1、BRITISH STANDARD BS EN 50117-2-5:2004Coaxial cables Part 2-5: Sectional specification for cables used in cabled distribution networks Outdoor drop cables for systems operating at 5 MHz - 3 000 MHzICS 33.120.10nullnull nullnullnullnullnullnullnull nullnullnullnullnullnullnull nullnullnull nullnullnul
2、lnullnullnullnullnullnullnull nullnullnullnullnullnull nullnull nullnullnullnullnullnullnullnullnull nullnull nullnullnullnullnullnullnullnullnull nullnullnull+A2:2013National forewordThis British Standard is the UK implementation of EN 50117-2-5:2004+A2:2013. It supersedes BS EN 50117-2-5:2004+A1:2
3、008, which is withdrawn.The start and finish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to CENELEC text carry the number of the CENELEC amendment. For example, text altered by CENELEC amendment A1 is indicated by .The UK participation in its
4、preparation was entrusted to Technical Committee EPL/46, Cables, wires and waveguides, radio frequency connectors and accessories for communication and signalling.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to in
5、clude all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BS EN 50117-2-5:2004+A2:2013This British Standard waspublished under the authorityof the Standards Policy andStrategy C
6、ommitteeon 17 December 2004 The British Standards Institution 2013. Published by BSI Standards Limited 2013.Amendments/corrigenda issued since publicationDate Comments 30 April 2009 Implementation of CENELEC amendment A1:200830 September 2013 Implementation of CENELEC amendment A2:2013ISBN 978 0 580
7、 77911 4EUROPEAN STANDARD EN 50117-2-5:2004+A2NORME EUROPENNE EUROPISCHE NORM CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 20
8、04 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.Ref. No. EN 50117-2-5:2004 EICS 33.120.10 English version Coaxial cables Part 2-5: Sectional specification for cables used in cabled distribution networks Outdoor drop cables for systems opera
9、ting at 5 MHz - 3 000 MHzCbles coaxiauxPartie 2-5: Spcification intermdiairepour les cbles utiliss dans les rseauxde distribution cbls Cbles de raccordement usage extrieur pour des systmes fonctionnant 5 MHz - 3 000 MHzKoaxialkabelTeil 2-5: Rahmenspezifikation fr Kabelfr Kabelverteilanlagen Aussenka
10、bel im Bereich von 5 MHz - 3 000 MHzThis European Standard was approved by CENELEC on 2004-09-01. CENELEC members arebound to complywith the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-
11、to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any otherlanguage made by translation u
12、nder the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus, CzechRepublic, Denmark, Estonia, Finland, France, Germany,
13、 Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. August 2013Foreword This European Standard wasprepared by SC46XA, Coaxial cab les, of Technical Committee CENELEC
14、TC 46X, Communication cables.The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50117-2-5 on 2004-09-01. The following dates were fixed: latest date by which the EN has to be implementedat national level by publication of an identicalnational standard or by endo
15、rsement (dop) 2005-09-01 latest date by which the national standards conflictingwith the EN have to be withdrawn (dow)2007-09-01 _ Foreword to amendment A1 This amendment to the European Standard EN 50117-2-5:2004 was prepared by SC 46XA, Coaxialcables, of Technical Committee CENELEC TC 46X, Communi
16、cation cables. The text of the draft was submitted to the Unique Acceptance Procedure andwas approved by CENELEC as amendment A1 to EN 50117-2-5:2004 on 2007-12-01. The following dates were fixed: latest date by which the amendment has to be implementedat national level by publication of an identica
17、lnational standard or by endorsement (dop) 2008-12-01 latest date by which the national standards conflictingwith the amendment have to be withdrawn (dow) 2010-12-01 _ Foreword to amendment A2This document (EN 50117-2-5:2004/A2:2013) has been prepared by CLC/SC 46XA “Coaxial cables“ of CLC/TC 46X “C
18、ommunication cables“. The following dates are fixed: latest date by which this document has to be implemented atnational level by publication of an identical national standardor by endorsement(dop) 2014-07-01 latest date by which the national standards conflicting withthis document have to be withdr
19、awn(dow) 2016-07-01 Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This standard covers the Principle Elements of the Safety Objectiv
20、es for Electrical Equipment Designed for Use within Certain Voltage Limits (LVD - 2006/95/EC). BS EN 50117-2-5:2004+A2:2013EN 50117-2-5:2004+A2:2013 (E)Page 2Contents 1Scope 42Normative references . 43Definitions. 44Requirements for cable construction. 54.1 General.54.2 Inner conductor.54.3 Dielectr
21、ic.54.4 Outer conductor or screen.54.5 Filling compounds54.6 Moisture barriers.54.7 Wrapping layers 54.8 Sheath.54.9 Metallic protection .64.10 Cable integral suspension strand (Messenger wire)64.11 Oversheath64.12 Fauna proofing64.13 Chemical and/or environmental proofing64.14 Cable identification6
22、4.14.1 Sheath marking .64.14.2 Labelling65Tests for completed cables 75.1 Electrical tests.75.1.1 Low-frequency and D.C. electrical measurements75.1.2 High-frequency electrical and transmission measurements.75.2 Mechanical tests95.3 Environmental tests.115.4 Fire performance test methods .12Table 1
23、Low-frequency and D.C. electrical measurements7Table 2 High-frequency electrical and transmission measurements.7Table 4 Environmental tests.116Cable types .12Table 3 Mechanical tests9Table 6 Drop cable types Dimensions and ratings . 12Table deleted# $BS EN 50117-2-5:2004+A2:2013 EN 50117-2-5:2004+A2
24、:2013 (E)Page 31 Scope This European Standard relates to EN 50117-1 and should be read in conjunction with this genericspecification. This specification applies to outdoor drop cables foruse in cabled distribution systemsoperating at temperature between -40 C and +70 C 1) and at frequencies between
25、5 MHz and 3 000 MHz and complying with the requirements of EN 50083. The purpose of this European Standard is to specify the applicable test methods and requirements forthe electrical, mechanical, environmental and fire performance of the cables. 2 Normativereferences The following referenced docume
26、nts are indispensable for the application of this document. For dated references, only the edition cited applies. For undated refer ences, the latest edition of the referenced document (including any amendments) applies.EN 50083 series Cable networks for television signals, sound signals and interac
27、tive servicesEN 50117-1 Coaxial cables Part 1: Generic specification EN 50289-1-6 Communication cables Specifications for test methods Part 1-6: Electrical testmethods Electromagnetic performance EN 50289-3-9 Communication cables Specifications for test methods Part 3-9: Mechanical test methods Bend
28、ing testsEN 50290-1-2 2) Communication cables Part 1-2: DefinitionsEN 50290-2-23 Communication cables Part 2-23: Common design rules and construction PE insulation EN 50290-2-24 Communication cables Part 2-24: Common design rules and construction PE sheathing EN 50290-2-25 Communication cables Part
29、2-25: Common design rules and construction Polypropylene insulation compoundsEN 50290-2-27 Communication cables Part 2-27: Common design rules and construction Halogen free flame retardant thermoplastic sheathing compoundsEN 50290-4-1 Communication cables Part 4-1: General considerations for the use
30、 of cables Environmental conditions and safety aspectsEN 62153-1-1 Metallic telecommunication cable test methods Part 1-1: Electrical Measurement of the pulse/step return loss in the frequency domain using the Inverse Discrete Fourier Transformation (IDFT) (IEC 62153-1-1)IEC 61196-1-115 2) Coaxial c
31、ommunication cables Part 1-115: Electrical test methods Test forpulse return loss (regularity of impedance)3 Definitions For the purposes of this European Standard, the definitions of EN 50290-1-2 and EN 50117-1 apply.1) This value is valid for applications without ampacity only.2) At draft stage.!
32、The definition of a drop coaxial cable is one of use or intended use and application within the network rather than by specific constructional requirements of the cable itself. 3.1 drop cable coaxial cable which is used to connect from a) subscriber tap or a directional coupler to a system outlet, b
33、) subscriber tap to a subscriber splitter, c) subscriber splitter to a system outlet“EN 50117-1:2002/A2:2013 Coaxial cables Part 1: Generic specification#$BS EN 50117-2-5:2004+A2:2013EN 50117-2-5:2004+A2:2013 (E)Page 44 Requirements for cable construction 4.1 General Designing the cable, considerati
34、on should be paid to the maximum admissible current stated in the detail specification. It is assumed that the raise if temperature of the inner conductor when submitted to the maximumcurrent under nominal ambient conditions does not affect the mechanical and electrical properties of the cable (deta
35、ils are under study).4.2 InnerconductorThe conductor shall meet the requirements of Subclause 4.2 of EN 50117-1, and shall be solid or tube. Individual wires can be plain or metal coated. Dimensions shall be in accordance with the detailed specification. There shall be no joint made subsequent to th
36、e last drawing operation.4.3 Dielectric The dielectric material(s) shall be in accordance with Subclause 4.3 of EN 50117-1 and shall consist ofpolyolefin materials,with EN 50290-2-23 (polyethylene), EN 50290-2-25 (polypropylene) or any relevant part of EN 50290-2-XX. Dimensions shall be in accordanc
37、e with the detail specification.Unlessotherwise specified, the nominal diameter over the dielectric should be one of the preferred values, namely 2,9 mm, 3,7 mm, 4,8 mm and 7,2 mm.4.4Outer conductor or screen The construction and material of the outer conductor and/or screen shall be meet the requir
38、ements ofclause Subclause 4.4, itemsb), c), f) or g) of EN 50117-1. Where option b) is used, a double braid layer isrequired. Forbraid constructions or helically wound wires, the braid angle shall be between 15 and 45. The coverage factor shall be greater than or equal to 65 %, or, when the cable is
39、 provided with a metal foil, greater than or equal to 25 %. These values are also valid for cables with two bi-directional layers ofhelically wound wires.Dimensions shall be in accordance with the detailed specification.4.5 Filling compounds Not applicable 4.6 Moisture barriers Not applicable 4.7 Wr
40、apping layersNot applicable 4.8 SheathSheath material(s) shall meet the requirements of EN 50290-2-24 for PE sheaths or EN 50290-2-27 forhalogen free flame retardant materials.BS EN 50117-2-5:2004+A2:2013 EN 50117-2-5:2004+A2:2013 (E)Page 5Sheaths of cables used in aerial or external applications sh
41、all meet the requirement of the UV resistance test. The sheath shall also meet the requirements of Subclause 4.8 of EN 50117-1. Dimensions shall be in accordance with the detailed specification.4.9 Metallic protection Not applicable 4.10 Cable integral suspension strand (Messenger wire)When applicab
42、le messenger wires shall be in accordance with Subclause 4.10 of EN 50117-1. When applicable messenger wires shall meet the requirements of the relevant detail specification. 4.11 OversheathNot applicable 4.12 Fauna proofing Not applicable 4.13 Chemical and/or environmental proofing Not applicable 4
43、.14 Cable identificationCable identification shall be in accordance with Subclause 4.14 of EN 50117-1. 4.14.1 SheathmarkingSheath marking shall be achieved as a non-degradable print containing the following minimuminformation: designation of the cable; attenuation value (in dB/100 m at 800 MHz, roun
44、ded); screening class; Euro-class; name of supplier.EXAMPLEEN 50117-2-5 21 Class B Euro-class C 4.14.2 LabellingUnless otherwise specified in the detail specification drums or coils shall be provided with a label with a non-degradable print containing the following minimum information: designation o
45、f the cable; attenuation value (in dB/100 m at 800 MHz, rounded); screening class; Euro-class; ! NOTE The Construction Products Directive (CPD) will define classes for the fire performance of cables. As long as therequired.“CPD is under consideration and fire performance classes (Euroclasses) are no
46、t defined, sheath marking with Euroclass is notBS EN 50117-2-5:2004+A2:2013EN 50117-2-5:2004+A2:2013 (E)Page 6 name of supplier; batch part number; length of cable. EXAMPLEEN 50117-2-5 21 Class B Euro -class C 03/04 543m5 Tests for completed cables When tested in accordance with the requirements of
47、EN 50117-1, the r equirements given below shall apply.5.1 Electrical tests 5.1.1 Low-frequency and D.C. electrical measurements Table 1 Low-frequency and D.C. electrical measurements EN 50117-1 Subclause nParameter Requirements/Remarks 5.1.1.1 Conductor resistance Applicable, value in accordance wit
48、h the detail specification 5.1.1.2 Dielectric strength 2 kV D.C. or 1,5 kV A.C. for 1 min 5.1.1.3 Insulation resistance 10 4 M x km5.1.1.4 Mutual capacitance When required, in accordance with the detail specification 5.1.1.5 Voltage test of sheath 2,5 kV A.C. or 3,75 kV D.C., unless otherwise specif
49、ied in the relevant detail specification. Test in accordance with EN 50289-1-X a5.1.1.6 Discharge (corona) testNot applicable 5.1.1.7 Voltage proof Not applicable 5.1.1.8 Power rating Not applicable a Test procedure is under consideration by CLC/SC 46XA.5.1.2 High-frequency electrical and transmission measurements Table 2 High-frequency electrical and transmission measurements EN 50117-1 Subclause nParameter Requirements/Remarks 5.1.2.