1、BRITISH STANDARD BS EN 116303:1996 Harmonized system of quality assessment for electronic components Blankdetail specification Electromechanical all-or-nothing heavy load relays of assessed quality (hermetically sealed, 5A to 25A) The European Standard EN 116303:1993 has the status of a British Stan
2、dardBSEN116303:1996 BSI 10-1999 ISBN 0 580 25483 6 Committees responsible for this British Standard The preparation of this British Standard was entrusted to Technical Committee EPL/94, General purpose relays and reed contact units, upon which the following bodies were represented. FEI (Federation o
3、f the Electronics Industry) Ministry of Defence National Supervising Inspectorate BSI PC Amendments issued since publication Amd. No. Date CommentsBSEN116303:1996 BSI 10-1999 i Contents Page Committees responsible Inside front cover National foreword ii Foreword 2 Text of EN116303 5BSEN116303:1996 i
4、i BSI 10-1999 National foreword This British Standard has been prepared by Technical Committee EPL/94 and is the English language version of EN116303:1993 Blank detail specification:Electromechanical all-or-nothing heavy load relays of assessed quality (hermetically sealed, 5A to 25A), published by
5、the Electronic Components Committee (CECC) of the European Committee for Electrotechnical Standardization (CENELEC). This standard lists the ratings, characteristics and inspection requirements which shall be included as mandatory requirements in any detail specification for this type of relay. Deta
6、il specifications shall conform to the requirements of this blank detail specification and to BSCECC00111 Rule of Procedure11. Specifications Part4:1991 Regulations for CECC detail specifications. The British Standard which implements the CECC Rules of Procedure is BS9000 General requirements for a
7、system for electronic components of assessed quality Part 2:1991 Specification for the national implementation of the CECC system. Cross-references International Standard Corresponding British Standard CECC 00114-2:1994 BS CECC 00114 Rule of procedure 14 Quality assessment procedures Part 2:1995 Qua
8、lification approval of electronic components CECC 50000:1986 BS CECC 50000:1987 Harmonized system of quality assessment for electronic components Generic specification: Discrete semiconductor devices EN 116300:1993 BS EN 116300:1994 Harmonized system of quality assessment for electronic components.
9、Sectional specification: Electromechanical all-or-nothing heavy load relays of assessed quality (rated from 5A and above) BS 2011 Environmental testing IEC 68-2-14:1984 Part 2.1N:1985 Test N. Change of temperature IEC 68-2-2:1979 Part 2.1T:1981 Test T. Soldering IEC 68-2-21:1983 Part 2.1U:1984 Test
10、U. Robustness of terminations and integral mounting devices IEC 68-2-43:1976 Part 2.1Kd:1977 Test Kd. Hydrogen sulphide test for contacts and connections IEC 68-2-47:1982 BS EN 60068-2-47:1993 Environmental testing. Tests Mounting of components, equipment and other articles for dynamic tests includi
11、ng shock (Ea), bump (Eb), vibration (Fc and Fd) and steady-state acceleration (Ga) and guidanceBSEN116303:1996 BSI 10-1999 iii A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Complian
12、ce with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i to iv, theENtitle page, pages 2 to 28 and a back cover. This standard has been updated (see copyright date) and may have had am
13、endments incorporated. This will be indicated in the amendment table on the inside front cover.iv blankEUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 116303 August 1993 UDC Descriptors: Quality, electronic components, relays English version Blank detail specification: Electromechanical all-or-
14、nothing heavy load relays of assessed quality (hermetically sealed, 5 A to 25 A) Spcification particulire cadre: Relais lectromcaniques de tout-ou-rien soumis au rgime dassurance de la qualit, haute limite de charge (hermtique, 5 A 25 A) Vordruck fr Bauartspezifikation: Gtebesttigte elektromechanisc
15、he Schaltrelais von hoher Belastbarkeit (hermetisch dicht, 5 A bis 25 A) This European Standard was approved by the CENELEC Electronic Components Committee (CECC) on 10 August 1992. CENELEC members are bound to comply with CEN/CENELEC Internal Regulations which stipulate the conditions for giving th
16、is European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the General Secretariat of the CECC or to any CENELEC member. This European Standard exists in three off
17、icial versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CECC General Secretariat has the same status as the official versions. CENELEC members are the national electrotechnica
18、l committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, and United Kingdom. The membership of the CECC is identical, with the exception of the national electrotechnical committees of
19、Greece, Iceland and Luxembourg. CECC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B-1050 Brussels 1993 Copyright reserved to CENELEC members Ref. No. E
20、N 116303:1993 EEN116303:1993 BSI 10-1999 2 Foreword The CENELEC Electronic Components Committee (CECC) is composed of those member countries of the European Committee for Electrotechnical Standardization (CENELEC) who wish to take part in a harmonized System for electronic components of assessed qua
21、lity. The object of the System is to facilitate international trade by the harmonization of the specifications and quality assessment procedures for electronic components, and by the grant of an internationally recognized Mark, or Certificate, of Conformity. The components produced under the System
22、are thereby acceptable in all member countries without further testing. This specification was prepared by CECCWG16“Relays”. The text of the draft based on document CECC (Secretariat)2827 was submitted to the formal vote; together with the voting report, circulated as document CECC(Secretariat)3144,
23、 it was approved by CECC as EN116303 on 10August1992. The following dates were fixed: Contents Page Foreword 2 1 Related documents 5 2 Characteristic values of the relay 5 3 Qualification approval procedures 8 4 Quality conformance inspection 8 5 Marking, package and documentation 8 6 Annexes 9 7 Te
24、sts 9 8 Ordering information 10 Annex A Mounting variants, their dimensions and corresponding code 26 Annex B Termination variants, their dimensions and corresponding code 27 Annex C Wiring diagrams 28 Table 1 Dielectric test voltages 5 Table 2 Coil data 6 Table 3 Nominal load life and switching fre
25、quency 6 Table 3.1 Intermediate load, load distribution 7 Table 4 Time current characteristic 7 Table 5 Terminations 7 Table 5.1 Environmental stresses 8 Table 6 Lot-by-lot and periodic tests 10 Table 7 Tests for qualification approval 23 latest date of announcement of the ENat national level (doa)
26、1993-05-01 latest date of publication of an identical national standard (dop) 1993-11-01 latest date of declaration of national standards obsolescence 1993-11-01 latest date of withdrawal of conflicting national standards (dow) 2003-05-01EN116303:1993 BSI 10-1999 3 (1) CECC 16303-xxx Issue: Pages 1
27、to 25 (2) Electronic components of assessed quality in accordance with EN 116000-1:1992 (CECC 16000/I Issue 2) and EN 116300:1993 (3) (4) Detail specification for electromechanical all-or-nothing heavy load relays Type: (5) Construction: Hermetically sealed (RT V) Application category of contacts: C
28、A 4 (5 A to 25 A) (6) (7) Application (8) Outline Dimensions in mm Tolerances 0,25 mm, if not otherwise specified Relays according to this standard are capable of the following loads: (see section2.4). The relays are circuit breaker compatible. The relays may be delivered with or without screening (
29、assessment level Y or E). Coil data: (9) Contact data: (10) Operate ambient temperature range: . to + . C Storage temperature range: . to + . C Climatic category: T B /T A /21 Information about manufacturers who have components qualified to this detail specification is available in the current CECC
30、00200.EN116303:1993 4 BSI 10-1999 Key for page 3: The first page of the DS should have the layout recommended on page 3. The numbers between brackets on page 3 correspond to the following indications which should be given: Identification of the detail specification (1) The name of the National Stand
31、ardisation Organisation under whose authority the detail specification is published and, if applicable, the organisation from whom the detail specification is available. (2) The CECC-symbol and the number allotted to the completed detail specification by the CECC General Secretariat. (3) The number
32、and year of availability of the EN generic specification and/or sectional specification, also national reference, if different. (4) If different from the CECC number, the national number of the detail specification, date of issue and any further informations required by the national system, together
33、 with any amendment numbers. Identification of the relay (5) Type: sizes (e.g. half cubic inch), number and types of contacts, max. contact current. (6) Construction: e.g. hermetically sealed, type of termination, type of mounting, type of sealing, coil data, coil protection, life, other typical dat
34、a. (7) Basic outline drawing and wiring diagram; the detailed variants for terminals and mounting shall be given in annexes, if necessary. (8) Application of the relay: Stated application, mechanical, electrical and environmental conditions; Assessment level with or without screening. (9) Available
35、nominal coil voltages and, if applicable, nominal power. (10) Contact arrangement, contact current and voltage. (11) Temperature range and climatic category.EN116303:1993 BSI 10-1999 5 1 Related documents (Any other documents referred to in the DS shall be listed.) 2 Characteristic values of the rel
36、ay 2.1 General data Contact load: (current, voltage and frequency) Category of contacts: according to EN116000-1:1992 (CECC 16000/I, 1990), section 3.8 Mass (Weight): max. g Finish of the relay housing: Finish of the terminals: Insulation resistance: min. 100M Ohm at 500V d.c. Voltage proof: accordi
37、ng to Table 1 Table 1 Dielectric test voltages CECC 00114/II (1991) Quality Assessment Procedures; Part II: Qualification Approval of Electronic Components EN 116000-1:1992 (CECC 16000/I 2nd Issue 1990) Generic specification: Electromechanical all-or-nothing relays; Part 1: General EN 116300:1993 Se
38、ctional specification: Electromechanical all-or-nothing heavy load relays of assessed quality IEC 68-2-20 (1987) Basic Environmental Testing Procedures; Part 2: Tests; Test T: Soldering IEC 68-2-21 (1985) Basic Environmental Testing Procedures; Part 2: Tests; Test U: Robustness of terminations and i
39、ntegral mounting devices IEC 68-2-47 (1982) Basic Environmental Testing Procedures; Part 2: Tests; Mounting of components equipment and other articles for dynamic tests including shock (Ea), bump (Eb), vibration (Fc and Fd) and steady-state acceleration (Ga) and guidance. Dielectric test voltages r.
40、m.s. at 50 to 60Hz V at sea level at 2 kPa (25 000 m height) Between open contacts Between adjacent contacts Contact to case Coil to contacts Coil to caseEN116303:1993 6 BSI 10-1999 2.2 Construction of CECC type designation (ordering informations): Relays according to this specification shall be ord
41、ered according to the following example: Further informations shall be added, if necessary. For data processing purposes the ordering informations shall be written without blanks. 2.3 Coil data Table 2 Coil data 2.4 Contact data 2.4.1 Contacts (number, configuration and applicable categories) 2.4.2
42、Nominal load life and switching frequency Table 3 Nominal load life and switching frequency Code letter of coil with/without coil tansient suppression device 1) Voltage Resistance at Operate voltage d.c. or a.c. Release voltage d.c. or a.c. Permissible coil suppression output voltage V Type d.c. or
43、a.c. Value V 23 2 C Ohm 10 % 2) V V rated max. max. at max. at min. at 23 2 C UCT 23 2 C UCT 23 2 C LCT 1) Screened semiconductors according to CECC 50000 Level Y or JAN-TX or equivalent screened semiconductors shall be used. The relay shall continue to operate even in case of failure of the suppres
44、sion circuit. The suppression device shall sustain a peak value of 600 V, duration 10 4s. Wiring diagram shall be added. 2) Coil suppression device included, if applicable. Abbreviations: UCTUpper category temperature LCTLower category temperature JAN-TXProduct assurance requirements according to MI
45、L-S-19500, clause 3.4.1 Nominal load Number of switching cycles Switching frequencies at nominal load at d.c. 28 V at 115/200 V 400 Hz (one- and three-phase) Resistive . . . . . Inductive . . . . . Motor . . . . . Lamp . . . . . Intermediate load: resistive . . . . . inductive . . . . . Overload . .
46、 50 .EN116303:1993 BSI 10-1999 7 2.4.3 Statical voltage drop per contact max. . mV for brand-new relays max. . mV after life test 2.4.4 Mechanical life . . switching cycles at 25% of nominal load (resistive load) 2.4.5 Intermediate load, load distribution Table 3.1 Intermediate load, load distributi
47、on 2.4.6 Timing (over the whole temperature range): 2.4.7 Time current characteristic Table 4 Time current characteristic 2.5 Terminations The types and finish of terminations in relation to the respective code number shall be specified. Table 5 gives an example. Table 5 Terminations 2.6 Mounting Th
48、e mounting variants and the respective code letters shall be specified. Details and drawings shall be given inAnnex A. Max. contact voltage: .V d.c. resp. . V . Hz Min. contact voltage: .V d.c. resp. . V . Hz Min. contact current: . mA Test specimen No. 1 2 3 Changer No. 1 A resistive A resistive A
49、resistive 2 A resistive A resistive A resistive Coil for d.c. voltage a.c. voltage Operating time . ms max. . ms max. Release time (without suppression device) . ms max. . ms max. Release time (with suppression device) . ms max. . ms max. Bounce time . ms max. . ms max. Load A Load duration (resistive load) max. Code number Solder pins, tinned 1 Solder hooks, tinned 2 Plug-in type pins, gold plated 3 Dimensions of terminations according to Annex BEN116303:1993 8