechanical self-closing basin tap 1/2 , single visible body, horizontal surface, fixed nozzle outlet, group I, class A EN 816. 5 Marking - Identification 5.1 Marking Tapware complying with this standard shall be permanently and indelibly mar
47、ked on the body with the manufacturers name or identification mark, and if applicable, the acoustic group and flow rate class. BS EN 816:2017EN 816:2017 (E) 8 5.2 Identification a) The control devices of single taps shall be identified by colour (for cold water by the colour blue; and for hot water,
48、 by the colour red) and/or letters and/or symbols. b) The temperature control device for mixing taps shall be identified either by means of a scale and/or symbols and/or by colours (Cold water blue and Hot water red). c) The direction of operation of the temperature control device of mixers shall be
49、 identified. d) For taps with separate control devices, the cold water shall be on the right and the hot water on the left. For water saving mixing tapware, appropriate information to installers and users shall be provided. The manufacturer shall explain letters, symbols, etc. in case they decide to use them. 6 Materials 6.1 Chemical and hygienic characteristics All materials coming into contact with water intended for human consumption shall present no health risk nor cause any change of the drinking water in terms of quality, appeara