1、BSI Standards PublicationBS EN 16703:2015Acoustics Test codefor drywall systems ofplasterboard with steel studs Airborne sound insulationBS EN 16703:2015 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 16703:2015. The UK participation in its preparation was entr
2、usted to TechnicalCommittee EH/1/6, Building acoustics.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The Bri
3、tish Standards Institution 2015. Published by BSI Standards Limited 2015ISBN 978 0 580 84961 9 ICS 91.060.10; 91.120.20 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Standards Policy and Strategy Commit
4、tee on 30 September 2015.Amendments/corrigenda issued since publicationDate T e x t a f f e c t e dBS EN 16703:2015EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16703 September 2015 ICS 91.060.10; 91.120.20 English Version Acoustics - Test code for drywall systems of plasterboard with steel s
5、tuds - Airborne sound insulation Acoustique - Code dessai pour systmes de cloisons sches en plaques de pltre avec montants en acier - Mesure de laffaiblissement arien Akustik - Prfvorschrift fr Trockenwandsysteme aus Metallstnderwnden mit Gipsplattenbeplankung - Messung der Luftschalldmmung This Eur
6、opean Standard was approved by CEN on 8 August 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references co
7、ncerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member
8、into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France
9、, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMI
10、TEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16703:2015 EBS EN 16703:2015EN 16703:2015 (E) 2 Contents European foreword 4 Introduction 5 1 Scop
11、e . 6 2 Normative references 6 3 Terms and definitions . 6 4 Test code for drywall systems of plasterboard with steel studs . 7 4.1 Application 7 4.2 Testing Guidelines 7 4.2.1 Test element . 7 4.2.2 Boundary and mounting conditions 7 4.2.3 Test report 8 4.3 Validation of the laboratory with two ref
12、erence test partitions . 8 4.3.1 Test elements . 8 4.3.2 Acceptance criteria 8 4.3.3 Remedial investigation . 10 4.4 Application of uncertainties . 11 Annex A (normative) Reference test partition location in aperture . 12 A.1 General . 12 A.2 Case A “Aperture without niche and one acoustic break” 12
13、 A.3 Case B “Aperture without niche and two acoustic breaks with Ratio 2:1”. 13 A.4 Case C “Aperture with niche and one acoustic break” . 13 Annex B (normative) Reference test partition Type 1 . 14 B.1 Description of Reference test partition Type 1 14 B.1.1 Single Framework, single board layer parti
14、tion . 14 B.2 Installation procedure of partition Type 1 15 B.2.1 Installation of framework with channels and studs 15 B.2.2 Installation of plasterboards 1st side . 16 B.2.3 Installation of insulation in cavity 16 B.2.4 Installation of plasterboards 2nd side 16 B.2.5 Jointing for both sides of the
15、partition 16 Annex C (normative) Reference test partition Type 2 18 C.1 Twin framework, double board layer partition 18 C.1.1 General . 18 C.1.2 Installation of framework with channels and studs 19 C.2 Installation of plasterboards 20 C.2.1 General . 20 BS EN 16703:2015EN 16703:2015 (E) 3 C.2.2 Plas
16、terboard inner layer on first side . 20 C.2.3 Plasterboard outer layer on first side . 20 C.3 Installation of insulation in cavity 21 C.4 Installation of plasterboards 2nd side - Plasterboard inner layer on second side 21 C.5 Plasterboard outer layer on second side . 21 C.6 Jointing for both sides o
17、f the partition 21 Annex D (informative) Interlaboratory Tests performed for the development of this Test Code standard 22 Annex E (informative) E Modulus - Control Method (static E Modulus with 3 bending points) 24 Annex F (informative) E Modulus - Expertise Method (dynamic E Modulus) 25 Bibliograp
18、hy . 27 BS EN 16703:2015EN 16703:2015 (E) 4 European foreword This document (EN 16703:2015) has been prepared by Technical Committee CEN/TC 126 “Acoustic properties of building elements and of buildings”, the secretariat of which is held by AFNOR. This European Standard shall be given the status of
19、a national standard, either by publication of an identical text or by endorsement, at the latest by March 2016, and conflicting national standards shall be withdrawn at the latest by March 2016. Attention is drawn to the possibility that some of the elements of this document may be the subject of pa
20、tent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This standard is a complement to the European Standard EN ISO 10140-1 and is not intended to replace it. The complement includes more stringent rules, narrower tolerances and new, additional
21、requirements. According to the CEN-CENELEC Internal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedoni
22、a, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 16703:2015EN 16703:2015 (E) 5 Introduction Product standard EN 520:
23、2004+A1:2009 “Gypsum plasterboards Definitions, requirements and test methods” specifies requirements and test methods and establishes how to declare characteristics and to affix the CE marking of products accordingly. In EN 520:2004+A1:2009, when a drywall partition with plasterboard and steel stud
24、s has an airborne sound insulation performance property, its sound reduction should be determined in accordance with EN ISO 140-3, now replaced by EN ISO 10140-2. The measured sound reductions are calculated into sound reduction index R,in third octave bands and into single number indexes, in accord
25、ance with EN ISO 717-1. Those single number ratings are used for the CE marking. Measurement of sound reduction according to EN ISO 10140-2 was known through earlier inter laboratory tests (ILT), to generate large spread in results from different laboratories. This was not suitable, either from a co
26、mpetition point of view or from an end-user perspective. Therefore, CEN/TC 126 “Acoustic properties of building elements and of buildings” decided to set up a working group, WG 9 “Test Code for drywall partition with plasterboard and steel studs”, with the scope to improve reproducibility by develop
27、ing a Test Code complementary to the EN ISO 10140-1. One part of this work was to organize ILT for sound reduction measurements, to assess the uncertainty of acoustic quantities (Annex D). This was used by the working group to prepare this test code for drywall systems, including guidelines of testi
28、ng installation and validation of laboratory, to decrease the level of uncertainty. BS EN 16703:2015EN 16703:2015 (E) 6 1 Scope This European Standard specifies information additional to EN ISO 10140-1 necessary to carry out efficiently and under standardized conditions the determination of the soun
29、d reduction index of drywall systems of plasterboard with steel studs according to EN ISO 10140-2 “Acoustics Laboratory measurement of sound insulation of -building elements Part 2: Measurement of airborne sound insulation”. Observe that all demands in EN ISO 10140-2 should still be fulfilled. In or
30、der to decrease the uncertainty, it specifies: additional guidelines for testing drywall systems of plasterboard with steel studs; and a method to validate laboratory by using two reference test partitions. The results obtained are used to convert frequency-dependent sound reduction index into singl
31、e number ratings, according to EN ISO 717-1. These performances can be used to compare different products, or, and to express a requirement, or, and as input into estimation methods, such as EN 12354-1. 2 Normative references The following documents, in whole or in part, are normatively referenced i
32、n this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 520:2004+A1:2009, Gypsum plasterboards Definitions, requirements and test meth
33、ods EN 13162, Thermal insulation products for buildings Factory made Mineral wool (MW) products Specification EN 13963, Jointing materials for gypsum boards Definitions, requirements and test methods EN 14195, Metal framing components for gypsum board systems Definitions, requirements and test metho
34、ds EN 14566, Mechanical fasteners for gypsum plasterboard systems Definitions, requirements and test methods EN ISO 10140 (all parts), Acoustics Laboratory measurement of sound insulation of building elements (ISO 10140, all parts) 3 Terms and definitions For the purposes of this document, the follo
35、wing term and definition apply. 3.1 drywall system of plasterboard with steel studs partition comprising a non load bearing metal frame partition enclosed by plasterboards BS EN 16703:2015EN 16703:2015 (E) 7 4 Test code for drywall systems of plasterboard with steel studs 4.1 Application 4.1.1 This
36、standard applies to non-load bearing metal frame partition comprising a metal frame enclosed by plasterboards. In general, the type, size, gauge and spacing of the studs, and the size, type and number of layers of plasterboard and eventual amount and type of cavity filling material in partition cons
37、tructions are determined by the performance requirements of the system. 4.1.2 The quantity to be determined is the sound reduction index R as a function of frequency. The definition of R is given in EN ISO 10140-2. 4.2 Testing Guidelines 4.2.1 Test element The partition size shall be between 9 m2 12
38、 m2. For all others information, refer to EN ISO 10140-1 and EN ISO 10140-2. 4.2.2 Boundary and mounting conditions 4.2.2.1 General rules The test element shall be mounted directly on the facilities frame; it shall not be a prefabricated full partition. The test element should be installed in a simi
39、lar manner to the actual construction with careful simulation of typical connections and sealing conditions at the perimeter and at all joints. 4.2.2.2 Perimeters mounting A gap of about 5 mm to 10 mm shall remain between the plasterboards and the reveal of the test opening. This gap shall be filled
40、 with appropriate material. Drying time has to respect product instruction according to 4.3.1 because the type of filler will have an influence on the performance of the partition. Cracks in the perimeter may occur, resulting in air leakage. To control risk a procedure shall be set in the laboratory
41、 to check this. This shall be at minimum a visual control but can also be any additional method. 4.2.2.3 Partition positions The sound reduction index of drywall system of plasterboard with steel studs is influenced by the mounting conditions in the test opening of the laboratory. Important installa
42、tion parameters include the niche depth and the position of the partition in relation to the acoustic break in the test aperture. The partition shall be installed into the test opening so that the niches on both sides of the partition have different depths with a ratio of 2:1. To improve the reprodu
43、cibility between laboratories and facilitate comparison of sound reduction indices for different drywall system of plasterboard with steel studs, the partition (even double wall) shall not be mounted across the acoustic break between sending and receiving room of the laboratory, but on the same side
44、 of the break as indicated in Annex A. Main mounting conditions are reported in Annex A; others may be used but shall be fully described in the test report. BS EN 16703:2015EN 16703:2015 (E) 8 NOTE Mounting the lightweight partition with one leaf on one side and the other leaf on the other side of t
45、he acoustic break can result in higher values for the sound reduction index. Other mounting conditions may be suitable for certain types of twin leaf walls, for example, walls for semidetached houses where the leaves are vibrationally uncoupled (for example on separate foundations). In such cases th
46、e wall leaves can be mounted on each side of the acoustic break. No absorption material should be located close (less than 1 m) to the perimeter of the partition. The acoustic break has to be covered with soft reflecting materials. 4.2.3 Test report The test report shall include the information list
47、ed in EN ISO 10140-2:2010, Clause 9 and the following additional information shall also be reported: a) detailed description of the perimeters treatments; b) detailed description of the putty used and its drying time; c) detailed description of the fasteners used (screws spacing, stud centre) includ
48、ing perimeter frame; d) detailed description of the partition position ; it is recommended to refer to Annex A. 4.3 Validation of the laboratory with two reference test partitions 4.3.1 Test elements To reduce expanded uncertainty in a reproducibility condition of drywall plasterboard partition with
49、 steel stud, it is required to conduct preliminary tests with two laboratory reference test partitions described in Annexes B and C. The materials used to conduct these reference test partition tests should be products in accordance with the properties reported in Tables B.1 and C.1. The properties of the products mentioned shall be measured using the methods within the relevant product standard except for the E-modulus properties. The position of the reference test partitions shall be in accordance with Annex A. The installation of the referen
copyright@ 2008-2019 麦多课文库(www.mydoc123.com)网站版权所有
备案/许可证编号:苏ICP备17064731号-1