1、BRITISH STANDARDBS EN 14989-1:2007Chimneys Requirements and test methods for metal chimneys and material independent air supply ducts for roomsealed heating applications Part 1: Vertical air/flue terminals for C6-type appliancesThe European Standard EN 14989-1:2007 has the status of a British Standa
2、rdICS 91.060.40g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58BS EN 14989-1:2007This British Standard was published under the authority of the Stan
3、dards Policy and Strategy Committee on 28 September 2007 BSI 2007ISBN 978 0 580 54462 0National forewordThis British Standard is the UK implementation of EN 14989-1:2007. The UK participation in its preparation was entrusted by Technical Committee B/506, Chimneys, to Subcommittee B/506/5, Chimneys a
4、nd their components having inner linings of metal.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance wi
5、th a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 14989-1February 2007ICS 91.060.40English VersionChimneys - Requirements and test methods for metal chimneysand material indep
6、endent air supply ducts for roomsealedheating applications - Part 1: Vertical air/flue terminals for C6-type appliancesConduits de fume - Exigences et mthodes dessais pourconduits de fumes mtalliques et conduits dalimentationen air pour tous matriaux pour des appareils dechauffages tanches - Partie
7、1 : Terminaux verticauxair/fume pour appareils de type C6Abgasanlagen - Anforderungen und Prfverfahren frMetall-Abgasanlagen und materialunabhngigeLuftleitungen fr raumluftunabhngige Anlagen - Teil 1:Senkrecht angeordnete luft/Abgas-Aufstze frAbgasanlagen mit Gasgerten des Typs C6This European Stand
8、ard was approved by CEN on 7 January 2007.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning suc
9、h nationalstandards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language made by translationunder the responsibility of a CEN member into its own language a
10、nd notified to the CEN Management Centre has the same status as theofficial versions.CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland,France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg
11、, Malta, Netherlands, Norway, Poland, Portugal,Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManagement Centre: rue de Stassart, 36 B-1050 Brussels 2007 CEN All rights of ex
12、ploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 14989-1:2007: EEN 14989-1:2007 (E) 2 Contents Page Foreword4 Introduction .5 1 Scope 6 2 Normative references 6 3 Terms and definitions .6 4 Symbols 8 5 Manufacturers declaration for type test .10 6 Dimens
13、ions and tolerances 11 7 Performance requirements .11 7.1 Mechanical resistance and stability.11 7.1.1 Vertical load on the air/flue terminal11 7.1.2 Wind load11 7.2 Hygiene, health and environment 11 7.2.1 Gas tightness of the flue.11 7.2.2 Gas tightness of the air supply duct11 7.3 Safety in use.1
14、1 7.3.1 Thermal performance 11 7.3.2 Thermal resistance 12 7.3.3 Rainwater ingress12 7.3.4 Aerodynamic properties of the terminal .13 7.3.5 Resistance to ice formation15 7.3.6 Resistance to penetration by foreign objects.15 7.3.7 Materials .15 8 Product information.16 8.1 Manufacturers instructions
15、.16 8.2 Minimum information to be included in the manufacturers instructions .16 8.3 Sampling points.17 9 Marking .17 9.1 Air/flue terminal17 9.2 Packaging .18 10 Designation 18 10.1 General18 10.2 Temperature classes and test temperature 19 10.3 Pressure class19 10.4 Condensate resistance class .20
16、 10.5 Corrosion resistance.20 10.5.1 Corrosion resistance.20 10.5.2 Flue duct material specification for terminals 20 10.6 Resistance to fire (internal to external): Soot fire resistance and distance to combustible material .21 10.7 Additional characteristics.21 10.7.1 Wind class 21 10.7.2 Ice/rain
17、class 21 10.7.3 Pilot flame class.22 11 Evaluation of conformity.22 11.1 General22 EN 14989-1:2007 (E) 3 11.2 Type testing .22 11.2.1 General .22 11.2.2 Further type testing.23 11.2.3 Sampling for type testing .23 11.3 Factory production control (FPC)23 11.3.1 General .23 11.3.2 Equipment 24 11.3.3
18、Raw materials and components 24 11.3.4 Product testing and evaluation24 11.3.5 Non conforming products 24 12 Test methods .25 12.1 Mechanical resistance and stability 25 12.1.1 Vertical load on the air/flue terminal .25 12.1.2 Wind load .25 12.1.3 Gas tightness of the flue.25 12.1.4 Gas tightness of
19、 the air supply duct .26 12.2 Safety in use 26 12.2.1 Test environment.26 12.2.2 Test assembly27 12.2.3 Hot gas generator28 12.2.4 Procedure.29 12.3 Rainwater ingress37 12.3.1 Test assembly37 12.3.2 Procedure.38 12.4 Aerodynamic behaviour of air/flue terminal .38 12.4.1 Test assembly38 12.4.2 Test p
20、rocedure.42 12.4.3 Results44 12.5 Icing test.44 12.5.1 Test assembly44 12.6 Resistance to penetration by foreign objects 45 12.6.1 Test assembly45 12.6.2 Procedure.45 12.6.3 Results45 12.7 Low temperature test 46 Annex A (informative) Typical dimensions.47 Annex B (informative) Sampling for factory
21、production control51 Annex C (normative) Choice of size for type test and sampling53 Annex D (normative) Factory production control 55 Annex E (normative) Method of measuring the hot gas temperature57 Annex ZA (informative) Clauses of this European Standard addressing the provisions of the EU Constr
22、uction Products Directive .58 Bibliography64 EN 14989-1:2007 (E) 4 Foreword This document (EN 14989-1:2007) has been prepared by Technical Committee CEN/TC 166 “Chimneys”, the secretariat of which is held by UNI. This European Standard shall be given the status of a national standard, either by publ
23、ication of an identical text or by endorsement, at the latest by August 2007, and conflicting national standards shall be withdrawn at the latest by November 2008. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association, and sup
24、ports essential requirements of EU Directive(s). For relationship with EU Directive(s), see informative Annex ZA, which is an integral part of this document. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this
25、 European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and Unite
26、d Kingdom. EN 14989-1:2007 (E) 5 Introduction This standard covers vertical air/flue terminals with metal flue ducts for chimneys for roomsealed heating applications meaning the combination of flue duct and air supply duct needed for the correct functioning of a C6roomsealed appliance. The current r
27、equirements and test methods apply to balanced flue type applications. Requirements and test methods for other roomsealed applications will follow in separate documents. A standard covering the design, installation and commissioning of room sealed heating applications is in the current CEN/TC 166 wo
28、rk program, which includes this Part 1: Vertical Terminals for C6-type appliances, and Part 2: Flue and air supply ducts for individual roomsealed appliances. EN 14989-1:2007 (E) 6 1 Scope This standard specifies the requirements and test methods for positive pressure air/flue terminals with metal f
29、lue ducts for C62- and C63-type gas appliances, which convey air for combustion, and the products of combustion from appliances to the outside atmosphere. It also specifies the requirements for marking, manufacturers instructions, product information and evaluation of conformity. NOTE The classifica
30、tion of gas appliances is according to CEN/TR 1749. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including
31、 any amendments) applies. EN 573-3, Aluminium and aluminium alloys - Chemical composition and form of wrought products - Part 3: Chemical composition EN 1443:2003, Chimneys - General requirements EN 1856-1:2003, Chimneys - Requirements for metal chimneys - Part 1: System chimney products EN 1856-2:2
32、004, Chimneys - Requirements for metal chimneys - Part 2: Metal liners and connecting flue pipes EN 1859:2000, Chimneys - Metal chimneys - Test methods EN 10088-1, Stainless steels - Part 1: List of stainless steels EN 14241-1, Chimneys - Elastomeric seals and elastomeric sealants - Material require
33、ments and test methods - Part 1: Seals in flue liners EN 14471, Chimneys - System chimneys with plastic flue liners - Requirements and test methods 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 1443:2003, EN 1859:2000, EN 1856-1:2003, EN 1856-2:2004
34、 and the following apply. 3.1 air/flue terminal terminal unit consisting of a flue duct, which may be provided with a cover, and an air supply duct for the connection of a roomsealed appliance 3.2 air supply duct independent duct in a building, or a structural part of an air/flue terminal, conveying
35、 combustion air to a roomsealed appliance EN 14989-1:2007 (E) 7 3.3 concentric air/flue configuration configuration in which the chimney flue is fully surrounded by the air supply duct 3.4 flow resistance difference between the static pressures in the flue connection and the air supply duct connecti
36、on under dynamic conditions 3.5 friction length imaginary dimension for the flow resistance of the air/flue terminal expressed in metres of duct length 3.6 nominal diameter of the flue of the terminal (Dn) whole number representing the diameter of the flue of the terminal, expressed in millimetres 3
37、.7 nominal flow rate amount of air which flows at the nominal velocity through a duct with nominal diameter 3.8 nominal velocity velocity in a duct which characterises the velocity used in the test NOTE The actual test velocity may differ from the nominal velocity, because the actual inside diameter
38、 differs from the nominal diameter. 3.9 push-in spigot part of a pipe or fitting which is pushed into the socket of another pipe or fitting, thus resulting in a connection 3.10 re-circulation percentage ratio between the amount of flue gases leaking through the flue opening into the air supply duct
39、opening of the terminal and the total amount of flue gases produced 3.11 room-sealed appliance appliance in which the combustion circuit (air supply, combustion chamber, heat exchanger and evacuation of the products of combustion) is sealed with respect to the room in which the appliance is installe
40、d 3.12 separate air/flue configuration configuration in which the air supply duct and the chimney flue are separate (non-concentric) 3.13 socket part of a pipe or fitting which is pushed over the push-in spigot of another pipe or fitting, thus resulting in a connection 3.14 terminal adapter part of
41、the terminal used to connect the terminal to the air supply duct and the flue. It may include the transition from parallel to concentric configuration 3.15 wind pressure angle angle from which the wind (generated in the wind tunnel) hits the air/flue terminal EN 14989-1:2007 (E) 8 3.16 wind effect p
42、ressure additional pressure difference between the inlet and the outlet of the terminal due to the wind 3.17 balanced flue chimney system system where the air entry to the combustion air supply duct is adjacent to the discharge of combustion products from the flue, the inlet and outlet being so posi
43、tioned that wind effects are substantially balanced 4 Symbols acoefficient of heat transfer between the supply air and the outer surface of the flue duct in KmW2aBcoefficient of heat transfer between the outside of the air supply duct and the ambient air in KmW2i coefficient of heat transfer between
44、 the air and the inner surface of the flue duct in KmW2iBcoefficient of heat transfer between the supply air and the inner surface of the air supply duct in KmW2Adynamic viscosity of air for Tm in 2msN Bdynamic viscosity of air for TmB in 2msN Athermal conductivity of air for Tm in KmWBthermal condu
45、ctivity of air for TmB in KmW1thermal resistance of the flue duct in WKm2B1thermal resistance of the air supply duct in WKm2 density of air at 20 C = 1,2 in 3mkga density of airin 3mkgedensity of air for Te in 3mkgmdensity of air for Tm in 3mkgmBdensity of air for TmB in 3mkg coefficient of friction
46、 of the flue - Bthe higher of the value of the coefficient of friction of the inside of the air supply duct and the outside of the flue duct - EN 14989-1:2007 (E) 9 smoothcoefficient of friction of the flue for hydraulically smooth flow - smoothBcoefficient of friction of the air supply for hydrauli
47、cally smooth flow - coefficient of flow resistance, friction factor- A declared coefficient of flow resistance of the air supply duct of the terminal- F declared coefficient of flow resistance of the flue duct of the terminal- ABcross-sectional area of the air supply passage in m cp specific heat ca
48、pacity of air for Tmin KkJgcpBspecific heat capacity of air for TmBin KkJgd1external diameter of the push-in spigot of the flue duct in mmd2internal diameter of the socket of the flue duct in mmD1external diameter of the push-in spigot of the air supply in mmD2internal diameter of the duct socket of
49、 the air supply duct in mmDhhydraulic diameter of the flue in mDhahydraulic diameter of the outside of the flue duct in m DhaBhydraulic diameter of the outside of the air supply duct in m DhBhydraulic diameter of the air supply passage in m DhiBhydraulic diameter of the inside of the air supply duct in m Dndeclared nominal diameter of the terminal in mm kbcoefficient of heat transmission between the flue and the air supply passage at temperature equilibrium in KmW2kBbcoefficient of heat transmission between the s