1、BRITISH STANDARD Harmonized system of quality assessment for electronic components BS EN 181103 : 1998 Blank detail specification: Fibre optic branching devices - me: Non wavelength selective transmissive star for telecommunication application The European Standard EN 181103 : 1997 has the status of
2、 a British Standard ICs 33.180.20 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW STD-BSI BS EN LBLL03-ENGL 1998 m Lb24bb Ob72825 O20 BS EN 181103 : 1998 This British Standard, having been prepared under the direction of the Electrotechnicai Sector Board, was published under t
3、he authority of the Standards Board and comes into effect on 15 Aprii 1998 National foreword This British Standard is the English language version of EN 181103 : 1997 published by the European Electronic Components Committee (CECC) of the European Committee for Electrotechnid Standarization (CENELEC
4、). The UK participation in its preparation was enusted by Technical Committee EPM6, Fibre optics, to Subcommittee EPI536/2, Interconnecting devices and passive components, which has the responsibility to: - aid enquirers to understand the text; - present to the responsible internationaVEuropean comm
5、ittee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; - monitor related intedonal and European developments and promuigate them in the UK. A iist of organizations represented on this subcommittee can be obtained on request to its secretay. Cross-refe
6、rences The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled International Standards Correspondence Index, or by using the Find facility of the BSI Standards Electronic Catalogu
7、e. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct appiication. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document compris
8、es a front cover, an inside front cover, the EN title page, pages 2 to 30, an inside back cover and a back cover. Amendments issued since publication ID* I O BSI 1998 ISBN O 680 29390 4 STD-BSI BS EN L8LL03-ENGL 1998 W Lb24669 Ob9282b Tb7 W EUROPEAN STANDARD EN 181103 NORME EUROPENNE EUROPISCHE NORM
9、 December 1997 ICs 33.1 80.20 English version Blank Detail Specification: Fibre optic branching devices Type: Non wavelength selective transmissive star for telecommunication application Spcification particulire cadre: Dispositifs de couplage fibres optiques Type: Non slectif en longueur donde, tran
10、smission en toile Vordruck fr Bauartspetifikation: Lichtwellenleiter-Verzweiger Bauart: Nicht-wellenlngenselektiver Sternbertrager fr Anwendungen bei Nachrichtenbertragung This European Standard was approved by CENELEC on 1997-1 0-01. CENELEC members are bound to comply with the CENICENELEC Internal
11、 Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC membe
12、r. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC
13、members are the national electrotechnical committees of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. CENELEC European Committee for Electrotechnical Stan
14、dardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Centrai Secretariat: rue de Stassart 35, B - 1050 Brussels 1997 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 18f103:19
15、97 E STD-BSI BS EN 181103-ENGL 1998 m I1624669 Ob92827 9T3 m Page 2 EN 181103:1997 Foreword This European Standard was prepared by the Technical Committee CENELECRC CECC SC 86BXB, Fibre optic passive components. The text of the draft was submitted to the Unique Acceptance Procedure and was approved
16、by CENELEC as EN 181 103 on 1997-1 0-01. The following dates were fixed: - latest date by which the EN has to be implemented (dp) 1998-09-01 at national level by publication of an identical national standard or by endonement - latest date by which the national standards conflicting (dW) 1998-09-01 w
17、ith the EN have to be withdrawn STD=BSI BS EN 181103-ENGL 1998 = 1624669 0692828 83T Page 3 EN 181 103: 997 GUIDANCE FOR THE PREPARATION OF DETAIL SPECIFICATIONS 1 INTRODUCTION This specification is a BDS for Fibre Optic Branching Devices of the “Non wavelength selective transmissive star“ type. Thi
18、s includes instructions for preparing a DS. 2 QUALIFICATION APPROVAL 2. I PROCEDURE The DS shall state the qualification approval procedure to be used in accordance with clause 3.3 of EN 181000. 2.2 TEST SCHEDULE AND PERFORMANCE REQUIREMENTS The test schedule for qualification by the fixed sample pr
19、ocedure shall be given in table 1 of the DS (see clauses 2.2,4.5 and 4.6 of EN 181 000). 3 QUALITY CONFORMANCE INSPECTION 3.7 LOT-BY-LOT INSPECTION The test schedule for lot-by-lot inspection (groups A and B) shall be given in table 2 of the DS (see clauses 2.2, 4.5 and 4.6 of EN 181000). 3.2 PERIOD
20、IC INSPECTION The test schedule for periodic inspection (groups C and D) shall be given in table 3 of the DS (see clauses 2.2,4.5 and 4.6 of EN 181000) 4 PREPARATION OF DETAIL SPECIFICATIONS (DS) Each BDS is published separately as a pro format document, with numbered spaces provided for entering th
21、e information necessary to create a DS. If the spaces provided are too small, then the information shall be provided on additional sheets forming part of the completed DS. Instructions for filling in the numbered spaces in a BDS are given below: (1) The name of the ONH under whose authonty the DS is
22、 published and, if applicable, the organization from whom the DS is available. (2) The CECC symbol and the number allotted to the DS by the CECC General Secretariat. (3) The number and issue number of the CEGC GS; also the national reference), if different. STD-BSI BS EN 181103-ENGL 1998 m 1b24bb9 O
23、b92829 776 m Page 4 EN 181103:1997 (4) If different from the CECC number, the national number of the DS, date of issue and any further information required by the national system, together with any amendment numbers. (5) A brief description of the component or range of components. (6) The level of q
24、uality assessment (A, B, C or X), sampling procedure (fixed quanti or lot-by-lot) and the climatic category. For (5) and (6) the text to be given in the DS shall be suitable for an entry in CECC O0 200 (Register of Approvals) and CECC O0 300 (Register of National Documents). (7) An outline drawing w
25、ith main dimensions which are of importance for interchangeability, and/or reference to the appropriate national or international documents for outlines. Alternatively, this drawing may be given in an annex to the DS, but (7) shall always contain an illustration of the general outer appearance of th
26、e component. If an existing drawing from an IEC publication, or similar source, is used in a CECC specification, then it can be either first or third angle projection, but the appropriate symbol shall be shown on the drawing: st angle projection 3rd angle projection The symbol in the BDS may be conv
27、erted to indicate either Ist or 3rd angle, by deleting the inappropriate part of the drawing. Alternative outline dimensions or tolerance limits of any variants shall be shown, and may be listed in the form of a table alongside the drawing. (8) A list of variants and their identifying features cover
28、ed by the DS. Enter the identification number. “AYY“ for each variant of each component (see clause 2.7.1 of EN 181000). Assign a column in the table for each variant feature. For example, cable type, housing, orientation of ports, means of mounting etc. Instruction: - max. values in dB for insertio
29、n losses between conduction ports; - min. values in dB for return losses; - min. values in dB for insertion losses between isolated ports. (9) Supplementary infomation Enter the supplementary information with respect to marking of the component, marking and contents of package, ordering information,
30、 related documents, certified ted records and structural similanty. (1 O) Fixed sample qualficafion approval test schedule STD.BSI BS EN 11103-ENGL 1778 lb24bb9 Ob92830 478 Page 5 EN 181103:1997 (1) Specification available from (3) ELECTRONIC COMPONENT OF ASSESSED QUALITY IN ACCORDANCE WITH GENERIC
31、SPECIFICATION EN 181000 ISSUE 1 BLANK DETAIL SPECIFICATION EN 181103 Table 1 shall give the required measurements and tests for qualification by fixed-sample procedure. If qualification by lot-by-lot and periodic procedure is specified, insert “NOT APPLICABLE in table 1. (2) Page 1 Of . EN 181103- (
32、4) Issue . . If measurements or tests are specified for which no basic procedure is available, or which do not appear in the GS EN 181000, each procedure shall be clearly diecribed in an individual annex to the DS. The format and the minimum mandatory test sequence shall be the same as specified in
33、the GS. ( 1 1 ) Lot-by-lot inspection test schedule When completed, table 2 shall give the required measurements and tests for qualification by lot-by-lot procedure. One or more assessment level(s) shall be given in table 2. When differing from the preferred levels of the GS (see clause 2.1.5 of EN
34、181000) the IL and AQL shall be entered and the assessment level(s) titled (X, Y.). If measurements or tests are specified for which no basic procedure is available, or which do not appear in the GS, EN 181000, each procedure shall be clearly described in an individual annex to the DS. The format an
35、d the minimum mandatory test sequence shali be the same as specified in the GS. (1 2) Periodic C and D testing procedure Table 3 shall give the required measurements and tests for groups C and D periodic tests. One or more assessment level(s) shall be given in table 3. When differing from the prefer
36、red levels of the GS (see clause 2.1.5 of EN 181000) the IL, AQL, p, n, c and t shall be entered and the assessment leve) titled (X,Y .). (1 3) Details, measurements, and performance requirements Table 4 shall list the details of each tests requirements. It shall be noted that the mandatory tests ha
37、ve been given as a minimum. Others tests shall be given in the same manner.To fill in the detail of the test the values shall be taken out from the relevant I - ETS document STD.BS1 BS EN L81L03-ENGL 1998 lb24bb9 Ob92831 324 9 Page 6 EN 181103:1997 Variant No (5) DETAIL SPECIFICATION for 1 Operating
38、 wavelength range(s) (w) FIBRE OPTIC BRANCHING DEVICE OF ASSESSED QUALITY type : Non wavelength selective transmissive Star for Telecommunication applications Style: Configuration : Fibre type) : Connector set : Type: Splitterkombiner - Non Wavelength Selective - Uni- or Bidirectional - Transmissive
39、 star - Transfer matrix and numbering - NxM of ports: see page 2 (6) Assessment Qualification Approval Climatic Level: Procedure: Category: Panel piercing and mounting details:. (7) Outline dimensions and mass (7) Dimensions (mm) Ref. IMin Max INotes Figure . Mass (9) (8) Variants: W: Additional dra
40、wing (it nessary) see page . (8) Transft3r matrix and numbering of ports: 1 N+l i N+2 N, N+M ! : 2- STD-BSI BS EN LBLLO3-ENGL 139398 Lb24bb39 Ob392832 260 Page 7 EN 181103:1997 r air a, * 821 Launch Port 1 2 +MLaN+M, Note: Values in d . N+M * %N+M *N+MN+M STD-BSI BS EN 181103-ENGL 1998 = 1624669 069
41、2833 IT7 Page 8 EN 181103:1997 (9) SUPPLEMENTARY INFORMATION Marking of the component (add component marking requirements in accordance with 2.7.2 of EN 181000, as applicable) : Marking and contents of package (add component package marking requirements in accordance with 2.7.3 of EN 181000, as appl
42、icable) : Ordering information (add ordering information, as applicable) : Related documents (add additional related documents if not included in EN 181000) : Certified records of released lots (indicate whether a certificate is required) : Structural similarity (add the boundary limits in accordanc
43、e with 3.2 of EN 181000) : * * m I, . STD-BSI BS EN LBlL03-ENGL 1998 Lb24bb9 Ob92839 033 = Page 9 EN 181 103: 1997 (1 O) TABLE 1 FIXED SAMPLE QUALIFICATION APPROVAL TEST SCHEDULE Test sequence (Note) EN 181000 Clause Group 2 Further groups if applicable Sample size Note: For details, measurements an
44、d performance requirements see table 4 STD-BSI BS EN 181103-ENGL 1998 1624669 Ob92835 T7T Page 10 EN 181 103: 1997 EN 181000 Clause (11) TABLE 2 (GROUPS A AND B) LOT-BY-LOT INSPECTION TEST SCHEDULE Assessment Level (Note 2) Test Sequence (Note 1) Group A Group B I Note i: Note 2: For details, measur
45、ements and performance requirements see table 4 See clause 2.1.5 of EN 181000. STDmBSI BS EN 181103-ENGL II978 1624669 0692836 906 = Page 11 EN 181103:1997 Test Sequence EN 181000 (Note 1) Clause Assessment Level (Note 2) Group C1 Group C2 Further groups if applicable Group DO Group Di Group 02 Furt
46、her groups if applicable Not 1 : Note 2: For details, measurements and performance requirements see table 4 See clause 2.1.5 of EN 181000. Sample size (13) TABLE 4 (continued) DETAILS, MEASUREMENTS AND PERFORMANCE REQUIREMENTS STD-BSI BS EN II8LII03-ENGL 1998 m II624669 Ob92837 842 m Page 12 EN 1811
47、03:1997 Visual inspection: In accordance with EN 181000 clause 4.5.1 Details: - Configuration - Housing and orientation of the ports - Marking - Preconditioning procedure - Recovery procedure - Deviations Requirements: The configuration, the connector type if any, the orientation of the ports shall
48、be specified in (5); workmanship shall be in accordance with clause 2.4.2 of EN 181000; marking shall be in accordance with the requirements in (9). Page 13 EN 81103:1997 (13) TABLE 4 (continued) DETAILS, MEASUREMENTS AND PERFORMANCE REQUIREMENTS Dimensions and mass: In accordance with EN 181000 cla
49、use 4.5.2 Details: - Sue dimensions (mm) - Mass (9) - Size measurement method (if required) - Mass measurement method - Preconditioning procedure - Recovery procedure - Deviations Requirements: All size dimensions and mass shall be in accordance with (7). Page 14 EN 181 103:1997 (13) TABLE 4 (continued) DETAILS, MEASUREMENTS AND PERFORMANCE REQUIREMENTS Attenuation between conducting and isolated ports: see EN 181000 clause 4.5.5 Details: - Test method -Wavelength (nm) - Spectral width of source (nm) - Launch mode conditions - Lengths (m