1、BRITISH STANDARDBS EN 15283-2:2008+A1:2009 Gypsum boards with fibrous reinforcement Definitions, requirements and test methods Part 2: Gypsum fibre boardsICS 91.100.10g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g5
2、3g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58National forewordThis British Standard is the UK implementation of EN 15283-2:2008+A1:2009. It supersedes BS EN 15283-2:2008, which is withdrawn.The start and finish of text introduced or altered by amendment is indicated in the text
3、 by tags. Tags indicating changes to CEN text carry the number of the CEN amendment. For example, text altered by CEN amendment A1 is indicated by !“.The UK participation in its preparation was entrusted by Technical Committee B/544, Plastering, rendering, dry lining, to Subcommittee B/544/2, Gypsum
4、 based boards and ancillaries.A list of organizations represented on this subcommittee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Stan
5、dard cannot confer immunity from legal obligations.BS EN 15283-2:2008+A1:2009This British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 April 2008 BSI 2010Amendments/corrigenda issued since publicationDate Comments 28 February 2010 Implementation of
6、CEN amendment A1:2009ISBN 978 0 580 63866 4EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15283-2:2008+A1 August 2009 ICS 01.040.91; 91.100.10 Supersedes EN 15283-2:2008English Version Gypsum boards with fibrous reinforcement - Definitions, requirements and test methods - Part 2: Gypsum fibre
7、boards Plaques de pltre armes de fibres - Dfinitions, spcifications et mthodes dessai - Partie 2: Plaques de pltre fibres Faserverstrkte Gipsplatten - Begriffe, Anforderungen und Prfverfahren - Teil 2: Gipsfaserplatten This European Standard was approved by CEN on 28 December 2007 and includes Amend
8、ment 1 approved by CEN on 20 July 2009. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such
9、 national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language
10、 and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxem
11、bourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2009 CEN All righ
12、ts of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15283-2:2008+A1:2009: EEN 15283-2:2008+A1:2009 (E) 2 Contents Page Foreword 4Introduction .71 Scope 82 Normative references 83 Terms and definitions .94 Requirements 114.1 Mechanical characterist
13、ics 114.2 Fire behaviour . 124.3 Acoustic properties 124.4 Water vapour permeability / water vapour resistance (expressed as water vapour resistance factor) question for the mandate 124.5 Thermal resistance (expressed as thermal conductivity) 124.6 Dangerous substances 134.7 Dimensions and tolerance
14、s . 134.8 Additional requirements for gypsum fibre boards with reduced surface water absorption types GF-W1 and GF-W2 134.9 Additional requirements for gypsum fibre boards with reduced water absorption rate type GF-H . 134.10 Additional requirements for gypsum fibre boards with enhanced density type
15、 GF-D 134.11 Additional requirements for gypsum fibre boards with enhanced surface hardness type GF-I 144.12 Impact resistance 145 Test methods . 145.1 Sampling 145.2 Determination of width . 145.3 Determination of length . 155.4 Determination of thickness 165.5 Determination of squareness 175.6 Det
16、ermination of flexural strength (bending strength) . 195.7 Determination of deflection under load 215.8 Determination of surface water absorption . 225.9 Determination of total water absorption 235.10 Determination of density 235.11 Determination of surface hardness of the board 245.12 Determination
17、 of shear strength (strength of board/substructure connection) 266 Evaluation of conformity 286.1 General . 286.2 Initial type testing . 286.3 Factory production control 287 Designation of gypsum fibre boards 298 Marking, labelling and packaging . 30Annex A (informative) Sampling procedure for testi
18、ng 31A.1 General . 31A.2 Sampling procedure . 31Annex B (normative) Mounting and fixing for testing according to EN 13823 (SBI) . 32BS EN 15283-2:2008+A1:2009EN 15283-2:2008+A1:2009 (E) 3 Annex ZA (informative) Clauses of this European Standard addressing the provisions of EU Construction Products D
19、irective . 34ZA.1 Scope and relevant characteristics . 34ZA.2 Procedure for attestation of conformity of gypsum fibre boards 35ZA.3 CE marking and labelling . 38Bibliography 41BS EN 15283-2:2008+A1:2009EN 15283-2:2008+A1:2009 (E) 4 Foreword This document (EN 15283-2:2008+A1:2009) has been prepared b
20、y Technical Committee CEN/TC 241 “Gypsum and gypsum based products”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2010, and conflicting natio
21、nal standards shall be withdrawn at the latest by February 2010. This document includes Amendment 1, approved by CEN on 2009-08-19. This document supersedes EN 15283-2:2008. The start and finish of text introduced or altered by amendment is indicated in the text by tags!“XAttention is drawn to the p
22、ossibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This standard includes two parts: Part 1: Gypsum boards with mat reinforcement Part 2: Gypsum fibre boards This d
23、ocument has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association and supports essential requirements of EU Directive 89/106. For relationship with EU Directive(s) see informative Annex ZA which is an integral part of this document. According t
24、o the CEN/CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lit
25、huania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 15283-2:2008+A1:2009EN 15283-2:2008+A1:2009 (E) 5 Diagram 1 Families of gypsum products BS EN 15283-2:2008+A1:2009EN 15283-2:2008+A1:2009 (E) 6 Diag
26、ram 2 Family of ancillary products BS EN 15283-2:2008+A1:2009EN 15283-2:2008+A1:2009 (E) 7 Introduction Gypsum fibre boards are composed of set gypsum plaster core reinforced with fibres which may be inorganic and/or organic, dispersed in the core to form flat rectangular boards. Admixtures and fill
27、ers may also be present. They are usually continuously produced on an industrial scale. The properties of gypsum fibre boards make them particularly suitable for use in situations where there are requirements for fire protection, sound, thermal insulation or shear strength. Gypsum fibre boards may b
28、e fixed by various methods e.g. nailing, screwing, stapling or sticking with gypsum based or other adhesives. They may also be inserted in a suspended ceiling system or laid in floor constructions. Gypsum fibre boards may be finished with direct surface decoration or gypsum plaster. They may be furt
29、her processed into a range of other products. BS EN 15283-2:2008+A1:2009EN 15283-2:2008+A1:2009 (E) 8 1 Scope This European Standard specifies the characteristics and performance of gypsum fibre boards intended to be used in building construction works including those intended for secondary manufact
30、uring operations. It includes boards designed to receive either direct surface decoration or gypsum plaster. Gypsum fibre boards are selected for use according to their type, size, thickness and edge profile. The boards may be used for example, to provide dry lining finishes to walls, to fixed and s
31、uspended ceilings, to partitions, or as cladding to structural columns and beams. Other uses may be for floors and sheathing applications. This European Standard covers the following product performance characteristics: reaction to fire, water vapour permeability, flexural strength, and thermal resi
32、stance. The following performance characteristics are linked to systems assembled with gypsum fibre boards: shear strength, fire resistance, impact resistance, direct airborne sound insulation, acoustic absorption. If required, tests have to be done according to the corresponding European test metho
33、ds on assembled systems simulating the end use conditions. This European Standard also covers additional technical characteristics that are of importance for the use and acceptance of the product and the reference tests for these characteristics. It provides for evaluation of conformity of the produ
34、ct to this EN. This European Standard does not cover gypsum fibre boards that have been subject to any secondary manufacturing operations (e.g. insulating composite panels, boards with thin lamination etc.). Products covered by EN 520 or EN 13815 are excluded. 2 Normative references The following re
35、ferenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. !EN 338“, Structural timber Strength classes EN 12524, Building m
36、aterial and products Hygrothermal properties Tabulated design values EN 12664, Thermal performance of building materials and products Determination of thermal resistance by means of guarded hot plate and heat flow meter methods Dry and moist products of medium and low thermal resistance EN 13501-1,
37、Fire classification of construction products and building elements Part 1: Classification using data from reaction to fire tests EN 13501-2, Fire classification of construction products and building elements Part 2: Classification using data from fire resistance tests, excluding ventilation services
38、 EN 13823, Reaction to fire tests for building products Building products excluding floorings exposed to the thermal attack by a single burning item EN 13963, Jointing materials for gypsum plasterboards Definitions, requirements and test methods EN 14195, Metal framing components for gypsum plasterb
39、oard systems Definitions, requirements and test methods EN 20535, Paper and board Determination of water absorptiveness Cobb method (ISO 535:1991) BS EN 15283-2:2008+A1:2009EN 15283-2:2008+A1:2009 (E) 9 EN ISO 140-3, Acoustics Measurement of sound insulation in buildings and of building elements Par
40、t 3: Laboratory measurements of airborne sound insulation of building elements (ISO 140-3:1995) EN ISO 354, Acoustics Measurement of sound absorption in a reverberation room (ISO 354:1985) EN ISO 717-1, Acoustics Rating of sound insulation in buildings and of building elements Part 1: Airborne sound
41、 insulation (ISO 717-1:1996) EN ISO 9001, Quality management systems Requirements (ISO 9001:2000) EN ISO 12572, Hygrothermal performance of building materials and products Determination of water vapour transmission properties (ISO 12572:2001) ISO 7892, Vertical building elements Impact resistance te
42、sts Impact bodies and general test procedures 3 Terms and definitions For the purposes of this document, the following terms and definitions apply. 3.1 gypsum fibre boards gypsum fibre boards are composed of set gypsum plaster reinforced with dispersed fibres, which may be inorganic and/or organic,
43、to form flat rectangular boards. They may contain additives and/or fillers to impart additional properties. The surfaces may vary according to the use. The edges and the ends may be profiled to suit the application. Gypsum fibre boards are usually continuously produced on an industrial scale. For th
44、e purposes of identification these boards receive the designation GF 3.2 Additional features of gypsum fibre boards 3.2.1 gypsum fibre boards with reduced water absorption rate gypsum fibre boards may have additives to reduce the water absorption rate which make them suitable for special application
45、s in which reduced water absorption properties are required to improve the performance of the board. For the purposes of identification these boards receive the additional designation GF-H 3.2.2 gypsum fibre boards with reduced surface water absorption gypsum fibre boards may have additives to reduc
46、e the surface water absorption which make them suitable for special applications in which reduced water absorption properties are required to improve the performance of the board. For the purposes of identification, these boards receive the additional designation GF-W1, GF-W2 with different surface
47、water absorption performance 3.2.3 gypsum fibre boards with enhanced density boards may have enhanced density for special applications. For the purposes of identification these boards receive the additional designation GF-D, in accordance with their density 3.2.4 gypsum fibre boards with enhanced su
48、rface hardness boards may have enhanced surface hardness for special applications. For the purposes of identification these boards receive the additional designation GF-I BS EN 15283-2:2008+A1:2009EN 15283-2:2008+A1:2009 (E) 10 3.2.5 gypsum fibre boards with enhanced strength boards for special appl
49、ications where increased strength are required have increased bending strengths. For the purposes of identification these boards receive the additional designation GF-R1, GF-R2 with different strength performance 3.3 General terms 3.3.1 edge longitudinal side of the board 3.3.2 end side transverse to the edges 3.3.3 face surface intended to be exposed in use 3.3.4 back surface opposite to the face 3.3.5 width shortes