1、BSI Standards PublicationBS EN 16122:2012Domestic and non-domesticstorage furniture Testmethods for the determinationof strength, durability andstabilityIncorporating corrigendum February 2015BS EN 16122:2012National forewordThis British Standard is the UK implementation of EN 16122:2012, incorporat
2、ing corrigendum February 2015.The UK participation in its preparation was entrusted by Technical Committee FW/0, Furniture, to Subcommittee FW/0/2, DomesticA list of organizations represented on this subcommittee can be obtained on request to its secretary.This publication does not purport to includ
3、e all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2015. Published by BSI Standards Limited 2015ISBN 978 0 580 89776 4ICS 97.140Compliance with a British Standard cannot confer immunity fromlegal obligations.This British
4、 Standard was published under the authority of the Standards Policy and Strategy Committee on 30 September 2012.Amendments/corrigenda issued since publicationDate Text affected30 April 2015 Implementation of CEN corrigendum February 2015: Modification to A.3.2, Weight and string systemBRITISH STANDA
5、RDand Contract Furniture.BS EN 16122:2012EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16122 July 2012 ICS 97.140 English Version Domestic and non-domestic storage furniture - Test methods for the determination of strength, durability and stability Meubles de rangement usage domestique et col
6、lectif - Mthode dessai pour la dtermination de la rsistance, la durabilit et la stabilit Behltnismbel fr den Wohn- und Nicht-Wohnbereich - Prfverfahren zur Bestimmung der Festigkeit, Dauerhaltbarkeit und Standsicherheit This European Standard was approved by CEN on 9 June 2012. CEN members are bound
7、 to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN
8、-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre ha
9、s the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Lu
10、xembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2012 C
11、EN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16122:2012: EIncorporating corrigendum February 2015BS EN 16122:2012EN 16122:2012 (E) 2 Contents Page Foreword 41 Scope 52 Normative references 53 Terms and definitions .54 General tes
12、t conditions .74.1 Preliminary preparation 74.2 Application of forces .84.3 Tolerances 84.4 Prevention of movement during test .84.5 Loading .85 Test equipment and apparatus .86 Test procedures for non-movable parts . 106.1 Shelves 106.1.1 General . 106.1.2 Shelf retention test horizontal outward fo
13、rce . 106.1.3 Shelf retention test vertical downward force 106.1.4 Deflection of shelves 106.1.5 Strength of shelf supports . 116.2 Tops and bottoms . 126.2.1 Sustained load test for tops and bottoms 126.2.2 Static load test for tops and bottoms . 126.3 Clothes rails and supports 126.3.1 General . 1
14、26.3.2 Dislodgement of clothes rails 136.4 Strength of the structure 146.4.1 Test for structure and underframe 146.4.2 Drop test 166.4.3 Tests for units with castors or wheels . 177 Test procedures for movable parts . 177.1 Pivoted doors 177.1.1 General . 177.1.2 Strength of pivoted doors Vertical l
15、oad of pivoted doors . 177.1.3 Horizontal load of pivoted doors . 187.1.4 Slam shut of pivoted doors . 197.1.5 Durability of pivoted doors 207.2 Sliding doors and horizontal roll fronts . 217.2.1 General . 217.2.2 Slam shut/open of sliding doors and horizontal roll fronts . 217.2.3 Durability of sli
16、ding doors and horizontal roll fronts 227.3 Flaps . 227.3.1 Strength of bottom-hinged flaps . 227.3.2 Durability of flaps 237.3.3 Drop test for horizontally top-hinged doors/flaps . 237.4 Vertical roll fronts . 247.4.1 Slam shut/open of vertical roll fronts . 247.4.2 Durability of vertical roll fron
17、ts . 257.5 Extension elements 257.5.1 General . 25BS EN 16122:2012EN 16122:2012 (E) 3 7.5.2 Strength of extension elements . 257.5.3 Durability of extension elements . 267.5.4 Slam shut and open of extension elements . 287.5.5 Displacement of extension element bottoms . 297.5.6 Interlock test 297.6
18、Locking and latching mechanism tests 297.6.1 General . 297.6.2 Strength test for locking and latching mechanisms for extension elements . 297.6.3 Locking and latching mechanisms for doors, flaps and roll fronts . 307.6.4 Locking and latching mechanism durability test . 308 Trays . 308.1 General . 30
19、8.2 Sustained load test for trays 308.3 Drop test for trays . 309 Coat hooks Strength of coat hooks 3110 Units mounted to the building or other structure 3210.1 Units not supported by the floor 3210.1.1 General . 3210.1.2 Movable parts, shelf supports, tops and bottoms . 3210.1.3 Overload . 3210.1.4
20、 Dislodgement test . 3310.2 Units supported by the floor 3311 Stability tests . 3311.1 General . 3311.2 Doors, extension elements and flaps closed, all storage units unloaded 3311.2.1 Units that are, or can be, adjusted to a height of 1000 mm or less 3311.2.2 Units that are, or can be, adjusted to a
21、 height of more than 1000 mm 3411.3 Opening doors, extension elements and flaps, all storage units unloaded 3411.4 Doors, extension elements and flaps opened and unlocked 3411.4.1 All storage areas unloaded and all doors, extension elements and flaps open . 3411.4.2 All storage areas unloaded with o
22、verturning load . 3411.4.3 All storage areas loaded with overturning load . 3411.5 Doors, extension elements and flaps closed and locked, all storage units loaded . 3511.6 Dynamic stability test for units with castors 3512 Test report 35Annex A (normative) Apparatus for slam-shut/open test of extens
23、ion elements 37A.1 Principle 37A.2 Apparatus . 37A.3 Calibration 39A.3.1 Pneumatic apparatus 39A.3.2 Weight and string system . 39BS EN 16122:2012EN 16122:2012 (E) 4 Foreword This document (EN 16122:2012) has been prepared by Technical Committee CEN/TC 207 “Furniture”, the secretariat of which is he
24、ld by UNI. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by January 2013, and conflicting national standards shall be withdrawn at the latest by January 2013. Attention is drawn to the possibility
25、that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound
26、 to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal,
27、 Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 16122:2012EN 16122:2012 (E) 5 1 Scope This European Standard specifies tests methods for the determination of strength, durability and stability for all types of domestic and non-domestic storage furniture
28、 including domestic kitchen furniture. It does not apply to office, industrial, catering equipment and retail storage, nor to industrial storage lockers. Strength and durability tests do not assess the structure of the building (for example the strength of wall hanging cabinets); rather, they includ
29、e only the cabinets and the parts used for attachment. The wall and the wall attachments are not included. Requirements for safety, strength and durability can be found in other European Standards. Assessment of the effects of ageing, degradation and flammability is not included. Annex A (normative)
30、 contains details of test equipment for the slam open/shut testing of extension elements. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies.
31、For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 7619-2:2010, Rubber, vulcanized or thermoplastic Determination of indentation hardness Part 2: IRHD pocket meter method 3 Terms and definitions For the purposes of this document, the followi
32、ng terms and definitions apply. 3.1 catch device device which keeps or pulls a component in place but does not require a second action in order to release it EXAMPLE A magnetic catch or a self-closing-mechanism. 3.2 clear height unobstructed height above the top of the bottom surface, or the structu
33、re of the unit Note 1 to entry: For example, the top of the extension element below and the lower edge of the extension element above. See Figure 1. BS EN 16122:2012EN 16122:2012 (E) 6 Key 1 structure of the unit 2 clear height H Figure 1 Clear height 3.3 damper mechanism mechanism which gently brin
34、gs the component to a stop 3.4 extension element components that can be pulled out and pushed in EXAMPLE Drawers, suspended pocket files, keyboard trays. 3.5 flap horizontally hinged door, which opens upwards or downwards 3.6 free standing unit unit not intended to be attached to a load bearing stru
35、cture 3.7 interlock device which restrains the opening of more than one extension element at a time 3.8 latching mechanism mechanism which retains an extension element or a door in the closed position and which requires a second action to release it and may require a key or a combination in order to
36、 activate it 3.9 locking mechanism mechanism that limits access to the interior of a unit or a storage element and that requires a key or a combination in order to activate it or to make it possible to activate it 3.10 stay hardware component usually used to hold a flap or door in the open position
37、BS EN 16122:2012EN 16122:2012 (E) 7 3.11 top hanging unit unit intended to be entirely supported by the ceiling 3.12 wall-, panel- and screen-hanging unit unit intended to be supported by a wall, panel or screen 3.13 tray storage element that is designed, under normal use, to be removed from the sto
38、rage unit and used independently 3.14 levelling device adjustable device intended to keep the item of furniture perpendicular to the floor EXAMPLE Adjustable feet or similar. 4 General test conditions 4.1 Preliminary preparation The unit(s)/component(s) shall be tested as delivered. The unit(s)/comp
39、onent(s) shall be assembled and/or configured according to the instructions supplied. Unless otherwise stated, the most adverse configuration shall be used for each test. If mounting or assembly instructions are not supplied, the mounting or assembly method shall be recorded in the test report. Fitt
40、ings shall be tightened before testing and shall not be re-tightened unless specifically required in the manufacturers instructions. If the configuration needs to be changed in order to produce the worst-case conditions, this shall be recorded in the test report. Levelling devices shall be set as ne
41、ar as possible to 5 mm from the fully open position whilst ensuring the unit is perpendicular to the floor. A combination of tests may be necessary to cover the properties of multifunction components; e.g. a receding door shall be tested both as a sliding door and as a pivoted door. Unless otherwise
42、 specified by the manufacturer, the sample for test shall be stored in indoor ambient conditions for at least 24 hours immediately prior to testing. Except for the deflection of shelves (see below), the tests shall be carried out in indoor ambient conditions at a temperature between 15 C and 25 C. I
43、f during a test the temperature is outside of the range of 15 C to 25 C, the maximum and/or minimum temperature shall be recorded in the test report. The test for deflection of shelves (6.1.4), except metal, stone and glass shelves, shall be carried out at a relative humidity of 45 % to 55 %. If dur
44、ing a test the relative humidity is outside this range, the maximum and/or minimum shall be recorded in the test report. If a test cannot be carried out as specified in this Standard, e.g. because a loading pad cannot be used for the application of a force due to the design of a product, the test sh
45、all be carried out as closely as possible to that specified. Before beginning the testing, visually inspect the unit thoroughly. Record any defects so that they are not assumed to have been caused by the tests. Carry out measurements, if specified. During testing, the unit shall be placed on the flo
46、or and levelled, unless otherwise specified. All tests specified for a particular component shall be carried out on the same sample. BS EN 16122:2012EN 16122:2012 (E) 8 4.2 Application of forces The test forces in the static load tests shall be applied sufficiently slowly to ensure that negligible d
47、ynamic force is applied. Unless otherwise specified, each specified force shall be maintained for not less than 10 s and not more than 15 s. The test forces in durability tests shall be applied at a rate to ensure that excessive heating does not occur. Unless otherwise specified, each test force sha
48、ll be maintained for (2 1) s. The forces may be replaced by masses. The relationship 10 N = 1 kg shall be used. 4.3 Tolerances Unless otherwise stated, the following tolerances are applicable to the test equipment: Forces: 5 % of the nominal force; Velocities: 5 % of the nominal velocity; Masses: 1
49、% of the nominal mass; Dimensions: 1 mm of the nominal dimension; Angles: 2 of the nominal angle. The accuracy for the positioning of loading pads and impact plates shall be 5 mm. NOTE For the purposes of uncertainty measurement, test results are not considered to be adversely affected when the above tolerances are met. 4.4 Prevention of movement duri