1、BRITISH STANDARDBS EN 14784-2:2005Non-destructive testing Industrial computed radiography with storage phosphor imaging plates Part 2: General principles for testing of metallic materials using X-rays and gamma raysThe European Standard EN 14784-2:2005 has the status of a British StandardICS 19.100g
2、49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 14784-2:2005This British Standard was published under the authority of the Standards Policy and
3、 Strategy Committee on 27 September 2005 BSI 27 September 2005ISBN 0 580 46655 8National forewordThis British Standard is the official English language version of EN 14784-2:2005. The UK participation in its preparation was entrusted to Technical Committee WEE/46, Non-destructive testing, which has
4、the responsibility to:A list of organizations represented on this committee can be obtained on request to its secretary.Cross-referencesThe British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitl
5、ed “International Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance wi
6、th a British Standard does not of itself confer immunity from legal obligations. aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related internation
7、al and European developments and promulgate them in the UK.Summary of pagesThis document comprises a front cover, an inside front cover, the EN title page, pages 2 to 16, an inside back cover and a back cover.The BSI copyright notice displayed in this document indicates when the document was last is
8、sued.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14784-2August 2005ICS 19.100English versionNon-destructive testing - Industrial computed radiography withstorage phosphor imaging plates - Part 2: General principles fortesting of metallic
9、 materials using X-rays and gamma raysEssais non destructifs - Radiographie industriellenumrise avec plaques-images au phosphore - Partie 2 :Principes gnraux de lessai radioscopique, laide derayons X et gamma, des matriaux mtalliquesZerstrungsfreie Prfung - Industrielle Computer-Radiographie mit Pho
10、sphor-Speicherfolien - Teil 2:Grundlagen fr die Prfung von metallischen Werkstoffenmit Rntgen- und GammastrahlenThis European Standard was approved by CEN on 1 July 2005.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanS
11、tandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French
12、, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic,
13、Denmark, Estonia, Finland, France,Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia,Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROP
14、ISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2005 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14784-2:2005: EEN 14784-2:2005 (E) 2 Contents Page Foreword3 1 Scope 4 2 Normative references 4 3 Te
15、rms and definitions .4 4 Personnel qualification .5 5 Classification of computed radiographic techniques5 6 General6 7 Recommended techniques for making computed radiographs .6 8 Test report 14 Bibliography 16 EN 14784-2:2005 (E) 3 Foreword This European Standard (EN 14784-2:2005) has been prepared
16、by Technical Committee CEN/TC 138 “Non-destructive testing”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2006, and conflicting national stan
17、dards shall be withdrawn at the latest by February 2006. EN 14784 comprises a series of European Standards for industrial computed radiography with storage phosphor imaging plates which is made up of the following: EN 14784-1 Non-destructive testing Industrial computed radiography with storage phosp
18、hor imaging plates Part 1: Classification of systems EN 14784-2 Non-destructive testing Industrial computed radiography with storage phosphor imaging plates Part 2: General principles for testing of metallic materials using X-rays and gamma rays According to the CEN/CENELEC Internal Regulations, the
19、 national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Polan
20、d, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 14784-2:2005 (E) 4 1 Scope This European Standard specifies fundamental techniques of computed radiography with the aim of enabling satisfactory and repeatable results to be obtained economically. The techniques are b
21、ased on the fundamental theory of the subject and tests measurements. This document specifies the general rules for industrial computed X- and gamma radiography for flaw detection purposes, using storage phosphor imaging plates (IP). It is based on the general principles for radiographic examination
22、 of metallic materials on the basis of films (EN 444 and ISO 5579). The basic set-up of radiation source, detector and the corresponding geometry shall be applied in agreement with EN 444 and ISO 5579 and the corresponding product standards as e.g. EN 1435 for welding and EN 12681 for foundry. It do
23、es not lay down acceptance criteria of the imperfections. 2 Normative references The following referenced documents are indispensable for the application of this European Standard. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced docu
24、ment (including any amendments) applies. EN 462-1, Non-destructive testing Image quality of radiographs Part 1: Image quality Indicators (wire type) Determination of image quality value. EN 462-2, Non-destructive testing Image quality of radiographs Part 2: Image quality indicators (step/hole type)
25、Determination of image quality value. EN 462-3, Non-destructive testing Image quality of radiographs Part 3: Image quality classes for ferrous metals. EN 462-4, Non-destructive testing Image quality of radiographs Part 4: Experimental evaluation of image quality values and image quality tables. EN 4
26、62-5, Non-destructive testing Image quality of radiographs Part 5: Image quality indicators (duplex wire type), determination of image unsharpness value. EN 14784-1:2005; Non-destructive testing Industrial computed radiography with storage phosphor imaging plates Part 1: Classification of systems. 3
27、 Terms and definitions For the purposes of this European Standard, the following terms and definitions apply. 3.1 storage phosphor imaging plate systems complete system of a storage phosphor imaging plate (IP) and a corresponding read out unit (scanner or reader), which converts the information of t
28、he IP into a digital image 3.2 nominal thickness t nominal thickness of the material in the region under examination. Manufacturing tolerances do not have to be taken into account 3.3 penetrated thickness w thickness of material in the direction of the radiation beam calculated on basis of the nomin
29、al thickness. For multiple wall techniques the penetrated thickness is calculated from the nominal thickness. EN 14784-2:2005 (E) 5 3.4 object-to-detector distance b distance between the radiation side of the test object and the detector surface measured along the central axis of the radiation beam
30、3.5 source size d size of the source of radiation 3.6 source-to-detector distance (SDD) distance between the source of radiation and the detector measured in the direction of the beam 3.7 source-to-object distance f distance between the source of radiation and the source side of the test object meas
31、ured along the central axis of the radiation beam 4 Personnel qualification The examination should be carried out by qualified and capable personnel. In order to prove this qualification, it is recommended to certify the personnel in accordance with EN 473 or ISO 9712. 5 Classification of computed r
32、adiographic techniques Computed radiographic techniques are subdivided into two classes: Class A: basic technique; Class B: improved technique. Class B technique will be used when class A may be insufficiently sensitive. Better techniques, compared with class B, are possible and may be agreed betwee
33、n the contracting parties by specification of all appropriate test parameters. The choice of radiographic technique shall be agreed between the parties concerned. Due to image parameters such as SNR, un-sharpness and sensitivity to scattered radiation and hardening differences exist between film rad
34、iographs and computed radiographs. Nevertheless, the perception of flaws using film radiography or computed radiography is comparable by using class A and class B techniques, respectively. The perceptibility shall be proven by the use of IQIs according to EN 462-1, EN 462-2 and EN 462-5. If it is no
35、t possible for technical reasons to meet one of the conditions specified for the class B, such as the type of radiation source or the source-to-object distance f, it may be agreed between the contracting parties that the condition selected may be that specified for class A. The loss of sensitivity s
36、hall be compensated for, by doubling the required minimum exposure time with the goal to increase the minimum SNR by a factor of 1.4 (additional to the SNR required from the plate-scanner classes given by Tables 2 to 3). Because of the resulting improved sensitivity compared to class A, the test sec
37、tions may be regarded as examined within class B. NOTE This applies only to those IP-scanner systems whose SNR is not limited by the in-homogeneity of the phosphor layer or the scanner dynamic at the required minimum exposure time (see clause 7.9). EN 14784-2:2005 (E) 6 6 General 6.1 Protection agai
38、nst ionising radiation WARNING Exposure of any part of the human body to X-rays or gamma-rays can be highly injurious to health. Wherever X-ray equipment or radioactive sources are in use, appropriate legal requirements must be applied. Local or national or international safety precautions when usin
39、g ionizing radiation shall be strictly applied. 6.2 Surface preparation and stage of manufacture In general, surface preparation is not necessary, but where surface imperfections or coatings might cause difficulty in detecting defects, the surface shall be ground smooth or the coatings shall be remo
40、ved. Unless otherwise specified computed radiography shall be carried out after the final stage of manufacture, e.g. after grinding or heat treatment. 6.3 Identification of radiographs Symbols shall be affixed to each section of the object being radiographed. The images of these symbols shall appear
41、 in the radiograph outside the region of interest where possible and shall ensure unequivocal identification of the section. 6.4 Marking Permanent markings on the object to be examined shall be made in order to locate accurately the position of each radiograph. Where the natures of the material and/
42、or its service conditions do not permit permanent marking, the location may be recorded by means of accurate sketches or photographs. 6.5 Overlap of phosphor imaging plates When radiographing an area with two or more separate phosphor imaging plates (IP), the IPs shall overlap sufficiently to ensure
43、 that the complete region of interest is radiographed. This shall be verified by a high-density marker on the surface of the object that will appear on each image. 6.6 Image quality indicators The quality of image shall be verified by use of IQIs, in accordance with the specific application of the f
44、ollowing European Standards - EN 462-1 for the contrast resolution and EN 462-5 for measurement of un-sharpness. Therefore, two IQIs are always required on each image. The minimum IQI-values in dependence on wall thickness and geometry are defined by EN 462-3. This document may be applied to non-fer
45、rous metals if appropriate IQIs are used. In specific application cases minimum IQI-values may be specified in accordance with EN 462-4. IQIs of the step-hole type (e.g. EN 462 2) should not be applied because the wire IQIs are more suitable to encourage the operator to compensate for limited sharpn
46、ess with increased contrast. This compensation can be achieved either by reduction of the source voltage or by longer exposure time to increase the SNR of the computed radiograph. 7 Recommended techniques for making computed radiographs 7.1 Test arrangements Test arrangements shall be determined fro
47、m the specific application standards for film radiography as e.g. EN 1435 and EN 12681. EN 14784-2:2005 (E) 7 7.2 Choice of X-ray tube voltage and radiation source 7.2.1 X-ray equipment To maintain good flaw detection sensitivity, the X-ray tube voltage should be as low as possible. The maximum valu
48、es of tube voltage versus thickness are given in Figure 1. Key X penetrated thickness w, in millimetres Y X-ray voltage, in kilovolts Figure 1 Maximum X-ray voltage for X-ray devices up to 500 kV as function of penetrated wall thickness 7.2.2 Other radiation sources The permitted penetrated thicknes
49、s ranges for gamma ray sources and X-ray equipment above 1 MeV are given in Table 1. By agreement of the contracting parties the value for Ir 192 may be reduced furthermore to 10 mm and for Se 75 to 5 mm penetrated wall thickness. On thin specimens, gamma rays from Ir-192 and Co-60 will not produce computed radiographs having as good a defect detection sensitivity as X-rays used with appropriate technique parameters. However, because of the advantages of gamma ray sources in handling and accessibility, Table 1 gives a r
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1