1、BS EN 15905:2010ICS 65.080NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDFertilizers Determination of3-methylpyrazole(MP) using high-performance liquidchromatography(HPLC)This British Standardwas published under theauthority of the StandardsPolicy and StrategyC
2、ommittee on 30 June2010 BSI 2010ISBN 978 0 580 65726 9Amendments/corrigenda issued since publicationDate CommentsBS EN 15905:2010National forewordThis British Standard is the UK implementation of EN 15905:2010.The UK participation in its preparation was entrusted to TechnicalCommittee CII/37, Fertil
3、isers and related chemicals.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract. Users are responsible for its correct application.Compliance with a British Standard ca
4、nnot confer immunityfrom legal obligations.BS EN 15905:2010EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15905 June 2010 ICS 65.080 English Version Fertilizers - Determination of 3-methylpyrazole (MP) using high-performance liquid chromatography (HPLC) Engrais - Dosage du 3-mthylpyrazole (MP)
5、 par chromatographie liquide haute performance (HPLC) Dngemittel - Bestimmung von 3-Methylpyrazol (MP) mit Hochleistungs-Flssigchromatographie (HPLC) This European Standard was approved by CEN on 29 April 2010. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate
6、 the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member. This European Standard exis
7、ts in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions. CEN members are the national standards b
8、odies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and United
9、Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2010 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 15905:2010: EBS
10、 EN 15905:2010EN 15905:2010 (E) 2 Contents Page Foreword 31 Scope 42 Normative references 43 Terms and definitions .44 Principle 45 Reagents .46 Apparatus .47 Sampling and sample preparation .58 Procedure .58.1 Preparation of the test solution 58.2 Preparation of the calibration solutions 58.3 HPLC
11、conditions 58.4 HPLC determination 69 Calculation and expression of the results 69.1 Calculation 69.2 Expression of results 610 Precision .710.1 Inter-laboratory test .710.2 Repeatability .710.3 Reproducibility .711 Test report 7Annex A (informative) Results of the inter-laboratory test .8Bibliograp
12、hy 9BS EN 15905:2010EN 15905:2010 (E) 3 Foreword This document (EN 15905:2010) has been prepared by Technical Committee CEN/TC 260 “Fertilizers and liming materials”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publicati
13、on of an identical text or by endorsement, at the latest by December 2010, and conflicting national standards shall be withdrawn at the latest by December 2010. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC sh
14、all not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CEN by the European Commission and the European Free Trade Association. According to the CEN/CENELEC Internal Regulations, the national standards organizations of the f
15、ollowing countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, S
16、lovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 15905:2010EN 15905:2010 (E) 4 1 Scope This European Standard specifies a method for the determination of the 3-methylpyrazole (MP) content in fertilizers, in particular in urea and materials containing urea using high-perfor
17、mance liquid chromatography (HPLC). 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments)
18、 applies. EN 1482-2, Fertilizers and liming materials Sampling and sample preparation Part 2: Sample preparation EN 12944-1:1999, Fertilizers and liming materials and soil improvers Vocabulary Part 1: General terms EN 12944-2:1999, Fertilizers and liming materials and soil improvers Vocabulary Part
19、2: Terms relating to fertilizers1)(including corrigendum AC:2000) EN ISO 3696:1995, Water for analytical laboratory use Specification and test methods (ISO 3696:1987) 3 Terms and definitions For the purposes of this document, the terms and definitions given in EN 12944-1:1999 and EN 12944-2:1999 app
20、ly. 4 Principle The sample of fertilizer is dissolved in water or extracted with water. The 3-methlypyrazole is determined in the solution using reversed phase high-performance liquid chromatography with an UV detector. 5 Reagents Use only reagents of recognized analytical grade and distilled or dem
21、ineralized water (grade 3 according to EN ISO 3696:1995). 5.1 Acetonitrile, HPLC purity. 5.2 De-ionized water, conductivity less than 0,5 mS/m according to ISO 3696, grade 3. 5.3 3-methylpyrazole. 6 Apparatus 6.1 Analytical balance, measuring accuracy 0,1 mg or better. 1) See corrigendum EN 12944-2:
22、1999/AC:2000 which corrects EN 12944-2:1999. BS EN 15905:2010EN 15905:2010 (E) 5 6.2 Ultrasonic bath. 6.3 Filtration equipment, (manual or pressure filtration). 6.4 Membrane filter, pore size 0,45 m or smaller. NOTE For samples which are difficult to filter, to the purpose a pressure filtration can
23、be used. 6.5 Volumetric flasks,100 ml, 1 000 ml. 6.6 HPLC device, for isocratic working procedure. 6.7 Sample issuing system. 6.8 UV detector. 6.9 Evaluation unit, e.g. electronic integrator. 6.10 Reversed phase HPLC separator column, e.g. C18 10 m, 250 mm 4 mm. NOTE With suitable separation perform
24、ance, it is also possible to use a shorter separation column. Instead of a C18 column, a separation column with hydroxyl phase can be used. 7 Sampling and sample preparation Sampling is not part of the method specified in this document. A recommended sampling method is given in EN 1482-1. Sample pre
25、paration shall be carried out in accordance with EN 1482-2. 8 Procedure 8.1 Preparation of the test solution Weigh a test portion corresponding to approximately 8 mg of 3-methlypyrazole into a 1 000 ml volumetric flask. Add approximately 750 ml of water (5.2) and dissolve in the ultrasonic bath (6.2
26、). Make up to the mark with water (5.2) and filter a part of the sample solution through a membrane filter (6.3, 6.4) in order to remove any un-dissolved substances which may still be present. This solution is used for the determination. NOTE The amount of ammonium nitrate-urea solution weighed in i
27、s 10 g, precise to 10 mg. For solid fertilizers, for reasons of homogeneity, an amount weighed in should be used of 100 g, precise to 0,1 g. In this case, the dilution of the filtrate by 1+9 is necessary; this is to be taken into account during the calculation. 8.2 Preparation of the calibration sol
28、utions Weigh 1 g of 3-methylpyrazole (5.3) to the nearest of 0,1 mg into a 1 000 ml volumetric flask. Dissolve with water (5.2), make up to the mark with water (5.2) and mix well. Pipette 10 ml of this solution into a 100 ml volumetric flask, make up to the mark with water (5.2) and mix well. Pipett
29、e 5 ml, 10 ml, and 15 ml of this solution into three 100 ml volumetric flasks. Make up each flask to the mark with water (5.2) and mix well. Take the solutions to create the calibration curve. 8.3 HPLC conditions Separation column: filling for reversed phase HPLC BS EN 15905:2010EN 15905:2010 (E) 6
30、Column temperature: room temperature Elution agent: water/acetonitrile (5.1) mixture 80+20 (volume fraction) Flow rate: 0,8 ml/min to 1,2 ml/min Injection volume: 20 l Wavelength: 214 nm The elution agent shall be degassed, e.g. in the ultrasonic bath (6.2). 8.4 HPLC determination To determine the c
31、alibration curve, inject an amount of 20 l of each calibration solution (see 8.2) three times. The calibration curve can be used to for the content determination if the correlation coefficient 0,99. The correlation coefficient is calculated in accordance with the method of smallest squares. Inject t
32、he test solution two times in succession. 9 Calculation and expression of the results 9.1 Calculation Carry out the evaluation on the basis of the calibration curve over the peak heights or the peak areas. Calculate the mass fraction of 3-methylpyrazole, wMP, in percent according to the following eq
33、uation: maFbAw=100)(dpkMP(1) where Apkis the peak height or peak area; b is the ordinate section of calibration curve; a is the rise of the calibration curve; Fdis the dilution factor; m is the mass of the test portion, in milligrams. 9.2 Expression of results Calculate the arithmetic mean from both
34、 values obtained. Indicate the result to the nearest 0,001 %. BS EN 15905:2010EN 15905:2010 (E) 7 10 Precision 10.1 Inter-laboratory test An inter-laboratory test has been carried out in 2008 with 9 participating laboratories and 2 different samples of fertilizers. This test yielded the data given i
35、n Annex A. Repeatability and reproducibility were calculated according to ISO 5725-1 and ISO 5725-2. The values derived from this inter-laboratory test may not be applicable to concentration ranges and matrices other than those given in Annex A. 10.2 Repeatability The absolute difference between two
36、 independent single test results, obtained with the same method on identical test material in the same laboratory by the same operator using the same equipment within a short interval of time, will in not more than 5 % of the cases exceed the values of r given in Table 1. 10.3 Reproducibility The ab
37、solute difference between two single test results, obtained with the same method on identical test material in different laboratories by different operators using different equipment, will in not more than 5 % of the cases exceed the values of R given in Table 1. Table 1 Mean values, repeatability a
38、nd reproducibility limits Sample x r R Liquid sample 1 0,030 4 0,000 3 0,003 9 Liquid sample 2 0,034 5 0,000 9 0,003 9 11 Test report The test report shall contain at least the following information: a) all information necessary for the complete identification of the sample; b) the test method used
39、with reference to this document; c) the test results obtained; d) date of sampling and sampling procedure (if known); e) date when the analysis was finished; f) whether the requirement of the repeatability limit has been fulfilled; g) all operating details not specified in this document, or regarded
40、 as optional, together with details of any incidents occurred when performing the method, which may have influenced the test result(s). BS EN 15905:2010EN 15905:2010 (E) 8 Annex A (informative) Results of the inter-laboratory test The precision of the method has been determined in the year 2008 in a
41、n inter-laboratory trial with 9 laboratories participating and carried out on 2 different liquid samples of fertilizer. The statistical results are given in Table A.1. Table A.1 Statistical results of the inter-laboratory test Parameter Liquid sample 1 Liquid sample 2 Year of the test 2008 2008 Numb
42、er of participating laboratories 9 9 Number of laboratories after eliminating outliers 8 9 mean value, x , (%) (mass fraction) 0,030 4 0,034 5 Repeatability standard deviation sr, (%) (mass fraction) 0,000 1 0,000 3 RSDr(%) (mass fraction) 0,30 0,93 Repeatability limit r (2,83 sr) (%) (mass fraction
43、) 0,000 3 0,000 9 Reproducibility standard deviation, sR(%) (mass fraction) 0,001 4 0,001 4 RSDR(%) (mass fraction) 4,63 4,03 Reproducibility limit R (2,83 sR) (%) (mass fraction) 0,003 9 0,003 9 BS EN 15905:2010EN 15905:2010 (E) 9 Bibliography 1 EN 1482-1, Fertilizers and liming materials Sampling
44、and sample preparation Part 1: Sampling 2 ISO 5725-1, Accuracy (trueness and precision) of measurement methods and results Part 1: General principles and definitions 3 ISO 5725-2, Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repea
45、tability and reproducibility of a standard measurement method 4 Regulation (EC) No 2003/2003 of the European Parliament and of the Council of 13 October 2003 relating to fertilisers, Official Journal L 304, 21.11.2003, p. 1-194 BS EN15905:2010BSI GroupHeadquarters 389Chiswick High Road,London, W4 4A
46、L, UKTel +44 (0)20 8996 9001Fax +44 (0)20 8996 - British Standards InstitutionBSI is the independent national body responsible for preparing BritishStandards. It presents the UK view on standards in Europe and at theinternational level. It is incorporated by Royal Charter.RevisionsBritish Standards
47、 are updated by amendment or revision. Users of BritishStandards should make sure that they possess the latest amendments oreditions.It is the constant aim of BSI to improve the quality of our products and services.We would be grateful if anyone finding an inaccuracy or ambiguity while usingthis Bri
48、tish Standard would inform the Secretary of the technical committeeresponsible, the identity of which can be found on the inside front cover. Tel:+44 (0)20 8996 9000. Fax: +44 (0)20 8996 7400.BSI offers members an individual updating service called PLUS which ensuresthat subscribers automatically re
49、ceive the latest editions of standards.Buying standardsOrders for all BSI, international and foreign standards publications should beaddressed to Customer Services. Tel: +44 (0)20 8996 9001. Fax: +44 (0)20 89967001 Email: You may also buy directly using a debit/creditcard from the BSI Shop on the Website http:/ response to orders for international standards, it is BSI
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有